Search NASA⌕ Search

Engineering topics

Kuban, Deborah A

Publications and source records attributed to Kuban, Deborah A.

A Comprehensive Comparison of IMRT and VMAT Plan Quality for Prostate Cancer Treatment

Purpose: We performed a comprehensive comparative study of the plan quality between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of prostate cancer. Methods and Materials: Eleven patients with prostate cancer treated at our institution were randomly selected for this study. For each patient, a VMAT plan and a series of IMRT plans using an increasing number of beams (8, 12, 16, 20, and 24 beams) were examined. All plans were generated using our in-house-developed automatic inverse planning (AIP) algorithm. An existing eight-beam clinical IMRT plan, which was used to treat the patient, was used as the reference plan. For each patient, all AIP-generated plans were optimized to achieve the same level of planning target volume (PTV) coverage as the reference plan. Plan quality was evaluated by measuring mean dose to and dose-volume statistics of the organs at risk, especially the rectum, from each type of plan. Results: For the same PTV coverage, the AIP-generated VMAT plans had significantly better plan quality in terms of rectum sparing than the eight-beam clinical and AIP-generated IMRT plans (p < 0.0001). However, the differences between the IMRT and VMAT plans in all the dosimetric indices decreased as the number of beams used in IMRT increased. IMRT plan quality was similar or superior to that of VMAT when the number of beams in IMRT was increased to a certain number, which ranged from 12 to 24 for the set of patients studied. The superior VMAT plan quality resulted in approximately 30% more monitor units than the eight-beam IMRT plans, but the delivery time was still less than 3 min. Conclusions: Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward a Real-Time In Vivo Dosimetry System Using Plastic Scintillation Detectors

Purpose: In the present study, we have presented and validated a plastic scintillation detector (PSD) system designed for real-time multiprobe in vivo measurements. Methods and Materials: The PSDs were built with a dose-sensitive volume of 0.4 mm{sup 3}. The PSDs were assembled into modular detector patches, each containing five closely packed PSDs. Continuous dose readings were performed every 150 ms, with a gap between consecutive readings of <0.3 ms. We first studied the effect of electron multiplication. We then assessed system performance in acrylic and anthropomorphic pelvic phantoms. Results: The PSDs were compatible with clinical rectal balloons and were easily inserted into the anthropomorphic phantom. With an electron multiplication average gain factor of 40, a twofold increase in the signal/noise ratio was observed, making near real-time dosimetry feasible. Under calibration conditions, the PSDs agreed with the ion chamber measurements to 0.08%. Precision, evaluated as a function of the total dose delivered, ranged from 2.3% at 2 cGy to 0.4% at 200 cGy. Conclusion: Real-time PSD measurements are highly accurate and precise. These PSDs can be mounted onto rectal balloons, transforming these clinical devices into in vivo dose detectors without modifying current clinical practice. Real-time monitoring of the dose delivered near the rectum during prostate radiotherapy should help radiation oncologists protect this sensitive normal structure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is a Loose-Seed Nomogram Still Valid for Prostate Brachytherapy in a Stranded-Seed Era?

Purpose: To characterize the amount of activity required to treat the prostate with stranded {sup 125}I radioactive seeds and compare our stranded data with the amount of activity recommended when individual seeds are implanted using a Mick applicator. Methods and Materials: Data from two groups of patients at University of Texas M. D. Anderson Cancer Center who were treated with prostate brachytherapy as monotherapy were analyzed. The first group included 100 patients implanted with individual seeds in 2000 and 2001. The second group comprised 81 patients for whom stranded seeds were implanted in 2006 and 2007. Seeds in both groups were {sup 125}I seeds with an air kerma strength of 0.497 U per seed (0.391 mCi per seed). The prescribed dose to planning target volume was 145 Gy. Results: The total implanted activity and the number of seeds used were significantly lower in the second group (p < 0.0001) than in the first group. The reduction in activity in the stranded-seed group was approximately 23% for a 20-cm{sup 3} prostate and approximately 15% for a 60-cm{sup 3} prostate. With equivalent activity between the two groups, the stranded-seed treatment covered a larger treatment volume with the prescribed dose. Conclusions: The amount of activity required to effectively treat a prostate of a given volume was lower with stranded seeds than with loose seeds. Our experience suggests that prostate brachytherapy that uses stranded seeds leads to a more efficient implant with fewer seeds and lower overall activity, resulting in improved homogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Evaluation of Automatic Anatomy Segmentation Algorithm on Repeat or Four-Dimensional Computed Tomography Images Using Deformable Image Registration Method

Purpose: Auto-propagation of anatomic regions of interest from the planning computed tomography (CT) scan to the daily CT is an essential step in image-guided adaptive radiotherapy. The goal of this study was to quantitatively evaluate the performance of the algorithm in typical clinical applications. Methods and Materials: We had previously adopted an image intensity-based deformable registration algorithm to find the correspondence between two images. In the present study, the regions of interest delineated on the planning CT image were mapped onto daily CT or four-dimensional CT images using the same transformation. Postprocessing methods, such as boundary smoothing and modification, were used to enhance the robustness of the algorithm. Auto-propagated contours for 8 head-and-neck cancer patients with a total of 100 repeat CT scans, 1 prostate patient with 24 repeat CT scans, and 9 lung cancer patients with a total of 90 four-dimensional CT images were evaluated against physician-drawn contours and physician-modified deformed contours using the volume overlap index and mean absolute surface-to-surface distance. Results: The deformed contours were reasonably well matched with the daily anatomy on the repeat CT images. The volume overlap index and mean absolute surface-to-surface distance was 83% and 1.3 mm, respectively, compared with the independently drawn contours. Better agreement (>97% and <0.4 mm) was achieved if the physician was only asked to correct the deformed contours. The algorithm was also robust in the presence of random noise in the image. Conclusion: The deformable algorithm might be an effective method to propagate the planning regions of interest to subsequent CT images of changed anatomy, although a final review by physicians is highly recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗