Search NASA⌕ Search

Engineering topics

Kravitz, S.

Publications and source records attributed to Kravitz, S..

At least 19 records

Constraints on Covariant Dark-Matter–Nucleon Effective Field Theory Interactions from the First Science Run of the LUX-ZEPLIN Experiment

The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA. We report on the results of a relativistic extension to the nonrelativistic effective field theory (NREFT) from a 5.5 t fiducial mass and 60 live days of exposure. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the weakly interacting massive particle which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0 keV nr to 270 keV nr , we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Probing the scalar WIMP-pion coupling with the first LUX-ZEPLIN data

Weakly interacting massive particles (WIMPs) may interact with a virtual pion that is exchanged between nucleons. This interaction channel is important to consider in models where the spin-independent isoscalar channel is suppressed. Using data from the first science run of the LUX-ZEPLIN dark matter experiment, containing 60 live days of data in a 5.5 tonne fiducial mass of liquid xenon, we report the results on a search for WIMP-pion interactions. We observe no significant excess and set an upper limit of 1.5 × 10$^{−46}$ cm$^{2}$ at a 90% confidence level for a WIMP mass of 33 GeV/c$^{2}$ for this interaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The data acquisition system of the LZ dark matter detector: FADR

The Data Acquisition System (DAQ) for the LUX-ZEPLIN (LZ) dark matter detector is described. The signals from 745 PMTs, distributed across three subsystems, are sampled with 100-MHz 32-channel digitizers (DDC-32s). A basic waveform analysis is carried out on the on-board Field Programmable Gate Arrays (FPGAs) to extract information about the observed scintillation and electroluminescence signals. This information is used to determine if the digitized waveforms should be preserved for offline analysis. The system is designed around the Kintex-7 FPGA. In addition to digitizing the PMT signals and providing basic event selection in real time, the flexibility provided by the use of FPGAs allows us to monitor the performance of the detector and the DAQ in parallel to normal data acquisition. Furthermore, the hardware and software/firmware of this FPGA-based Architecture for Data acquisition and Realtime monitoring (FADR) are discussed and performance measurements are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New constraints on ultraheavy dark matter from the LZ experiment

Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV / c 2 to a few TeV / c 2 . Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a reanalysis of the first science run of the LZ experiment, with an exposure of 0.9 tonne × yr , to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 10 17 GeV / c 2 . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First constraints on WIMP-nucleon effective field theory couplings in an extended energy region from LUX-ZEPLIN

Following the first science results of the LUX-ZEPLIN (LZ) experiment, a dual-phase xenon time projection chamber operating from the Sanford Underground Research Facility in Lead, South Dakota, USA, we report the initial limits on a model-independent nonrelativistic effective field theory describing the complete set of possible interactions of a weakly interacting massive particle (WIMP) with a nucleon. These results utilize the same 5.5 t fiducial mass and 60 live days of exposure collected for the LZ spin-independent and spin-dependent analyses while extending the upper limit of the energy region of interest by a factor of 7.5 to 270 keV. No significant excess in this high energy region is observed. Using a profile-likelihood ratio analysis, we report 90% confidence level exclusion limits on the coupling of each individual nonrelativistic WIMP-nucleon operator for both elastic and inelastic interactions in the isoscalar and isovector bases. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of dielectric breakdown in liquid xenon with XeBrA: The xenon breakdown apparatus

Maintaining the electric fields necessary for the current generation of noble liquid time projection chambers (TPCs), with drift lengths exceeding 1 m, requires a large negative voltage applied to their cathode. Delivering such high voltage is associated with an elevated risk of electrostatic discharge and electroluminescence, which would be detrimental to the performance of the experiment. The Xenon Breakdown Apparatus (XeBrA) is a 5-l, high voltage test chamber built to investigate the contributing factors to electrical breakdown in noble liquids. Here, in this work, we present the main findings after conducting scans over stressed electrode areas, surface finish, pressure, and high voltage ramp speed in the medium of liquid xenon. Area scaling and surface finish were observed to be the dominant factors affecting breakdown, whereas no significant changes were observed with varying pressure or ramp speed. A general rise in both the anode current and photon rate was observed in the last 30 s, leading up to a breakdown, with a marked increase in the last couple of seconds. In addition, the position of breakdowns was reconstructed with a system of high-speed cameras and a moderate correlation with the Fowler–Nordheim field emission model was found. Tentative evidence for bubble nucleation being the originating mechanism of breakdown in the liquid was also observed. We deem the results presented in this work to be of particular interest for the design of future, large TPCs, and practical recommendations are provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scintillation yield from electronic and nuclear recoils in superfluid He 4

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185~keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090~keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. As a result, we also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cosmogenic production of 37 Ar in the context of the LUX-ZEPLIN experiment

We estimate the amount of 37 Ar produced in natural xenon via cosmic-ray-induced spallation, an inevitable consequence of the transportation and storage of xenon on the Earth’s surface. We then calculate the resulting 37 Ar concentration in a 10-tonne payload (similar to that of the LUX-ZEPLIN experiment) assuming a representative schedule of xenon purification, storage, and delivery to the underground facility. Using the spallation model by Silberberg and Tsao, the sea-level production rate of 37 Ar in natural xenon is estimated to be 0.024 atoms/kg/day. Assuming the xenon is successively purified to remove radioactive contaminants in 1-tonne batches at a rate of 1 tonne/month, the average 37 Ar activity after 10 tons are purified and transported underground is 0.058 − 0.090 𝜇⁢Bq/kg, depending on the degree of argon removal during above-ground purification. Such cosmogenic 37 Ar will appear as a noticeable background in the early science data, while decaying with a 35-day half-life. This newly noticed production mechanism of 37 Ar should be considered when planning for future liquid-xenon-based experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

Transforming U.S. Particle Physics Education: A Snowmass 2021 Study

The pursuit of knowledge in particle physics requires constant learning. As new tools become available, new theories are developed, and physicists search for new answers with ever-evolving methods. However, it is the case that formal educational systems serve as the primary training grounds for particle physicists. Graduate school (and undergraduate school to a lesser extent) is where researchers learn most of the technical skills required for research, develop scientific problem-solving abilities, learn how to establish themselves in their field, and begin developing their career. It is unfortunate, then, that the skills gained by physicists during their formal education are often mismatched with the skills actually required for a successful career in physics. We performed a survey of the U.S. particle physics community to determine the missing elements of graduate and undergraduate education and to gauge how to bridge these gaps. In this contributed paper, part of the 2021-22 Snowmass Community Planning Exercise, we report the results of this survey. We also recommend several specific community actions to improve the quality of particle physics education; the "community" here refers to physics departments, national labs, professional societies, funding agencies, and individual physicists.

Bitter, O.↗

Snowmass2021 Cosmic Frontier: The landscape of low-threshold dark matter direct detection in the next decade

The search for particle-like dark matter with meV-to-GeV masses has developed rapidly in the past few years. We summarize the science case for these searches, the recent progress, and the exciting upcoming opportunities. Funding for Research and Development and a portfolio of small dark matter projects will allow the community to capitalize on the substantial recent advances in theory and experiment and probe vast regions of unexplored dark-matter parameter space in the coming decade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The EXO-200 detector, part II: auxiliary systems

The EXO-200 experiment searched for neutrinoless double-beta decay of 136 Xe with a single-phase liquid xenon detector. It used an active mass of 110 kg of 80.6%-enriched liquid xenon in an ultra-low background time projection chamber with ionization and scintillation detection and readout. Here, this paper describes the design and performance of the various support systems necessary for detector operation, including cryogenics, xenon handling, and controls. Novel features of the system were driven by the need to protect the thin-walled detector chamber containing the liquid xenon, to achieve high chemical purity of the Xe, and to maintain thermal uniformity across the detector.

47 OTHER INSTRUMENTATION↗

Measurement of the angular distribution of wavelength-shifted light emitted by TPB

We present measurements of the angular distribution of re-emitted light from tetraphenyl butadiene thin films when exposed to 128 nm light, which is the peak of the liquid Argon (LAr) scintillation spectrum, in vacuum. Films ranging from 250 nm to 5.5 μm in thickness are measured. All films were fabricated by evaporation deposition on ultraviolet transmitting (UVT) acrylic substrates. Preliminary comparisons of the angular distribution to that produced by a detailed Monte Carlo model are also presented. The current shortcomings of the model are discussed and future plans briefly outlined.

47 OTHER INSTRUMENTATION↗

Projected sensitivity of the LUX-ZEPLIN experiment to the two-neutrino and neutrinoless double $\beta$ decays of $^{134}$Xe

The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of 134 Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of 134 Xe, for which xenon detectors enriched in 136 Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7 x 10 24 years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7 x 10 23 years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3 x 10 24 years at 90% CL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projected sensitivities of the LUX-ZEPLIN experiment to new physics via low-energy electron recoils

LUX-ZEPLIN is a dark matter detector expected to obtain world-leading sensitivity to weakly-interacting massive particles interacting via nuclear recoils with a ∼7-tonne xenon target mass. This paper presents sensitivity projections to several low-energy signals of the complementary electron recoil signal type: 1) an effective neutrino magnetic moment, and 2) an effective neutrino millicharge, both for 𝑝⁢𝑝-chain solar neutrinos, 3) an axion flux generated by the Sun, 4) axionlike particles forming the Galactic dark matter, 5) hidden photons, 6) mirror dark matter, and 7) leptophilic dark matter. World-leading sensitivities are expected in each case, a result of the large 5.6 t 1000 d exposure and low expected rate of electron-recoil backgrounds in the <100 keV energy regime. A consistent signal generation, background model and profile-likelihood analysis framework is used throughout.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗