Search NASA⌕ Search

Engineering topics

Kristo, M. J.

Publications and source records attributed to Kristo, M. J..

Development of small particle speciation for nuclear forensics by soft X-ray scanning transmission spectromicroscopy

Synchrotron radiation spectromicroscopy provides a combination of submicron spatial resolution and chemical sensitivity that is well-suited to analysis of heterogeneous nuclear materials. The chemical and physical characteristics determined by scanning transmission X-ray microscopy (STXM) are complementary to information obtained from standard radiochemical analysis methods. In addition, microscopic quantities of radioactive material can be characterized rapidly by STXM with minimal sample handling and intrusion, especially in the case of particulate materials. The STXM can accommodate a diverse range of samples including wet materials, complex mixtures, and small quantities of material contained in a larger matrix. In these cases, the inventory of species present in a sample is likely to carry information on its process history; STXM has the demonstrated capability to identify contaminants and sample matrices. Operating in the soft X-ray regime provides particular sensitivity to the chemical state of specimens containing low-Z materials, via the K-edges of light elements. In this paper, recent developments in forensics-themed spectromicroscopy, sample preparation, and data acquisition methods at the Molecular Environmental Science Beamline 11.0.2 of the Advanced Light Source are described. Results from several initial studies are presented, demonstrating the capability to identify the distribution of the species present in heterogeneous uranium-bearing materials. Finally, future opportunities for STXM forensic studies and potential methodology development are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiochronometry in the CMX-4 Exercise-Draft

In a recent international exercise, 10 international nuclear forensics laboratories successfully performed radiochronometry on 3 low-enriched uranium oxide samples, providing 12 analytical results using 3 different parent-daughter pairs serving as independent chronometers. The vast majority of the results were consistent with one another and consistent with the known processing history of the materials. In general, for these particular samples, mass spectrometry gave more accurate and more precise analytical results than decay counting measurements. In addition, the concordance of the 235 U- 231 Pa and 234 U- 230 Th chronometers confirmed the validity of the age dating assumption, increasing our confidence in the resulting conclusions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Report on Small Particle Speciation for Forensics Analysis by Soft X-ray Scanning Transmission X-ray Microscopy

Materials of interest for nuclear forensic science are often highly heterogeneous, containing complex mixtures of actinide compounds in a wide variety of matrices. Scanning transmission X-ray microscopy (STXM) is ideally suited to study such materials, as it can be used to chemically image specimens by acquiring X-ray absorption near-edge spectroscopy (XANES) data with 25 nm spatial resolution. In particular, STXM in the soft X-ray synchrotron radiation regime (approximately 120 – 2000 eV) can collect spectroscopic information from the actinides and light elements in a single experiment. Thus, STXM combines the chemical sensitivity of X-ray absorption spectroscopy with high spatial resolution in a single non-destructive characterization method. This report describes the application of STXM to a broad range of nuclear materials. Where possible, the spectroscopic images obtained by STXM are compared with information derived from other analytical methods, and used to make inferences about the process history of each material. STXM measurements can yield information including the morphology of a sample, “elemental maps” showing the spatial distribution of major chemical constituents, and XANES spectra from localized regions of a sample, which may show spatial variations in chemical composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Technical Report on the Behavior of Trace Elements, Stable Isotopes, and Radiogenic Isotopes During the Processing of Uranium Ore to Uranium Ore Concentrate

The goals of this SP-1 effort were to understand how isotopic and elemental signatures behave during mining, milling, and concentration and to identify analytes that might preserve geologic signatures of the protolith ores. The impurities that are preserved through the concentration process could provide useful forensic signatures and perhaps prove diagnostic of sample origin.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Australian Nuclear Science & Technology Organization (ANSTO) Interdicted Samples: 1-Week Report

Categorization is complete and characterization is well underway. Samples FSC 11-3-1 (NSR-F-270409-01) and FSC-11-3-2 (NSR-F-270409-02) are depleted uranium powders of moderate purity (~71-80 % U). Both were depleted to ~0.41-0.44% 235 U. Both samples have easily detectable amounts of 236 U, as well as 232 U at low levels. Samples FSC-11-3-1 and FSC-11-3-2 appear to be tails from an enrichment facility that used reprocessed U as part of its feed-stock. The U isotopic compositions of the two samples, while similar, differ outside of analytical uncertainty, suggesting that these samples came from different lots of material. Sample FSC-11-3-3 is indistinguishable from a natural uranium ore concentrate (~78% U) of moderate purity. Two anomalous objects (11-3-1-4 and 11-3-2-5) were found in the material during aliquoting, but have not been further analyzed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nuclear Forensics International Technical Working Group (ITWG) Round Robin #3: 24-Hour Report

Categorization is complete. Both samples are weapons-usable, highly enriched uranium with a 235 U isotopic abundance of 94 ± 2 % (1-standard deviation). Both samples are solid and pin-shaped, apparently metallic, but with a slightly oxidized appearance. Both samples are approximately 3 mm in thickness, 18 mm in length, but trapezoidal in cross-section (the short ends are 5 & 3 mm for Sample A and 6 & 4 mm Sample B). There is no information available yet that indicates whether the samples were from different sources. The current analytical plan calls for division of the solid samples into 4 pieces: one for radiochemical analysis, one for mass spectrometry analysis, one for metallurgical analysis, and one for archiving. However, the size and strength of these solid pieces could prove challenging to section in a manner consistent with nuclear forensics best-practices, including safety and contamination prevention.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗