Search NASA⌕ Search

Engineering topics

Kuo, Chao-Lin

Publications and source records attributed to Kuo, Chao-Lin.

High-volume tunable resonator for axion searches above 7 GHz

In this research, we present results from an experimental demonstration of a tunable thin-shell axion haloscope whose geometry decouples its overall volume from its resonant frequency, thereby evading the steep sensitivity degradation at high frequencies. An aluminum 2.6-l (41⁢λ 3 ) prototype, which tunes from 7.1 to 8.0 GHz, was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable TM 010 mode is clearly identified with a room-temperature quality factor, Q, of approximately 5000. The on-resonance E-field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of 0.57 across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume V $\gg$ λ 3 . We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the postinflationary axion parameter space (approximately 4 to 30 GHz) at Dine-Fischler-Srednicki-Zhitnitsky sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Filamentary Dust Polarization and the Morphology of Neutral Hydrogen Structures

Filamentary structures in neutral hydrogen (H$\tiny{I}$) emission are well aligned with the interstellar magnetic field, so H$\tiny{I}$ emission morphology can be used to construct templates that strongly correlate with measurements of polarized thermal dust emission. We explore how the quantification of filament morphology affects this correlation. We introduce a new implementation of the Rolling Hough Transform (RHT) using spherical harmonic convolutions, which enables efficient quantification of filamentary structure on the sphere. We use this Spherical RHT algorithm along with a Hessian-based method to construct H$\tiny{I}$-based polarization templates. We discuss improvements to each algorithm relative to similar implementations in the literature and compare their outputs. By exploring the parameter space of filament morphologies with the Spherical RHT, we find that the most informative H$\tiny{I}$ structures for modeling the magnetic field structure are the thinnest resolved filaments. For this reason, we find a ~10% enhancement in the B-mode correlation with polarized dust emission with higher-resolution H$\tiny{I}$ observations. We demonstrate that certain interstellar morphologies can produce parity-violating signatures, i.e., nonzero TB and EB, even under the assumption that filaments are locally aligned with the magnetic field. Finally, we demonstrate that B modes from interstellar dust filaments are mostly affected by the topology of the filaments with respect to one another and their relative polarized intensities, whereas E modes are mostly sensitive to the shapes of individual filaments.

79 ASTRONOMY AND ASTROPHYSICS↗

SLAC microresonator RF(SMuRF) electronics: A tone-tracking readout system for superconducting microwave resonator arrays

Here, we describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems, such as microwave superconducting quantum interference device multiplexers (μmux) or microwave kinetic inductance detectors. Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4–8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here, we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. In particular, we focus on the case of large-channel-count, low-bandwidth applications, but the system has been easily reconfigured for high-bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

47 OTHER INSTRUMENTATION↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Symmetrically tuned large-volume conic shell-cavities for axion searches

In an earlier paper [1], a new class of thin-shell cavities were proposed to evade the steep frequency scaling of conventional axion haloscopes. In this follow-up work, we see that a generalized conic geometry enables robust frequency-tuning for these large-volume cm-wave cavities. The frequency-defining dimension of a conic shell-cavity changes symmetrically and uniformly during tuning, maintaining a high axion coupling efficiency (the "form factor") to an external solenoid field. It is further shown that such tunable geometry is not restricted to circular cones. A general prescription for arbitrary volume-filling conic shell-cavities is developed and direct solutions are obtained for the created numerical models. Additionally, the largest of the realized designs is a meandering "brain" cavity that is tunable over a frequency range of 20%. The scan rate of this cavity is three orders of magnitude larger than that of a scaled cylindrical cavity used in the current generation experiments. The prospects for such a large improvement in the scan rate should motivate R& D efforts in fabrication and other implementation techniques. If these engineering challenges can be met, cavity-based axion haloscopes can stay competitive at frequencies higher than a few GHz. We propose an experimental configuration at 20 GHz (~80 μeV) using an array of brain cavities and compare it with other proposals for similar frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Large-volume centimeter-wave cavities for axion searches

The scan rate of an axion haloscope is proportional to the square of the cavity volume. In this paper, a new class of thin-shell cavities are proposed to search for axionic dark matter. These cavities feature active volume much larger (>20×) than that of a conventional cylindrical haloscope, comparable quality factor Q, and a similar frequency tuning range. Furthermore, full 3D numerical finite-element analyses have been used to show that the TM 010 eigenmodes are singly polarized throughout the volume of the cavity and can facilitate axion-photon conversion in uniform magnetic field produced by a superconducting solenoid. To mitigate spurious mode crowding and volume losses due to localization, a pre-amplification binary summing network will be used for coupling. Because of the favorable frequency-scaling, the new cavities are most suitable for centimeter-wavelength (~ 10–100 GHz), corresponding to the promising post-inflation axion production window. In this frequency range, the tight machining tolerances required for high-Q thin-shell cavities are achievable with standard machining techniques for near-infrared mirrors.

79 ASTRONOMY AND ASTROPHYSICS↗

BICEP2/SPUD: Searching for Inflation with Degree Scale Polarimetry from the South Pole

BICEP2/SPUD is the new powerful upgrade of the existing BICEP1 experiment, a bolometric receiver to study the polarization of the cosmic microwave background radiation, which has been in operation at the South Pole since January 2006. BICEP2 will provide an improvement up to 10 times mapping speed at 150 GHz compared to BICEP1, using the same BICEP telescope mount. SPUD, a series of compact, mechanically-cooled receivers deployed on the DASI mount at the Pole, will provide similar mapping speed in to BICEP2 in three bands, 100, 150, and 220 GHz. The new system will use large TES focal plane arrays to provide unprecedented sensitivity and excellent control of foreground contamination.

polarization↗