Search NASA⌕ Search

Engineering topics

Kumar, S

Publications and source records attributed to Kumar, S.

At least 19 records

SU-F-P-50: Performance Evaluation of Optically Stimulated Luminescence (OSL) NanoDots in Therapy and Imaging In-Vivo Dose Measurement During Patient Treatment

Purpose: This study was designed to evaluate the performance of optically stimulated Luminescence (OSL) nanoDots as in-vivo dosimeter. For the measurements of surface doses as well as scattered plus leakage doses, nanoDots were used during the setup verification as well as during the treatment delivery. Methods: For a total seven patients undergoing radiotherapy by volumetric modulated arc therapy, surface doses from image guidance and scattered plus leakage doses from treatment delivery were measured. Two sets of calibration curves were generated – one for therapy and another for imaging. Two different nanoDots were used for imaging and therapy doses. Imaging nanoDots were placed at the isocenter only at the time of CBCT and therapy nanoDots were placed at 25 cm away from the isocenter (either in cranial or in caudal direction) only at the time of treatment delivery. During the entire course, nanoDots were placed at the same measurement points. NanoDots were read after 15 minutes of their exposure. For the next fraction, nanoDots were corrected for the residual doses from the previous fractions. Results: Measured surface doses during imaging were 0.14±0.32 cGy, 0.11±0.04 cGy, 0.12±0.53 cGy, 0.04±0.02 cGy, 0.13±0.23 cGy, 0.11±0.43 cGy, 0.10±0.04 cGy with overall mean dose of 0.08±0.1 cGy. Measured doses during treatment delivery, indicative of scattered and leakage dose, were 0.84±0.43 cGy, 1.3±0.4 cGy, 1.4±0.4 cGy, 0.18±0.48 cGy, 0.78±0.29 cGy, 0.27±0.08 cGy, 0.78±0.07 cGy with overall mean dose of 0.61±1.3 cGy. Conclusion: This dosimeter can be used as supplementary unit to verify the doses. No change in the prescription is recommended based on nanoDots measurement. This study is on-going therefore we are presenting only mere number of patients. A large volume data will be presented after completion of the study with proper statistical analysis.

60 APPLIED LIFE SCIENCES↗

SU-F-T-327: Total Body Irradiation In-Vivo Dose Measurements Using Optically Stimulated Luminescence (OSL) NanoDots and Farmer Type Ion Chamber

Purpose: This study was performed to analyze the agreement between optically stimulated luminescence (OSL) nanoDots measured doses and 0.6 cc Farmer type ionization chamber measured doses during total body irradiation (TBI). Methods: In-vivo dose measurements using OSL nanoDots and Farmer chamber were done in a total of twelve patients who received TBI at our center by bilateral parallel-opposed beams technique. In this technique, the patient is kept inside the TBI box which is filled with rice bags and irradiated using two bilateral parallel opposed beams of 40×40 cm{sup 2} size with 45° collimator rotation at an SSD of 333.5 cm in an Elekta Synergy linear accelerator. All patients received a dose of 2 Gy in single fraction as conditioning regimen. The beams were equally weighted at the midplane of the box. The nanoDots were placed over forehead, right and left neck, right and left lung, umbilicus, right and left abdomen, medial part of thigh, knee and toe. A 0.6 cc Farmer chamber was placed in between the thighs of the patient. Measured doses are reported along with the statistical comparisons using paired sample t-test. Results: For the above sites the mean doses were 212.2±21.1, 218.2±7.6, 218.7±9.3, 215.6±9.5, 217.5±11.5, 214.5±7.7, 218.3±6.8, 221.5±15, 229.1±11.0, 220.5±7.7 and 223.3±5.1 cGy respectively. For all OSL measurements the mean dose was 218.6±11.8 cGy. Farmer chamber measurements yielded a mean dose of 208.8±15.6 cGy. Statistical analysis revealed that there was no significant difference between OSL measured doses in forehead, right and left neck, right and left lung, umbilicus, right and left abdomen and toe and Farmer chamber measured doses (0.72≤p≤0.06). However the mean OSL doses at thigh and knee were statistically different (p<0.05) from the Farmer chamber measurements. Conclusion: OSL measurements were found to be in agreement with Farmer type ionization chamber measurements in in-vivo dosimetry of TBI.

60 APPLIED LIFE SCIENCES↗

SU-F-T-422: Detection of Optimal Tangential Partial Arc Span for VMAT Planning in IntactLeft-Breast Treatment

Purpose: This study was designed to investigate an appropriate arc span for intact partial Left breast irradiation by VMAT planning. Methods: Four cases of carcinoma left intact breast was chosen randomly for this study. Both medial tangential and left-lateral tangential arc (G20°, G25°, G30°, G35°, G40°) were used having the same length and bilaterally symmetric. For each patient base plan was generated for 30° arc and rest of other arc plans were generated by keeping all plan parameters same, only arc span were changed. All patient plans were generated on treatment planning system Monaco (V 5.00.02) for 50 Gy dose in 25 fractions. PTV contours were clipped 3 mm from skin (patient). All plans were normalized in such a way that 95 % of prescription dose would cover 96 % of PTV volume. Results: Mean MU for 20°, 25°, 30°, 35° and 40° were 509 ± 18.8, 529.1 ± 20.2, 544.4 ± 20.8, 579.1 ±51.8, 607.2 ± 40.2 similarly mean hot spot (volume covered by 105% of prescription dose) were 2.9 ± 1.2, 3.7 ± 3.0, 1.5 ± 1.7, 1.3±0.6, 0.4 ± 0.4, mean contralateral breast dose (cGy) were 180.4 ± 242.3, 71.5 ± 52.7, 76.2 ± 58.8, 85.9 ± 70.5, 90.7 ± 70.1, mean heart dose (cGy) were 285.8 ± 87.2, 221.2 ± 62.8, 274.5 ± 95.5, 234.8 ± 73.8, 263.2 ± 81.6, V20 for ipsilateral lung were 15.4 ± 5.3, 14.3 ± 3.6, 15.3 ± 2.9, 14.2 ± 3.9, 14.7 ± 3.2 and V5 for ipsilateral lung were 33.9 ± 8.2, 31.0 ± 3.5, 42.6 ±15.6, 36.4 ± 12.9, 37.0 ± 7.5. Conclusion: The study concluded that appropriate arc span used for tangential intact breast treatment was optimally 30° because larger arc span were giving lower isodose spill in ipsilateral lung and smaller arc were giving heterogeneous dose distribution in PTV.

60 APPLIED LIFE SCIENCES↗

Stoichiometric control of DNA-grafted colloid self-assembly

Significance Recently, there has been an increased interest in understanding the self-assembly of DNA-grafted colloids into different morphologies. Conventional approaches assume that the critical design parameters are the size and number of DNA grafts on each particle. Stoichiometry is viewed as a secondary variable and its exact role in this context is unresolved. In contrast with these expectations, our experiments show that the equilibrium lattice structure can be tuned through variations in the imposed stoichiometry. These findings are captured through simple extensions of the complementary contact model. Stoichiometry is thus shown to be a powerful handle to control these self-assembled structures.

36 MATERIALS SCIENCE↗

Self-assembly, condensation, and order in aqueous lyotropic chromonic liquid crystals crowded with additives

Dense multicomponent systems with macromolecules and small solutes attract a broad research interest as they mimic the molecularly crowded cellular interiors. The additives can condense and align the macromolecules, but they do not change the degree of covalent polymerization. We chose a lyotropic chromonic liquid crystal with reversibly and non-covalently assembled aggregates as a much softer system, reminiscent of 'living polymers', to demonstrate that small neutral and charged additives cause condensation of aggregates with ensuing orientational and positional ordering and nontrivial morphologies of phase separation, such as tactoids and toroids of the nematic and hexagonal columnar phase coexisting with the isotropic melt. Scanning transmission X-ray microscopy (STXM) with near edge X-ray absorption fine structure (NEXAFS) analysis as well as fluorescent microscopy demonstrates segregation of the components. The observations suggest that self-assembly of chromonic aggregates in the presence of additives is controlled by both entropy effects and by specific molecular interactions and provide a new route to the regulated reversible assembly of soft materials formed by low-molecular weight components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct Electron Heating Observed by Fast Waves in ICRF Range on a Low-Density Low Temperature Tokamak ADITYA

Fast wave electron heating experiments are carried out on Aditya tokamak [R = 0.75 m, a = 0.25m,Bt = 0.75T,ne{approx}1-3E13/cc,Te{approx}250eV] with the help of indigenously developed 200 kW, 20-40 MHz RF heating system. Significant direct electron heating is observed by fast waves in hydrogen plasma with prompt rise in electron temperature with application of RF power and it increases linearly with RF power. A corresponding increase in plasma beta and hence increase in stored diamagnetic energy is also observed in presence of RF. We observe an improvement of energy confinement time from 2-4msec during ohmic heating phase to 3-6msec in RF heating phase. This improvement is within the ohmic confinement regime for the present experiments. The impurity radiation and electron density do not escalate significantly with RF power. The direct electron heating by fast wave in Aditya is also predicted by ion cyclotron resonance heating code TORIC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interacting double dark resonances in a hot atomic vapor of helium

We experimentally and theoretically study two different tripod configurations using metastable helium ({sup 4}He*), with the probe field polarization perpendicular and parallel to the quantization axis, defined by an applied weak magnetic field. In the first case, the two dark resonances interact incoherently and merge together into a single electromagnetically induced transparency peak with increasing coupling power. In the second case, we observe destructive interference between the two dark resonances inducing an extra absorption peak at the line center.

74 ATOMIC AND MOLECULAR PHYSICS↗

Effect of In Additive in the Density of Defect States in a-Se{sub 85}Te{sub 15} and a-Se{sub 75}Te{sub 25} Thin Films

In this paper we report the effect of In incorporation in the density of defect states of two binary Se-Te glassy systems. For this purpose, we have chosen here two well known and well studied a-Se{sub 85}Te{sub 15} and a-Se{sub 75}Te{sub 25} glassy alloys. The d. c. conductivity measurements at high electric fields in vacuum evaporated amorphous thin films of Se{sub 85}Te{sub 15}, Se{sub 75}Te{sub 15}In{sub 10} and Se{sub 75}Te{sub 25}, glassy alloys have been made. Current-Voltage (I-V) Characteristics have been measured at various fixed temperatures. In these samples, at low electric fields, ohmic behavior is observed. However, at high electric fields (E{approx}10{sup 4} V/cm), non-ohmic behavior is observed. An analysis of the experimental data confirms the presence of space charge limited conduction (SCLC) in the glassy materials studied in the present case. From the fitting of the data to the theory of SCLC, the density of defect states (DOS) near Fermi level is calculated. The peculiar role of third element In as an impurity in the pure binary Se{sub 75}Te{sub 25} and Se{sub 85}Te{sub 15} glassy alloys is also discussed in terms of electronegativity difference.

36 MATERIALS SCIENCE↗

Magnetic control of breakdown: Toward energy-efficient hollow-cathode magnetron discharges

Characteristics of electrical breakdown of a planar magnetron enhanced with an electromagnet and a hollow-cathode structure, are studied experimentally and numerically. At lower pressures the breakdown voltage shows a dependence on the applied magnetic field, and the voltage necessary to achieve the self-sustained discharge regime can be significantly reduced. At higher pressures, the dependence is less sensitive to the magnetic field magnitude and shows a tendency of increased breakdown voltage at the stronger magnetic fields. A model of the magnetron discharge breakdown is developed with the background gas pressure and the magnetic field used as parameters. The model describes the motion of electrons, which gain energy by passing the electric field across the magnetic field and undergo collisions with neutrals, thus generating new bulk electrons. The electrons are in turn accelerated in the electric field and effectively ionize a sufficient amount of neutrals to enable the discharge self-sustainment regime. The model is based on the assumption about the combined classical and near-wall mechanisms of electron conductivity across the magnetic field, and is consistent with the experimental results. The obtained results represent a significant advance toward energy-efficient multipurpose magnetron discharges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Interaction of single-walled carbon nanotubes with poly(propyl ether imine) dendrimers

We study the complexation of nontoxic, native poly(propyl ether imine) dendrimers with single-walled carbon nanotubes (SWNTs). The interaction was monitored by measuring the quenching of inherent fluorescence of the dendrimer. The dendrimer-nanotube binding also resulted in the increased electrical resistance of the hole doped SWNT, due to charge-transfer interaction between dendrimer and nanotube. This charge-transfer interaction was further corroborated by observing a shift in frequency of the tangential Raman modes of SWNT. We also report the effect of acidic and neutral pH conditions on the binding affinities. Experimental studies were supplemented by all atom molecular dynamics simulations to provide a microscopic picture of the dendrimer-nanotube complex. The complexation was achieved through charge transfer and hydrophobic interactions, aided by multitude of oxygen, nitrogen, and n-propyl moieties of the dendrimer.

36 MATERIALS SCIENCE↗