Search NASA⌕ Search

Engineering topics

Kumar, Vineet [ORNL] (ORCID:000000029240025X)

Publications and source records attributed to Kumar, Vineet [ORNL] (ORCID:000000029240025X).

LC-Opt: Benchmarking Reinforcement Learning and Agentic AI for End-to-End Liquid Cooling Optimization in Data Centers

Liquid cooling is critical for thermal management in high-density data centers with the rising AI workloads. However, machine learning-based controllers are essential to unlock greater energy efficiency and reliability, promoting sustainability. We present LC-Opt, a Sustainable Liquid Cooling (LC) benchmark environment, for reinforcement learning (RL) control strategies in energy-efficient liquid cooling of high-performance computing (HPC) systems. Built on the baseline of a high-fidelity digital twin of Oak Ridge National Lab's Frontier Supercomputer cooling system, LC-Opt provides detailed Modelica-based end-to-end models spanning site-level cooling towers to data center cabinets and server blade groups. RL agents optimize critical thermal controls like liquid supply temperature, flow rate, and granular valve actuation at the IT cabinet level, as well as cooling tower (CT) setpoints through a Gymnasium interface, with dynamic changes in workloads. This environment creates a multi-objective real-time optimization challenge balancing local thermal regulation and global energy efficiency, and also supports additional components like a heat recovery unit (HRU). We benchmark centralized and decentralized multi-agent RL approaches, demonstrate policy distillation into decision and regression trees for interpretable control, and explore LLM-based methods that explain control actions in natural language through an agentic mesh architecture designed to foster user trust and simplify system management. LC-Opt democratizes access to detailed, customizable liquid cooling models, enabling the ML community, operators, and vendors to develop sustainable data center liquid cooling control solutions.

Naug, Avisek [Hewlett Packard Enterprise]↗

Computational Modeling of a 3D Printed Recuperator and Subsequent Experimental Loop for Supercritical Carbon Dioxide Cycles

Oak Ridge National Laboratory (ORNL), in collaboration with mechanical-thermal energy storage (mTES) provider EarthEn, a US Department of Energy (DOE) Lab-Embedded Entrepreneurship Program (LEEP) recipient at ORNL’s Innovation Crossroads 2023, is utilizing a state-of-the-art patented 3D printing technique to design an additively manufactured (AM) supercritical CO2 (sCO2) recuperator (REC) for EarthEn’s charge/discharge cycle. The AM REC will be printed at ORNL’s Manufacturing Demonstration Facility using Inconel Alloy 718 and tested on a closed-loop, ∼100 kW scale experimental facility that is under construction. The testing will compare the printed design against a commercial-off-the-shelf Printed Circuit Heat Exchanger (PCHE) REC. The design of the sCO2 facility is guided by a Modelica-based system model which is primarily dependent on the open-source TRANSFORM library developed at ORNL and uses the open-source CoolProp library for thermophysical properties of sCO2 via the External Media library. It is envisioned that an iterative process will be followed between the physical loop and the system model wherein the initial experimental data will be used to tune the model, which in turn will be used to guide future loop operation. Simultaneously, the AM REC is being designed using computer-aided design models, and it is also being analyzed for hydraulic and thermomechanical response using commercial computational fluid dynamics software, Simcenter STAR-CCM+, on highperformance computing resources.1

See, Nate [ORNL] (ORCID:0000000178581202)↗

Assessment of CTF for Steady-state and Transient Post-CHF Conditions in Support of Time-at-Temperature Modeling Applications

The US nuclear industry is exploring options to improve operational economics and uprate the current fleet of light-water reactors by investigating transitioning to cladding performance–based safety criteria as opposed to the current limit, which requires complete avoidance of critical heat flux (CHF)/dryout. Past experience has shown that not all events leading to a dryout are severe enough to cause fuel performance degradation. Allowing temporary dryout of the fuel—that is, using a time-at-temperature (TaT) strategy—could allow for economic improvements via large power uprates and enhanced operational flexibility for current plants without compromising fuel integrity. To support this effort, the US Department of Energy is executing a comprehensive program that includes generating cladding material data under TaT conditions, developing new mechanistic models, and demonstrating modeling and simulation capabilities for transients of interest. This paper presents work performed to assess the CTF thermal-hydraulics subchannel code. CTF is a package used in the VERA core simulator, which will ultimately be used for TaT analysis. CTF will provide the thermal-hydraulic boundary conditions that will be needed for fuel performance analysis in the BISON code. Quantifying both the accuracy and uncertainty of post-CHF models will therefore be necessary. This paper outlines the strategy for the assessment of TaT and presents the results of using the steady-state and transient dryout experiments of the Boiling Fine-mesh Bundle Tests for CTF validation. The results show that the current model tends to overpredict steady-state critical power. This behavior translates to the transient tests, in which CTF is unable to capture transient dryout behavior. Some discussion of sensitivity analysis work being performed is provided to indicate which models must be further analyzed to properly model transient dryout and its uncertainty.

Salko Jr, Robert [ORNL] (ORCID:0000000253566679)↗