Publications and source records attributed to Kremeyer, T..

Observation of impurity accumulation and its compatibility with high plasma performance in W7-X

At the W7-X stellarator, the bolometer system has measured an intensive radiation zone in the inner plasma region (at a normalized radius $ρ$ ~ 0.3–0.4) in the hydrogen plasma generated by electron cyclotron resonance heating; it differs from the normal plasma radiation distribution with an edge-localized emission zone. Spectroscopic diagnostics have recorded high-Z elements such as iron. This phenomenon happens in the plasma phases after gas supply turn-off, which results in all impurity relevant diagnostic signals increasing for several seconds. Despite the enhancement of the core radiation, the plasma energy confinement is improved. A transport analysis shows that this impurity radiation behavior is associated with a low diffusion coefficient ($D$~ 0.02 m 2 s -1 ) and a reversal of the convection around the radial position of the emission peak, which, under normal conditions, separates the zones of outward convection in the central (|$V$| ~ 0.1 m s -1 ) and inward convection in the outer region (|$V$| ~ 0.3 m s -1 ). An impurity accumulation around this radial position has been identified. The transport coefficients obtained are comparable with the theoretical predictions of collisional impurity transport. In the plasma phases studied, both impurity and energy confinement are enhanced. The mechanism responsible for the improvement is believed to be a reduction of micro-instabilities associated with the observed steepening of the density profile, initiated by a low edge plasma density (<1.0 × 10 19 m -3 ) after switching off the gas fueling. The normalized temperature and density gradients fulfil the condition for the suppression of ITG turbulence.

suppression of ITG turbulence↗

First attempt to quantify W7-X island divertor plasma by local experiment-model comparison

As a complement to our recent work, which focused on understanding the basic detachment physics and general experimental and numerical trends observed in the W7-X island divertor, this paper compares EMC3-Eirene simulation results with different local diagnostics, including IR cameras, Langmuir probes, H α -cameras, and Thomson scattering. The main purposes are to (1) justify the simulation setup in the previous work, (2) identify the application limitations of the current EMC3-Eirene model, (3) verify the consistency of different diagnostics, and (4) isolate the main geometric and physical effects that need to be prioritized in further developing the EMC3-Eirene code and improving diagnostic capabilities. It turns out that the current version of the EMC3-Eirene code (without drifts) is not yet able to quantitatively reproduce all selected local measurements simultaneously under the current experimental conditions (in particular, the existence of error fields). Nevertheless, it can be shown that within a reasonable range of variation in magnetic configuration, cross-field transport, and SOL plasma state in the modeling, a region of overlap between the numerical results and the local measurements can be established. More accurate model-experiment comparisons will require clarification of error fields, implementation of drifts in EMC3, and improvement of diagnostic capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.