Search NASA⌕ Search

Engineering topics

Kostin, R.

Publications and source records attributed to Kostin, R..

Beam Dynamics simulations for ERDC project -- SRF linac for industrial use

Compact conductively cooled SRF industrial linacs can provide unique parameters of the electron beam for industrial applications. (up to 10MeV, 1MW). For ERDC project we designed normal conducting RF injector with thermal RF gridded gun integrated in first cell of multi-cell cavities. For design of the RF gun we used MICHELLE software to simulate and optimize parameters of the beam. Output file was converted to ASTRA format and most beam dynamic simulations in multi-cell normal conducting cavity and cryomodule were performed by using ASTRA software. For cross-checking we compare results of MICHELLE and AS-TRA in first few cells. At the end of injector beam reach ~250keV energy which allow to trap bunch in acceleration regime without losses in TESLA like 1.3 GHz cavity. Short solenoid at the end of injector allow to regulate transverse beam size in cryomodule to match beam to extraction system and also reduce charge losses in accelerator.

43 PARTICLE ACCELERATORS↗

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.↗

Development of a liquid-helium free cryogenic sample holder with mK temperature control for autonomous electron microscopy

The automated and autonomous cryogenic transmission electron microscopy (Cryo-EM) demands a sample holder capable of maintaining temperatures below 10 K with precise control, long holding times, and minimal helium use. Rising to this challenge, we initiated an ambitious project to develop a novel closed-cycle cryocooler-based cryogenic sample holder that operates without the use of liquid helium and the consumption of gaseous helium. Here, this article presents the design, construction, and experimental testing of the initial prototype, which achieves an ultimate temperature of 5.6 K with exceptional stability close to 1mK, while providing a wide temperature control range from 295 K to 5.6 K, marking a clear advancement in cryo-EM holder development. While the prototype was not designed for atomic resolution imaging and thus lacks a sturdy support system to mitigate mechanical vibrations from the cryocooler's pulsed tube, this innovative approach successfully demonstrates proof of concept. It offers unprecedented capabilities for state-of-the-art cryogenic microscopy and microanalysis in materials and biological sciences.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Progress and Challenges in Traveling-Wave SRF cavity development at Fermilab

Traveling-wave (TW) technology can push the accelerator field gradient of niobium SRF cavity to 70MV/m or higher beyond the limit of 50~60MV/m in Standing-wave (SW) technology. The early stages of TW SRF cavity developments had been funded by several SBIR grants to Euclid Techlabs and completed in collaboration with Fermilab through a 1-cell prototype and a proof-of-principle 3-cell TW cavity. The TW resonance excitation in the 3-cell TW cavity at 2K was demonstrated through the low power RF test in early 2024. A high-power test of the 3-cell in TW mode being prepared. To advance a design and technology to fabricate a novel high gradient TW SRF cavity, FNAL proposed a half-meter TW RF design and R&Ds to realize that are in progress. Here we will report the recent progress in the 3-cell TW cavity and the challenges towards a half-meter scale TW cavity.

Furuta, F.↗

Development of 3-cell Traveling Wave SRF Cavity

Traveling wave SRF cavity is a new technology and requires a multi-stage process for development. Conceptual designs have been proposed to adopt TW resonance in an SRF cavity The early stages of developments have been funded by several SBIR grants to Euclid Techlabs which were completed in collaboration with Fermilab. A 3-cell proof-of-principle TW cavity was fabricated as part of that and demonstrated the TW resonance excitation at room temperature. A TW resonance control tuner for the 3-cell was also fabricated and the preliminary tests were performed. Now, the 3-cell cavity is being processed and prepared for the first cryogenic testing.

43 PARTICLE ACCELERATORS↗

DEMONSTRATION OF TWICE REDUCED LORENTZ FORCE DETUNING IN SRF CAVITY BY COPPER COLD SPRAYING

Superconducting RF (SRF) cavities usually are made of thin-wall high RRR Niobium that is susceptible to Lorentz Force Detuning (LFD) ? cavity deformation phenomena caused by high magnitude RF fields. This type of deformation can be mitigated by using an additional copper layer deposited on the outer surface of the cavity. In this paper, we present both modeling results and experimental data of high gradient test of an SRF cavity at cryogenic temperatures. It was demonstrated that LFD can be significantly reduced (factor of two) by the copper cold spray reinforcement without sacrificing cavity flexibility for tuning. We also present a finite-element model that allows us to confirm our experimental results and optimize the cavity geometry for LFD reduction with incorporated coupled RF, structural and thermal modules.

Kostin, R.↗