Development of ultrastable filters and lasers for solar seismology

The Stable Solar Analyzer is a recently developed instrument for the measurement of solar magnetic fields and surface velocities that is being employed at the U.S. National Solar Observatory to study the subsurface convection cells of the sun and the structure of surface and subsurface magnetic fields. The Analyzer is expected to ultimately be flown aboard such spacecraft as the ESA/NASA Solar and Heliospheric Observatory. This instrument is based on a crystalline lithium niobate Fabry-Perot filter that is used in conjunction with a stabilized laser that furnishes an absolute wavelength reference; this laser Fabry-Perot combination has achieved wavelength stabilities of the order of 2 parts in 10 to the 10th, over a six-hour interval.

Rust, D. M.↗

The NASA/GSFC hydrogen maser program: A review of recent data

Data is presented on the phase and frequency stability, over time periods extending to one week, of the new NR field operable hydrogen masers developed by the Applied Physics Laboratory (APL) and the older NX and NP field operable hydrogen masers developed by Goddard Space Flight Center and maintained and upgraded by Bendix Field Engineering Corporation (BFEC). Data is presented on the NR masers in the laboratory showing frequency stabilities well into the 10 to the -15th power range and phase stabilities well into the 100 ps range for periods of up to one day. Data is presented on upgraded NP masers in the laboratory showing that the frequency stability has been improved substantially to virtually the NR level. VLBI data is presented on the phase difference between NX-2 at Owens Valley, California and NR-2 at Fort Davis, Texas for a one week period showing, after removal of a constant frequency drift, a 350 ps RMS phase stability.

Chiu, M.↗

Hydrogen maser development at Laval University

The physical construction of two hydrogen masers is described and results of measurements made on one of the masers are given. These include: cavity Q, thermal time constant, line Q, signal power output, magnetic shielding factor. Preliminary results indicate that the frequency stability will be mainly affected by the thermal of the cavity. The magnetic field and the barometric fluctuations should not affect the maser at the stability level above a few parts in 10 to the 15th power, which is the goal for averaging times of several hours.

Vanier, J.↗