Search NASA⌕ Search

Engineering topics

Krygier, A.

Publications and source records attributed to Krygier, A..

Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)

High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. Here, in this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.

36 MATERIALS SCIENCE↗

Shock compression experiments using the DiPOLE 100-X laser on the high energy density instrument at the European x-ray free electron laser: Quantitative structural analysis of liquid Sn

X-ray free electron laser (XFEL) sources coupled to high-power laser systems offer an avenue to study the structural dynamics of materials at extreme pressures and temperatures. The recent commissioning of the DiPOLE 100-X laser on the high energy density (HED) instrument at the European XFEL represents the state-of-the-art in combining x-ray diffraction with laser compression, allowing for compressed materials to be probed in unprecedented detail. Here, we report quantitative structural measurements of molten Sn compressed to 85(5) GPa and ~3500 K. The capabilities of the HED instrument enable liquid density measurements with an uncertainty of ~1% at conditions which are extremely challenging to reach via static compression methods. We discuss best practices for conducting liquid diffraction dynamic compression experiments and the necessary intensity corrections which allow for accurate quantitative analysis. We also provide a polyimide ablation pressure vs input laser energy for the DiPOLE 100-X drive laser which will serve future users of the HED instrument.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized x-ray emission from 10 ns long germanium x-ray sources at the National Ignition Facility

This study investigates methods to optimize quasi-monochromatic, ~10 ns long x-ray sources (XRS) for time-resolved x-ray diffraction measurements of phase transitions during dynamic laser compression measurements at the National Ignition Facility (NIF). To support this, we produce continuous and pulsed XRS by irradiating a Ge foil with NIF lasers to achieve an intensity of 2 × 10 15 W/cm 2 , optimizing the laser-to-x-ray conversion efficiency. Our x-ray source is dominated by Ge He-α line emission. Here, we discuss methods to optimize the source to maintain a uniform XRS for ~10 ns, mitigating cold plasma and higher energy x-ray emission lines.

47 OTHER INSTRUMENTATION↗

A new class of variable-radii diffraction optics for high-resolution x-ray spectroscopy at the National Ignition Facility (invited)

A new class of crystal shapes has been developed for x-ray spectroscopy of point-like or small (a few mm) emission sources. These optics allow for dramatic improvement in both achievable energy resolution and total throughput of the spectrometer as compared with traditional designs. This class of crystal shapes, collectively referred to as the Variable-Radii Spiral (VR-Spiral), utilize crystal shapes in which both the major and minor radii are variable. A crystal using this novel VR-Spiral shape has now been fabricated for high-resolution Extended X-ray Absorption Fine Structure (EXAFS) experiments targeting the Pb-L 3 (13.0 keV) absorption edge at the National Ignition Facility. The performance of this crystal has been characterized in the laboratory using a microfocus x-ray source, showing that high-resolution high-throughput EXAFS spectra can be acquired using this geometry. Importantly, these successful tests show that the complex three-dimensional crystal shape is manufacturable with the required precision needed to realize the expected performance of better than 5 eV energy resolution while using a 30 mm high crystal. An improved generalized mathematical form for VR-Spiral shapes is also presented allowing improved optimization as compared to the first sinusoidal-spiral based design. Finally, this new formulation allows VR-Spiral spectrometers to be designed at any magnification with optimized energy resolution at all energies within the spectrometer bandwidth.

47 OTHER INSTRUMENTATION↗

Optimized continuum x-ray emission from laser-generated plasma

We study continuum x-ray emission from hot plasma at the National Ignition Facility (NIF). We find that the x-ray yield in the multi-keV photon energy range is larger in Ti than in Ag or Au. This apparent paradox is due to Ti K-shell vacancies generated by the extraordinary energy density achieved by the NIF lasers. This is supported by direct observations of large continuum enhancement above the Ti K-series limit due to both free–bound (recombination) emission and strong Ly α (H-like) emission. Detailed calculations agree well with our measurements and support our conclusions. <!--/abstract content--><!--fulltext content--> X-ray emission from matter pervades the universe and plays an important role in the high-energy density (HED) regime (~10 5 J/cm 3 ). For example, the emission and absorption of x-rays controls the thermal state and evolution of stellar interiors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Foil backlighter development at the OMEGA laser facility for extended x-ray absorption fine structure experiments

Extended x-ray absorption fine structure (EXAFS) measurements require a bright and continuous x-ray source and a detection system with high spectral resolution to capture the modulations of the absorption coefficient above the material absorption edge. When performing EXAFS measurements under laser-driven dynamic compression, it is hence critical to optimize the backlighter x-ray emission. In this study, a series of experiments has been conducted at the OMEGA laser facility to characterize titanium (Z = 22), iron (Z = 26), germanium (Z = 32), molybdenum (Z = 42), silver (Z = 47), and gold (Z = 79) foil backlighters irradiated with 3 kJ–12 kJ of laser energy. The spectra have been recorded using a dual crystal spectrometer (DCS), a two-channel transmission spectrometer covering 11 keV–45 keV and 19 keV–90 keV energy bands. The DCS has been calibrated so that the spectral intensities can be compared between different campaigns.

47 OTHER INSTRUMENTATION↗

Using simultaneous x-ray diffraction and velocity interferometry to determine material strength in shock-compressed diamond

We determine the strength of laser shock-compressed polycrystalline diamond at stresses above the Hugoniot elastic limit using a technique combining x-ray diffraction from the Linac Coherent Light Source with velocity interferometry. X-ray diffraction is used to measure lattice strains, and velocity interferometry is used to infer shock and particle velocities. These measurements, combined with density-dependent elastic constants calculated using density functional theory, enable determination of material strength above the Hugoniot elastic limit. Furthermore, our results indicate that diamond retains approximately 20 GPa of strength at longitudinal stresses of 150–300 GPa under shock compression.

36 MATERIALS SCIENCE↗

Extreme Hardening of Pb at High Pressure and Strain Rate

We study the high-pressure strength of Pb and Pb-4wt%Sb at the National Ignition Facility. We measure Rayleigh-Taylor growth of preformed ripples ramp compressed to ~400 GPa peak pressure, among the highest-pressure strength measurements ever reported on any platform. We find agreement with 2D simulations using the Improved Steinberg-Guinan strength model for body-centered-cubic Pb; the Pb-4wt%Sb alloy behaves similarly within the error bars. Here, the combination of high-rate, pressure-induced hardening and polymorphism yield an average inferred flow stress of ~3.8 GPa at high pressure, a ~250-fold increase, changing Pb from soft to extremely strong.

36 MATERIALS SCIENCE↗

FY18 LLNL Experimental Programs at Omega

In Fiscal Year 2018 (FY18), Lawrence Livermore National Laboratory’s (LLNL’s) High Energy-Density Physics (HED) and Indirect Drive Inertial Confinement Fusion (ICF-ID) programs conducted numerous campaigns on the OMEGA and OMEGA-EP (EP) laser systems. This was the 20th year of National Lab collaborative experiments at OMEGA since the Nova Laser at LLNL shut down in 1999 [1], building upon prior collaborations. In FY18 overall, these LLNL programs led 465 target shots, with 283 shots using just the OMEGA laser system, 172 shots using just the EP laser system, and 10 Joint shots using both lasers together. Approximately 28% of the total number of shots (60 OMEGA shots and 71 EP shots) supported the Indirect Drive Inertial Confinement Fusion Campaign. The remaining 72% (223 OMEGA-only shots, 101 EP-only shots and 10 Joint shots) were dedicated to experiments for High-Energy-Density Physics. Highlights of the various HED and ICF-ID campaigns are summarized in the following reports. In addition to these experiments, LLNL Principal Investigators (PIs) led a variety of Laboratory Basic Science campaigns using OMEGA and EP, including 99 target shots using just OMEGA and 39 shots using just EP. The highlights of these are also summarized, following the ICF and HED campaigns. Overall, LLNL PIs led a total of 603 shots at LLE in FY 2018. In addition, LLNL PIs supported 47 NLUF shots on Omega and 31 NLUF shots on EP in collaboration with the academic community.

36 MATERIALS SCIENCE↗

Bremsstrahlung x-ray generation for high optical depth radiography applications on the National Ignition Facility [Bremsstrahlung x-ray generation for opacity radiography applications on the National Ignition Facility]

Here, we have tested a set of x-ray sources for use as probes of highly attenuating, laser-driven experiments on the National Ignition Facility (NIF). Unlike traditional x-ray sources that optimize for a characteristic atomic transition (often the n = 2 → n = 1 transition in ionized, He-like atoms), the design presented here maximizes the total photon flux by optimizing for intense, broadband Bremsstrahlung radiation. Three experiments were performed with identical targets, including a uranium x-ray source foil and a tungsten substrate with a narrow (25 μm wide) collimating slit to produce a quasi-1D x-ray source. Two experiments were performed using 12 beams from the NIF laser, each delivering approximately 46 kJ of laser energy but with different laser spatial profiles. This pair yielded similar temporal x-ray emission profiles, spatial resolution, and inferred hot electron temperature. A third experiment with only 6 beams delivering approximately 25 kJ produced a lower hot electron temperature and significantly lower x-ray flux, as well as poorer spatial resolution. The data suggest that laser pointing jitter may have affected the location and intensity of the emitting plasma, producing an emission volume that was not well centered behind the collimating slit and lower intensity than designed. However, the 12-beam design permits x-ray radiography through highly attenuating samples, where lower energy line-emission x-ray sources would be nearly completely attenuated.

47 OTHER INSTRUMENTATION↗

Developing a high-flux, high-energy continuum backlighter for extended x-ray absorption fine structure measurements at the National Ignition Facility

Extended X-ray absorption fine structure (EXAFS) spectroscopy is a powerful tool for in situ characterization of matter in the high energy density regime. An EXAFS platform is currently being developed on the National Ignition Facility. Development of a suitable X-ray backlighter involves minimizing the temporal duration and source size while maximizing spectral smoothness and brightness. One approach involves imploding a spherical shell, which generates a high-flux X-ray flash at stagnation. Furthermore we present results from a series of experiments comparing the X-ray source properties produced by imploded empty and Ar-filled capsules.

47 OTHER INSTRUMENTATION↗

Phase transition lowering in dynamically compressed silicon

Silicon, being one of the most abundant elements in nature, attracts wide-ranging scientific and technological interest. Specifically, in its elemental form, crystals of remarkable purity can be produced. One may assume that this would lead to silicon being well understood, and indeed, this is the case for many ambient properties, as well as for higher-pressure behaviour under quasi-static loading. However, despite many decades of study, a detailed understanding of the response of silicon to rapid compression—such as that experienced under shock impact—remains elusive. Here, we combine a novel free-electron laser-based X-ray diffraction geometry with laser-driven compression to elucidate the importance of shear generated during shock compression on the occurrence of phase transitions. We observe lowering of the hydrostatic phase boundary in elemental silicon, an ideal model system for investigating high-strength materials, analogous to planetary constituents. Furthermore, we unambiguously determine the onset of melting above 14 GPa, previously ascribed to a solid–solid phase transition, undetectable in the now conventional shocked diffraction geometry; transitions to the liquid state are expected to be ubiquitous in all systems at sufficiently high pressures and temperatures.

36 MATERIALS SCIENCE↗

FY17 LLNL Omega Experimental Programs

The Capseed campaign goal is to measure shock front velocity non-uniformities in Inertial Confinement Fusion (ICF) ablator materials and quantify the level of non-uniformity caused by intrinsic effects. This is done using the Omega High Resolution Velocimeter (OHRV) to obtain velocity maps of the optically reflecting shock front following release of the ablator material into either PMMA for the warm experiments or cryogenic deuterium for the cryo experiments. For the three half-days in FY17 the focus was twofold: complete measurements on the impact of oxygen heterogeneity and oxygen mitigation layers for glow discharge polymer (GDP), and begin measuring velocity non-uniformities on deep release from Be, GDP, and highdensity carbon (HDC) into D2 with improved velocity sensitivity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanometer-scale characterization of laser-driven compression, shocks, and phase transitions, by x-ray scattering using free electron lasers

In this paper, we study the feasibility of using small angle X-ray scattering (SAXS) as a new experimental diagnostic for intense laser-solid interactions. By using X-ray pulses from a hard X-ray free electron laser, we can simultaneously achieve nanometer and femtosecond resolution of laser-driven samples. This is an important new capability for the Helmholtz international beamline for extreme fields at the high energy density endstation currently built at the European X-ray free electron laser. We review the relevant SAXS theory and its application to transient processes in solid density plasmas and report on first experimental results that confirm the feasibility of the method. Finally, we present results of two test experiments where the first experiment employs ultra-short laser pulses for studying relativistic laser plasma interactions, and the second one focuses on shock compression studies with a nanosecond laser system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrafast observation of lattice dynamics in laser-irradiated gold foils

Here, we have observed the lattice expansion before the onset of compression in an optical-laser-driven target, using diffraction of femtosecond X-ray beams generated by the SPring-8 Angstrom Compact Free-electron Laser. The change in diffraction angle provides a direct measure of the lattice spacing, allowing the density to be calculated with a precision of ±1%. From the known equation of state relations, this allows an estimation of the temperature responsible for the expansion as <1000 K. The subsequent ablation-driven compression was observed with a clear rise in density at later times. This demonstrates the feasibility of studying the dynamics of preheating and shock formation with unprecedented detail.

36 MATERIALS SCIENCE↗

Experiment and simulation of novel liquid crystal plasma mirrors for high contrast, intense laser pulses

Here, we describe the first demonstration of plasma mirrors made using freely suspended, ultra-thin films formed dynamically and in-situ. We also present novel particle-in-cell simulations that for the first time incorporate multiphoton ionization and dielectric models that are necessary for describing plasma mirrors. Dielectric plasma mirrors are a crucial component for high intensity laser applications such as ion acceleration and solid target high harmonic generation because they greatly improve pulse contrast. We use the liquid crystal 8CB and introduce an innovative dynamic film formation device that can tune the film thickness so that it acts as its own antireflection coating. Films can be formed at a prolonged, high repetition rate without the need for subsequent realignment. High intensity reflectance above 75% and low-field reflectance below 0.2% are demonstrated, as well as initial ion acceleration experimental results that demonstrate increased ion energy and yield on shots cleaned with these plasma mirrors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗