Dataset for SO2, SO3, H2SO4 and H2O infrared absorption spectra at 300° C and 350° C temperatures
Not Available
Engineering topics
Publications and source records attributed to Kriesel, Jason.
Not Available
Explore the source record for details and available documents.
Mid infrared absorption spectra of sulfuric acid (H2SO4), sulfur trioxide (SO3), sulfur dioxide (SO2), and water (H2O) were collected in a high temperature gas cell operating at either 300C or 350C. The spectra were collected using tunable external cavity quantum cascade lasers (ECQCLs) tuning, which were capable of operating over the wavelength range from approximately 7 microns to 9 microns, where H2SO4 and SO3 have their strongest absorption features. The spectra can be used as a library for developing gas sensors.
Explore the source record for details and available documents.
Capillary Absorption Spectroscopy (CAS) is a relatively new analytical technique for performing stable isotope analysis. Here, we demonstrate the utility of CAS by recording and quantifying variation in 13C in controlled and biologically relevant applications. We calibrated CAS system response to increased 13CO2, with an observed ~4‰ increase in measured Δ13C for each 0.03 ppm shift in 13CO2 concentration. We leveraged this calibration to quantify rates of biogeochemical processes using a 13C tracer. For example, we monitored microbial respiration of 13C-glucose within an agricultural soil at 10 s quantification intervals and results demonstrated 8.6% ± 0.4 of added glucose was converted to 13CO2 within 1.5 h of incubation. We expanded the demonstration by adapting a rhizobox to permit continuous monitoring of 13CO2 in a soil (as distinct from plant) headspace to track the timing and quantify respiration rates of fresh plant photosynthate and observed a 3.5 h delay between plant exposure to a13CO2 tracer and the first signs of respiration by soil biota. These experiments highlight CAS is effective in producing high temporal resolution quantification of 13CO2 and demonstrate potential applications.
We present results from field testing of a new, innovative sensor developed to measure SO3/H2SO4 continuously and in real time at a coal-fired power plant. The system utilizes the sensitivity, specificity, and real-time capabilities of mid-infrared (Mid-IR) laser-based sensor technology, along with a heated, close-coupled cell mounted directly to a power plant duct. Measurements were made by the laser sensor over a 2-day period and compared to results from the accepted method, EPA 8A, which requires a 30-minute collection, labor intensive processing, and off-site analysis at a lab. In contrast to the condensation method, the laser sensor continuously samples flue gas and reports measurements of the concentration of SO3/H2SO4, SO2 ever second with unattended operation. This initial demonstration proved the sensor concept and paves the way for its use for optimizing sorbent injection used to neutralize SO3/H2SO4. Optimized sorbent injection will enable significant cost savings associated with efforts to mitigate the presence and effects of SO3/H2SO4 such as “Blue Plume”, air heater fouling, and duct corrosion. In particular, the real-time, actionable information will enable better control of additive injection in flex conditions and variable fuels.
Explore the source record for details and available documents.