Search NASA⌕ Search

Engineering topics

Kueck, John D

Publications and source records attributed to Kueck, John D.

Utility-Side Voltage and PQ Control with Inverter-based Photovoltaic Systems

Distributed energy resources (DER) are small generators located close to the load centers. The DERs that are integrated to the grid with the power electronic converter interfaces are capable of providing nonactive power in addition to active power. Hence, they are capable of regulating the voltages of the weak buses in the distribution systems. This paper discusses the voltage control capability of photovoltaic (PV) systems as compared to the traditional capacitor banks. The simulation results prove the effectiveness of dynamic voltage control capability of inverter-based PV. With the proper control algorithm, the active and nonactive power from the DERs like battery banks or solar photovoltaic can be controlled independently. This paper also presents the scenario of controlling the active and nonactive power from the PV array to track and supply the local load.

99 GENERAL AND MISCELLANEOUS↗

Voltage and Current Unbalance Compensation Using a STATCOM

A three-phase insulated gate bipolar transistor (IGBT)-based static var compensator (STATCOM) is used for voltage and/or current unbalance compensation. An instantaneous power theory is adopted for real-time calculation and control. Three control schemes, current control, voltage control, and integrated control are proposed to compensate the unbalance of current, voltage, or both. The compensation results of the different control schemes in unbalance cases (load unbalance or voltage source unbalance) are compared and analyzed. The simulation and experimental results show that the control schemes can compensate the unbalance in load current or in the voltage source. Different compensation objectives can be achieved, i.e., balanced and unity power factor source current, balanced and regulated voltage, or both, by choosing appropriate control schemes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Voltage Control with Distributed Energy Resources: Algorithm, Theoretical Analysis, Simulation and Field Test Verification

Abstract Distributed energy resources (DE) or distributed generators (DG) with power electronics interfaces and logic control using local measurements are capable of providing reactive power related ancillary system services. In particular, local voltage regulation has drawn much attention in regards to power system reliability and voltage stability, especially from past major cascading outages. This paper addresses the challenges of controlling DEs to regulate local voltage in distribution systems. An adaptive voltage control method has been proposed to dynamically modify control parameters to respond to system changes. Theoretical analysis shows that there exists a corresponding formulation of the dynamic control parameters; hence the adaptive control method is theoretically solid. Both simulation and field experiment test results at the Distributed Energy Communications and Controls (DECC) Laboratory confirm that this method is capable of satisfying the fast response requirement for operational use without causing oscillation, inefficiency, or system equipment interference. Since this method has a high tolerance to real-time data shortage and is widely adaptive to variable power system operational situations, it is quite suitable for broad utility application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Properly Understanding the Impacts of Distributed Resources on Distribution Systems

The subject paper discusses important impacts of distributed resources on distribution networks and feeders. These include capacity, line losses, voltage regulation, and central system support (such as volt/var via central generators and substation) as the number, placement and penetration levels of distributed resources are varied. Typically, the impacts of distributed resources on the distribution system are studied by using steady-state rather than dynamic analysis tools. However, the response time and transient impacts of both system equipment (such as substation/feeder capacitors) and distributed resources needs to be taken into account and only dynamic analysis will provide the full impact results. ORNL is wrapping up a study of distributed resources interconnected to a large distribution system considering the above variables. A report of the study and its results will be condensed into a paper for this panel session. The impact of distributed resources will vary as the penetration level reaches the capacity of the distribution feeder/system. The question is how high of a penetration of distributed resource can be accommodated on the distribution feeder/system without any major changes to system operation, design and protection. The impacts most surely will vary depending upon load composition, distribution and level. Also, it is expected that various placement of distributed resources will impact the distribution system differently.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Instantaneous Active and Nonactive Power Control of Distributed Energy Resources with Current Limiter

Abstract -- Distributed energy resources (DER) with a power electronics inverter interface can provide both active power and nonactive power simultaneously and independently. A decoupled control algorithm of active power and nonactive power is developed based on the instantaneous active power and nonactive power theory. A current limiter is combined to the control algorithm, and it ensures that the inverter is not overloaded. During the normal system operation, the active power has higher priority over the nonactive power so that the energy from a DER can be fully transferred to the grid. Within the inverter s capability, nonactive power is provided to the grid as required. With this control algorithm, the inverter s capabilities are taken full advantage at all times, both in terms of functionality as well as making use of its full KVA rating. Through the algorithm, the inverter s active power and nonactive power are controlled directly, simultaneously, and independently. Several experimental results fully demonstrate the validity and effectiveness of this new control algorithm. As evidenced by the fast dynamic response that results, a DER system with the control algorithm can provide full services to the grid in both steady state and during transient events.

30 DIRECT ENERGY CONVERSION↗

Local Voltage Support from Distributed Energy Resources to Prevent Air Conditioner Motor Stalling

Microgrid voltage collapse often happens when there is a high percentage of low inertia air-conditioning (AC) motors in the power systems. The stalling of the AC motors results in Fault Induced Delayed Voltage Recovery (FIDVR). A hybrid load model including typical building loads, AC motor loads, and other induction motor loads is built to simulate the motoring stalling phenomena. Furthermore, distributed energy resources (DE) with local voltage support capability are utilized to boost the local bus voltage during a fault, and prevent the motor stalling. The simulation results are presented. The analysis of the simulation results show that local voltage support from multiple DEs can effectively and economically solve the microgrid voltage collapse problem.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Grid Demos Provide Guidance on Integrating DER and RES into the Distribution System with Consideration of Transmission Impacts, Market Signals, and Technologies

This paper describes the overall process for developing a planning criteria and deployment strategy for technology applications under the US Department of Energy (USDOE) and Electric Power Research Institute (EPRI) Smart Grid programs. These activities described provide an understanding of each demonstration and how they individually and as group further industry knowledge of Distributed Energy Resources (DER) and Renewable Energy Sources (RES) impact the grid and how the distribution grid can interact with DER and RES in smart ways. Both USDOE through its Renewable and Distributed Systems Integration (RDSI) and EPRI via its Smart Grid Demonstration Program both assess how DER and RES can be integrated and operated to lower the carbon footprint.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗