Characterization of Open Circuit Voltage and Capacity as a Function of Time

It is noted from the data presented that Li/BCX cells lose approximately 8% of their rated capacity in the first 2 months of storage. After this period of time, little difference is noted in the average realized capacity; however, a significant increase in the range is observed. Over the same period of time the OCV falls at a rate of 0.02V per 1,000 hours. After a period of 8,000 hours the OCV appears stabilize at a value of approximately 3.75V. This may be related to changes in Cl2 concentration due to self-discharge or other reactions. These data indicate that no correlation exists between the reduced open circuit voltage and the realized capacity.

Krehl, P. W.↗

Safety tests

The ovedischarge test program and results for double A and D lithium cells are discussed. Temperature increases and sparking responses are dressed.