Search NASA⌕ Search

Engineering topics

Krejny, Megan

Publications and source records attributed to Krejny, Megan.

The Gray Needle: Large Grains in the HD 15115 Debris Disk from LBT*/PISCES/K s and LBTIi+/LMIRcam/L(prime) Adaptive Optics Imaging

We present diffraction-limited K s band and L(prime) adaptive optics images of the edge-on debris disk around the nearby F2 star HD 15115, obtained with a single 8.4 m primary mirror at the Large Binocular Telescope. At the Ks band, the disk is detected at signal-to-noise per resolution element (SNRE) approx. 3-8 from approx. 1 to 2".5 (45-113 AU) on the western side and from approx. 1". 2 to 2".1 (63-90 AU) on the east. At L the disk is detected at SNRE approx. 2.5 from approx. 1 to 1".45 (45-90 AU) on both sides, implying more symmetric disk structure at 3.8 micrometers. At both wavelengths the disk has a bow-like shape and is offset from the star to the north by a few AU. A surface brightness asymmetry exists between the two sides of the disk at the Ks band, but not at L(prime). The surface brightness at the K s band declines inside 1"(approx. 45 AU), which may be indicative of a gap in the disk near 1".The K s − L(prime) disk color, after removal of the stellar color, is mostly gray for both sides of the disk. This suggests that scattered light is coming from large dust grains, with 3-10 micrometers sized grains on the east side and 1-10 micrometers dust grains on the west. This may suggest that the west side is composed of smaller dust grains than the east side, which would support the interpretation that the disk is being dynamically affected by interactions with the local interstellar medium.

signal-to-noise↗

The Hertz/VPM Polarimeter: Design and First Light Observations

We present first results of Hertz/VPM, the first submillimeter polarimeter employing the dual Variable-delay Polarization Modulator (dual-VPM). This device differs from previously used polarization modulators in that it, operates in translation rather than mechanical rotation. We discuss the basic theory behind this device, and its potential advantages over the commonly used half wave plate (HFVP). The dual-VPM was tested both at the Submillimeter Telescope Observatory (SMTO) and in the lab. In each case we present a detailed description of the setup. We discovered nonideal behavior in the system. This is at least in part due to properties of the VPM wire grids (diameter, spacing) employed in our experiment. Despite this, we found that the dual-VPM system is robust, operating with high efficiency and low instrumental polarization. This device is well suited for air and space-borne applications.

Krejny, Megan↗