Search NASA⌕ Search

Engineering topics

Kumar, R

Publications and source records attributed to Kumar, R.

At least 19 records

SU-G-TeP3-05: In Vitro Demonstration of Endothelial Dose Enhancement Due to Gold Nanoparticles During Low-Voltage Radiotherapy

Purpose: Oraya Therapy uses low-voltage, stereotactic, highly targeted X-rays for the treatment of wet age-related macular degeneration (AMD) — offering a new option for patients worldwide. Neovascular endothelial cells play a crucial role in the pathogenesis of this disease. This in-vitro study investigates the potential of gold nanoparticles (GNP) to enhance endothelial cell damage during low-voltage radiotherapy towards potential applications in the treatment of wet-AMD. Methods: Primary human umbilical cord vein endothelium cells (HUVEC) were treated with 1.4 nm sized GNPs for 24 hrs and then irradiated with variable X-ray doses using an Oraya therapy system (100 kVp) or a Small Animal Radiation and Research platform (SARRP) at other beam qualities (up to 220 kVp). Radio-sensitization was assessed by clonogenic assays. Variable concentrations of GNPs (0.05 mg/ml, 0.1 mg/ml, 0.25 mg/ml, 0.5 mg/ml, and 1 mg/ml) where employed. The dose enhancement factor (DEF) was calculated as the ratio of radiation doses required to give the same biological effect (survival factor, SF) with and without GNPs. Results: Preliminary results show DEFs of up to 2.62 for the different combinations of x-ray doses and GNP concentrations and beam qualities. In general the DEF increased with increase in GNP concentration. However, for high doses the effect of GNP becomes less apparent likely due to already high cell kill by the radiation alone. Conclusion: The findings suggest that targeted GNPs can play a significant synergistic role in enhancing stereotactic radiosurgery for wet AMD. The results also provide impetus for ongoing studies to find the optimal synergy between the doses or beam energies and GNPs concentration. This will benefit in-vivo studies towards development of nanoparticle-aided radiotherapy for treatment of wet-AMD and potentially ocular cancers.

60 APPLIED LIFE SCIENCES↗

WE-FG-BRA-02: Docetaxel Eluting Brachytherapy Spacers for Local Chemo-Radiation Therapy in Prostate Cancer

Purpose: We propose an innovative combinatorial treatment strategy of Local ChemoRadiation Therapy (LCRT) using a sustained drug delivery platform in the form of a spacer to locally radio-sensitize the prostate with Docetaxel (DTX) enabling a synergistic cure with the use of lower radiation doses. These biodegradable spacers are physically similar to the inert spacers routinely used in prostate brachytherapy but are now loaded with formulations of DTX. Methods: Spacers were loaded with ∼500µg Docetaxel (DTX) for prostate cancer studies. The implants were characterized in vitro using SEM and HPLC. The release kinetic studies were carried out in buffer (pH 6.0) at 37°C. Subcutaneous PC3 tumors were xenografted in nude mice. Prostate cancer studies were done with and without radiation using SARRP at 5Gy, 10Gy, and 15Gy. Drug-loaded implants were injected once intratumorally using an 18G brachytherapy needle. Results: The release study in vitro showed a highly sustained release for multiple weeks at therapeutically relevant doses. The monotherapy with local DTX spacer showed sustained tumor inhibition compared to empty implants and an equivalent DTX dose given systemically. At 40 days, 89% survival was observed for mice treated with DTX implants compared with 0% in all other treatment groups. The combined treatment with local DTX spacer and radiation (10Gy) showed the highest degree of tumor suppression (significant tumor growth inhibition by day 90). The control mice showed continuous tumor growth and were scarified by day 56. Groups of mice treated with DTX-spacer or radiation alone showed initial tumor suppression but growth continued after day 60. A larger experiment is ongoing. Conclusion: This approach provides localized delivery of the chemotherapeutic sensitizer directly to the tumor and avoids the toxicities associated with both brachytherapy and current systemic delivery of docetaxel. Sustained release of DTX is an effective chemotherapy option alone or in combination with radiation therapy.

60 APPLIED LIFE SCIENCES↗

First observation of the decay B 0 → ψ ( 2 S ) π 0

We report a measurement of the B 0 → ψ(2S)π 0 branching fraction based on the full Υ(4S) data set of 772 × 10 6 BB¯ pairs collected by the Belle detector at the KEKB asymmetric-energy e + e – collider. We obtain B(B 0 → ψ(2S)π 0 ) = (1.17 ± 0.17(stat) ± 0.08(syst)) × 10 –5 . Here, the result has a significance of 7.2 standard deviations and is the first observation of the decay B 0 → ψ(2S)π 0 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-11: Measurement of Eye Lens Dose for Varian On-Board Imaging with Different CBCT Acquisition Techniques

Purpose: To measure actual patient eye lens dose for different cone beam computed tomography (CBCT) acquisition protocol of Varian’s On Board Imagining (OBI) system using Optically Stimulated Luminescence (OSL) dosimeter and study the eye lens dose with patient geometry and distance of isocenter to the eye lens Methods: OSL dosimeter was used to measure eye lens dose of patient. OSL dosimeter was placed on patient forehead center during CBCT image acquisition to measure eye lens dose. For three different cone beam acquisition protocol (standard dose head, low dose head and high quality head) of Varian On-Board Imaging, eye lens doses were measured. Measured doses were correlated with patient geometry and distance between isocenter to eye lens. Results: Measured eye lens dose for standard dose head was in the range of 1.8 mGy to 3.2 mGy, for high quality head protocol dose was in range of 4.5mGy to 9.9 mGy whereas for low dose head was in the range of 0.3mGy to 0.7mGy. Dose to eye lens is depends upon position of isocenter. For posterioraly located tumor eye lens dose is less. Conclusion: From measured doses it can be concluded that by proper selection of imagining protocol and frequency of imaging, it is possible to restrict the eye lens dose below the new limit set by ICRP. However, undoubted advantages of imaging system should be counter balanced by careful consideration of imaging protocol especially for very intense imaging sequences for Adoptive Radiotherapy or IMRT.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-05: Next Generation Radiotherapy Biomaterials Loaded With Gold Nanoparticles

Purpose: It has been proposed that routinely used inert radiotherapy (RT) biomaterials (e.g. fiducials, spacers) can be upgraded to smarter ones by coating/loading them with radiosensitizing gold nanoparticles (GNPs), for sustained in-situ release after implantation to enhance RT. In this work, we developed prototypes of such RT biomaterials and investigated the sustained release of GNPs from the biomaterials as a function of design parameters. Methods: Prototype smart biomaterials were produced by incorporating the GNPs in poly(D,L-lactide-co-glycolide) (PLGA) polymer millirods during the gel phase of production. For comparison, commercially available spacers were also coated with a polymer film loaded with fluorescent GNP. Optical/spectroscopy methods were used to monitor in vitro release of GNPs over time as a function of different design parameters: polymer weighting, type, and initial (loading) GNP concentrations. Inductively coupled plasma mass spectrometry was employed to verify GNP release. Results: Results showed that gold nanoparticles could be successfully loaded in the new RT biomaterial prototypes. Burst release of GNPs could be achieved within 1 to 25 days depending on the preparation approach. Burst release was followed by sustained release profile over time. The amount of released GNP increased with increasing loading concentration as expected. The release profiles could also be customized as a function of polymer weighting, or preparation approaches. Conclusion: Considered together, our results highlight potential for the development of next generation RT biomaterials loaded with GNPs customizable to different RT schedules. Such biomaterials could be employed as needed instead of currently used inert spacers/fiducials at no additional inconvenience to patients, to enhance RT.

60 APPLIED LIFE SCIENCES↗

Observation of X ( 3872 ) in B → X ( 3872 ) K π decays

We report the first observation of B 0 →X(3872)(K + π – ) and evidence for B + → X(3872)(K 0 π + ). We measure the product of branching fractions for the former to be B(B 0 → X(3872)(K + π – )) × B(X(3872) → J/ψπ + π – ) = (7.9 ± 1.3(stat) ± 0.4(syst)) × 10 –6 and find that B 0 → X(3872)K*(892) 0 does not dominate the B 0 → X(3872)K + π – decay mode. We also measure B(B + → X(3872)(K 0 π + )) × B(X(3872) → J/ψπ + π – ) = (10.6 ± 3.0(stat) ± 0.9(syst)) × 10 –6 . Furthermore, this study is based on the full data sample of 711 fb –1 (772 × 10 6 BB¯ pairs) collected at the Υ(4S) resonance with the Belle detector at the KEKB collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

WE-G-BRE-08: Radiosensitization by Olaparib Eluting Nanospheres

Purpose: Permanent prostate brachytherapy often uses inert bio-absorbable spacers to achieve the desired geometric distribution of sources within the prostate. Transforming these spacers into implantable nanoplatforms for chemo-radiation therapy (INCeRT) provides a means of providing sustained in-situ release of radiosensitizers in the prostate to enhance the therapeutic ratio of the procedure. Olaparib, a PARP inhibitor, suppresses DNA repair processes present during low dose rate continuous irradiation. This work investigates the radiosensitizing/DNA damage repair inhibition by NanoOlaparib eluting nanospheres. Methods: Human cell line PC3 (from ATCC), was maintained in F12-k medium supplemented with fetal bovine serum. Clonogenic assay kit (from Fischer Scientific) was used to fix and stain the cells to determine the long term effects of irradiation. Nanoparticle size and zeta potential of nanospheres were determined using a Zeta particle size analyzer. The incorporation of Olaparib in nanospheres was evaluated by HPLC. Irradiation was performed in a small animal irradiator operating at 220 KeV.The long term effects of radio-sensitization with olaparib and nanoolaparib was determined using the clonogenic assay at 2 Gy and 4 Gy doses. The cells were allowed to grow for around 10 doubling cycles, The colonies were fixed and stained using clonogenic assay kit. The excess stain was washed off using DI water and the images were taken using a digital camera. Results: Radiosensitization studies were carried out in prostate cancer cell line, PC3 radiation at 0, 2 and 4Gy doses. Strongest dose response was observed with nanoolaparib treated cells compared to untreated cells. Conclusion: A two stage drug release of drug eluting nanospheres from a biodegradable spacer has been suggested for sustained in-situ release of Olaparib to suppress DNA repair processes during prostate brachytherapy. The Olaparib eluting nanospheres had the same in-vitro radiosensitizing effect as free olaparib. DOD 1R21CA16977501, A. David Mazzone Awards Program 2012PD164.

60 APPLIED LIFE SCIENCES↗

Check for chirality in {sup 102}Rh

Excited states in {sup 102}Rh, populated by the fusion-evaporation reaction {sup 94}Zr({sup 11}B,3n){sup 102}Rh at a beam energy of 36 MeV, were studied using the INGA spectrometer at IUAC, New Delhi. The angular correlations and the electromagnetic character of some of the gamma-ray transitions observed were investigated in details. A new chiral candidate sister band was found in the level-scheme of {sup 102}Rh. Lifetimes of exited states in {sup 102}Rh were measured by means of the Doppler-shift attenuation technique. The experimental results do not support the presence of static chirality in {sup 102}Rh.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of buffer layer growth temperature on epitaxial GaN films deposited by magnetron sputtering

Epitaxial GaN films were deposited by reactive sputtering of a GaAs target in 100 % nitrogen at 700 deg. C on ZnO buffer layers grown at different substrate temperatures over sapphire substrates. High resolution X-ray diffraction measurements and the corresponding analysis show that the growth temperature of buffer layers significantly affects the micro-structural parameters of GaN epilayer, such as lateral coherence length, tilt and twist, while the vertical coherence length remains unaffected. The optimum substrate temperature for buffer layer growth has been found to be 300 deg. C. High epitaxial quality GaN film grown on such a buffer layer exhibited micro strain of 1.8x10{sup -4} along with screw and edge type dislocation densities of 7.87x10{sup 9} and 1.16x10{sup 11}, respectively.

36 MATERIALS SCIENCE↗

Effect of substrate temperature on microstructure of epitaxial ZnO films grown on sapphire by sputtering

The microstructure of epitaxial ZnO films on (0001) sapphire substrates deposited by reactive sputtering in substrate temperature (T{sub s}) range of 100 - 500 deg. C were investigated by High-resolution X-ray diffraction. The studies show the presence of a strained 2D layer along with 3D crystallites at low T{sub s}, whereas 3D growth is dominant at higher T{sub s}, resulting in formation of mosaic structure with lesser point and line defects.

36 MATERIALS SCIENCE↗

Identification of fission-like events in the {sup 16}O + {sup 181}Ta system: Mass and isotopic yield distribution

In this paper, nuclear reaction cross sections for 24 fission-like fragments (30{<=}Z{<=}60) have been measured for the 6.5 MeV/A {sup 16}O + {sup 181}Ta system. The recoil-catcher activation technique was employed followed by off-line {gamma} spectroscopy. The isotopic yield distributions for yttrium and indium isotopes have been obtained from the experimental data. The variance of the presently measured isotopic yield distributions have been found to be in agreement with the literature values. However, the variance of the mass distribution of fission residues has found to be narrower as compared to other relatively heavier systems. A self-consistent approach to determining the isobaric charge dispersion parameters has been adopted. The measured fission cross sections at 97 and 100 MeV are satisfactorily described by a statistical model code. An attempt has been made to explain the production cross sections of intermediate mass residues in the fission of heavy residues populated via complete and/or incomplete fusion processes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Excited states in {sup 99}Pd

Excited states in the {sup 99}Pd nucleus populated in the {sup 75}As({sup 28}Si, p3n) fusion-evaporation reaction at E{sub lab}=120 MeV have been investigated through in-beam {gamma}-ray spectroscopic techniques using an array of Compton-suppressed clover detectors. The level scheme is established up to excitation energy {approx}11.5 MeV and spin {approx}25({h_bar}/2{pi}) with the addition of about 60 new transitions. The level structures observed in {sup 99}Pd have been interpreted in the framework of a microscopic theory based on the deformed Hartree-Fock and angular momentum projection techniques. Band structures at lower spins are based on the low-{Omega} {nu}g{sub 7/2} and {nu}d{sub 5/2} orbitals, and those at higher spins are reproduced for the {pi}(g{sub 9/2}){sup 5} x {pi}(g{sub 7/2}) x {nu}(g{sub 7/2}){sup 2} x {nu}(h{sub 11/2}){sup 2} x {nu}(g{sub 9/2}){sup -1} and {pi}(g{sub 9/2}){sup 6} x {nu}(g{sub 9/2}){sup 10} x {nu}(g{sub 7/2}){sup 2} x {nu}(h{sub 11/2}) configurations. The octupole correlations in {sup 99}Pd have been inferred from new interband E1 transitions linking the {Delta}I=1 states of the bands based on the {nu}h{sub 11/2} and {nu}d{sub 5/2} orbitals ({Delta}l=3, {Delta}j=3, and {Delta}{pi}=-1) with the deduced B(E1) values {approx}10{sup -6} W.u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Breakup threshold anomaly in the near-barrier elastic scattering of {sup 6}Li+{sup 116,112}Sn

We have measured the elastic scattering of the weakly bound {sup 6}Li on the {sup 116,112}Sn targets, at energies close to the Coulomb barrier. The energy dependence of the interaction potential has been investigated by two different methods and the presence of the breakup threshold anomaly is observed. We have also derived the total reaction cross sections for the above systems and compared them to those of other systems with halo, weakly bound, and tightly bound projectiles on targets with similar masses. The reaction cross sections are largest for systems with halo nuclei, then the systems with no-halo weakly bound nuclei, and the smallest cross sections are those for tightly bound systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Band Structure of {sup 85}Sr

High spin states in {sup 85}Sr were populated using the reaction {sup 76}Ge({sup 13}C, 4n) at a beam energy of 52 MeV. Gamma-gamma coincidence measurements along with investigation of directional correlation ratios were utilized to establish the extended level scheme upto I{sup {pi}}= (35/2{sup -}). One of the positive parity states observed at 3383.3 keV ((I{sup {pi}}= 19/2{sup (+)}) may be considered as a magnetic rotational ({Delta}I = 1) band, the negative parity states built on 3028.0 level show an irregular behaviour and does not exhibit magnetic rotation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Decoupling behavior in {sup 132}La

Heavy-ion fusion reactions {sup 122}Sn({sup 14,15}N, xn){sup 132}La have been utilized for the lifetime measurements using the recoil distance method. The lifetimes of seven low-lying excited states were obtained. In addition, the lifetimes of two states belonging to a band, which was identified as a decoupled band, were obtained. The decoupling behavior in {sup 132}La has been theoretically investigated using the particle-rotor model in the model space of {pi}h{sub 11/2} and ({nu}s{sub 1/2}, {nu}d{sub 3/2}). The pseudospin coupling model was also utilized to understand the decoupling behavior in terms of the valence-particle configuration {pi}h{sub 11/2}({Omega}{sub {pi}}=(1/2)) x {nu}[411-tilde]({Omega}{sub {nu}}=(1/2),(3/2)), and a reasonable agreement with the experiment was obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and adaptation of a novel supercritical extraction facility for operation in a glove box for recovery of radioactive elements

The design and development of a novel supercritical extraction experimental facility adapted for safe operation in a glove box for the recovery of radioactive elements from waste is described. The apparatus incorporates a high pressure extraction vessel, reciprocating pumps for delivering supercritical fluid and reagent, a back pressure regulator, and a collection chamber. All these components of the system have been specially designed for glove box adaptation and made modular to facilitate their replacement. Confinement of these materials must be ensured in a glove box to protect the operator and prevent contamination to the work area. Since handling of radioactive materials under high pressure (30 MPa) and temperature (up to 333 K) is involved in this process, the apparatus needs elaborate safety features in the design of the equipment, as well as modification of a standard glove box to accommodate the system. As a special safety feature to contain accidental leakage of carbon dioxide from the extraction vessel, a safety vessel has been specially designed and placed inside the glove box. The extraction vessel was enclosed in the safety vessel. The safety vessel was also incorporated with pressure sensing and controlling device.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗