Search NASA⌕ Search

Engineering topics

Kuhne, Wendy

Publications and source records attributed to Kuhne, Wendy.

Applications of LIF to Document Natural Variability of Chlorophyll Content and Cu Uptake in Moss

Chlorophyll has long been used as a natural indicator of plant health and photosynthetic efficiency. Laser-induced fluorescence (LIF) is an emerging technique for understanding broad spectrum organic processes and has more recently been used to monitor chlorophyll response in plants. Previous work has focused on developing a LIF technique for imaging moss mats to identify metal contamination with the current focus shifting toward application to moss fronds and aiding sample collection for chemical analysis. Two laser systems (CoCoBi a Nd:YGa pulsed laser system and Chl-SL with two blue continuous semiconductor diodes) were used to collect images of moss fronds exposed to increasing levels of Cu (1, 10, and 100 nmol/cm 2 ) using a CMOS camera. The best methods for the preprocessing of images were conducted before the analysis of fluorescence signatures were compared to a control. The Chl-SL system performed better than the CoCoBi, with dynamic time warping (DTW) proving the most effective for image analysis. Manual thresholding to remove lower decimal code values improved the data distributions and proved whether using one or two fronds in an image was more advantageous. A higher DTW difference from the control correlated to lower chlorophyll a/b ratios and a higher metal content, indicating that LIF, with the aid of image processing, can be an effective technique for identifying Cu contamination shortly after an event.

59 BASIC BIOLOGICAL SCIENCES↗

Laser-Induced Fluorescence for Monitoring Environmental Contamination and Stress in the Moss Thuidium plicatile

The ability to detect, measure, and locate the source of contaminants, especially heavy metals and radionuclides, is of ongoing interest. A common tool for contaminant identification and bioremediation is vegetation that can accumulate and indicate recent and historic pollution. However, large-scale sampling can be costly and labor-intensive. Hence, non-invasive in-situ techniques such as laser-induced fluorescence (LIF) are becoming useful and effective ways to observe the health of plants through the excitation of organic molecules, e.g., chlorophyll. The technique presented utilizes images collected of LIF in moss to identify different metals and environmental stressors. Analysis through image processing of LIF response was key to identifying Cu, Zn, Pb, and a mixture of the metals at nmol/cm 2 levels. Specifically, the RGB values from each image were used to create density histograms of each color channel’s relative pixel abundance at each decimal code value. These histograms were then used to compare color shifts linked to the successful identification of contaminated moss samples. Photoperiod and extraneous environmental stressors had minimal impact on the histogram color shift compared to metals and presented with a response that differentiated them from metal contamination.

59 BASIC BIOLOGICAL SCIENCES↗

Molecular and Microstructural Bases for Understanding Microplastic Origin, Transport, and Fate

The formation of micro and nanoplastics from parent plastics is one of the most challenging ecological threats since plastic pollution reaches even the most desolate places on earth and is expected to double by 2030. The goal of this project is to understand physico-chemical properties on microplastics formation, transport, and fate by analyzing the microplastics found in environmentally collected samples at SRS, supported by lab-based experiments. An initial assessment found and identified microplastics and micronizing plastics in Fourmile Branch and the Savannah River. Fourmile Branch also carried trace-level radioactive contaminants associated with the Site’s legacy missions, which may incorporate into entrained microplastics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of FRET clusters for CBRN Detection

Advanced sensor capabilities for the simultaneous on-site detection of specific chemical, biological, and radiological/nuclear (CBRN) threats is important to significantly limit the risk of exposure to personnel and allow the rapid collection of essential scientific data and critical evidence. Commercially available sensor capabilities are generally complex, and/or require highly specific and ultra-sensitive methods that are often power demanding or require offsite post-analysis for positive detection, leaving personnel vulnerable. The goal of this project is to develop a portable sensor capable of simultaneously detecting CBRN signatures using a multiplexed Förster Resonance Energy Transfer (FRET) based sensor. FRET sensors are tailorable, specific, and highly dependent on the donor-acceptor distance. In this project, nanoparticles were functionalized with aptamers that were designed for the detection of methylphosphonate, a sarin metabolite. FRET was measured between quantum dot donors and dye and metal nanoparticle acceptors using optical spectroscopy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics

The ability to rapidly detect and characterize the chemistry of trace quantities of inorganic species has multiple potential applications, including nuclear safeguards, nuclear forensics, and environmental monitoring. Some mass spectrometric methods currently exist, but they are costly and time-intensive, often destroying chemical information in the process of ionization. Ambient mass spectrometry is a relatively new analytical method in which samples are introduced to the mass spectrometer from atmospheric pressure, rather than from high vacuum. Ambient MS can operate with gentler ionization methods such as electrospray ionization (ESI) and paper-spray ionization (PSI), reducing fragmentation and preserving the chemical information of the analyte. This may be useful for determining the intended purpose of material in a sample. Strontium, part of nuclear fallout, is analyzed here to test these new analytical methods for viability. Electrospray ionization mass spectrometry functions by spraying the sample as a solution through a needle charged to a few kV. A nebulizing gas flows out along with the sample to create the spray before droplets enter a drying chamber with heated drying gas to remove the solvent molecules. From there bare analyte ions enter the mass spectrometer. This method has the advantage of relatively fast sample preparation and stable ionization. More stable ionization produces higher-quality data. Paper-spray ionization mass spectrometry operates by applying sample to a paper triangle. The paper triangle is then electrified in a metal clamp to a few kV before spray solvent is applied. The spray solvent transports analyte in the sample to the tip, where it is ionized and enters the mass spectrometer. One advantage of this method is reduced sample preparation - an analyst can even swipe a surface and cut a triangle directly from the swipe. The data analysis serves to rapidly process tens of samples all at once. The mass spectrometer outputs a file containing a few hundred spectra for each sample. The pipeline processes each one to identify peaks of interest. A full palette of data analysis metrics are generated, including plots of the raw data and plots of calculated values such as isotopic ratios. The pipeline filters the raw data to remove noise and background peaks, as well as peaks representing detector saturation. A heat map is generated to show the overall spectrum in mass-time- intensity space. Post-processing, we obtained the desired calibration curves, demonstrating that both ESI-MS and PSI-MS are viable methods for quantifying trace amounts of inorganics while retaining their chemical speciation information. ESI-MS demonstrated a linear response region of 100 ppb to 20 ppm, with a limit-of-detection of around 100 ppb. At top left is an example spectrum with the {sup 88}SrNO{sub 3} peak identified to show the retention of chemical speciation. PSI-MS showed a linear response region of around 1 ppb to 1 ppm, with a limit-of-detection of near 1 ppb. PSI-MS produced more erratic results than ESI-MS, likely due to the variability in ionization resulting from manual positioning of the paper triangle near the MS inlet. Future efforts will focus on improving the repeatability of PSI-MS as well as analyzing other species of interest such as cerium and uranium. Improvements will also be made to create more reliable data extraction and intelligent data filtering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integration of ecosystem science into radioecology: A consensus perspective

In the Fall of 2016 a workshop was held which brought together over 50 scientists from the ecological and radiological fields to discuss feasibility and challenges of reintegrating ecosystem science into radioecology. There is a growing desire to incorporate attributes of ecosystem science into radiological risk assessment and radioecological research more generally, fueled by recent advances in quantification of emergent ecosystem attributes and the desire to accurately reflect impacts of radiological stressors upon ecosystem function. This work is a synthesis of the discussions and consensus of the workshop participant's responses to three primary questions, which were: 1) How can ecosystem science support radiological risk assessment? 2) What ecosystem level endpoints potentially could be used for radiological risk assessment? and 3) What inference strategies and associated methods would be most appropriate to assess the effects of radionuclides on ecosystem structure and function? The consensus of the participants was that ecosystem science can and should support radiological risk assessment through the incorporation of quantitative metrics that reflect ecosystem functions which are sensitive to radiological contaminants. The participants also agreed that many such endpoints exit or are thought to exit and while many are used in ecological risk assessment currently, additional data need to be collected that link the causal mechanisms of radiological exposure to these endpoints. Finally, the participants agreed that radiological risk assessments must be designed and informed by rigorous statistical frameworks capable of revealing the causal inference tying radiological exposure to the endpoints selected for measurement.

54 ENVIRONMENTAL SCIENCES↗