Search NASA⌕ Search

Engineering topics

Kuzikov, Sergey

Publications and source records attributed to Kuzikov, Sergey.

Toward Emittance Measurements at 11.7 GHz Short-Pulse High-Gradient RF Gun

A short pulse high gradient RF gun has been recently tested at Argonne Wakefield Accelerator (AWA) facility. The carried-out test showed that the 1,5-cell gun was able to inject 3 MeV, up to 100 pC bunches at room tem-perature being fed by 9 ns up to 300 MW 11.7 GHz puls-es. The cathode field was as high as about 400 MV/m. So high field is aimed to mitigate repealing Coulomb forces substantially. In accordance with simulations the emit-tance could be as low as less than 0.2 mcm. To obtain so low emittance in the experiment, the gun is assumed to be equipped with a downstream linac to be fed from the same power extractor as the gun itself. Here we report design of the RF power distribution system splitting RF power among the gun and the linac, results of low-power tests, and emittance measurement plans for upcoming new experiment at AWA.

43 PARTICLE ACCELERATORS↗

A Method for In-Situ Q₀ Measurements of High-Quality SRF Resonators

Accelerator projects such as LCLS-II naturally require low-loss superconducting (SRF) cavities. Due to strong demand for improving intrinsic quality factor (Q₀), importance of accurate cavity characterization increases. We propose a method to measure Q₀ in situ for an SRF resonator installed in its cryogenic module and connected with a RF feed source via a fixed RF coupler. The method exploits measurements of a response for an SRF resonator fed by an amplitude-modulated signal. Such a signal can be synthesized as a beat-wave composed of two frequencies that are close to the resonant frequency. Analyzing the envelope of the reflected signal, one can find the difference in reflection for the chosen frequencies and use them to compute the intrinsic Q. We also develop the methodology to carry out measurements of Q₀ at the nominal cavity operating voltage. We verified our method in experiments with a room temperature copper resonator and with two SRF resonators including Fermilab’s 650 MHz cavity and JLab’s 1500 MHz cavity.

43 PARTICLE ACCELERATORS↗

A Fast Mechanical Tuner for SRF Cavities

There is a particular need for fast tuners and phase shifters for advanced superconducting accelerator RF systems. The tuners based on ferrite, ferroelectric and piezo materials are commonly used. However, those methods suffer from one or another issue of high power loss, slow response, and narrow tuning range. We propose a robust, fast (up to ~5 MHz/sec), high efficient mechanical tuner for SRF cavities operating at the frequency 50 MHz. We develop an external mechanical tuner that is strongly coupled to the cavity. The tuner design represents a trade-off of high efficiency (low RF losses and low heat flux) and frequency tunability range. Our approach solves this trade-off issue. We propose RF design which exploits two coupled resonators so that a main high-field cavity is controlled with a small tunable resonator with a flexible metallic wall operating in a relatively low RF field. Simulations, carried out for a 7.5 MV/m 50 MHz SRF Quarter Wave Resonator (QWR), show that frequency tunability at level 10⁻³ is obtainable.

43 PARTICLE ACCELERATORS↗

An X-Band Ultra-High Gradient Photoinjector

High brightness beams appealing for XFELs and UEM essentially imply a high current and a low emittance. To obtain such beams we propose to raise the accelerating voltage in the gun mitigating repealing Coulomb forces. An ultra-high gradient is achieved utilizing a short-pulse technology. We have designed a room temperature X-band 1,5 cell gun that is able to inject 4 MeV, 100 pC bunches with as low as 0.15 mcm normalized transverse emittance. The gun is operated with as high gradients as 400 MV/m and fed by 200 MW, 10 ns RF pulses generated with Argonne Wakefield Accelerator (AWA) power extractor. We report results of low RF power tests, laser alignment test results, and successful gun conditioning results carried out at nominal RF power.

43 PARTICLE ACCELERATORS↗

High Gradient High Shunt Impedance Accelerating Structure

develop an inexpensive accelerating structure with a high gradient and high shunt impedance. Euclid Techlabs proposes to optimize this technology (based on a successful accelerating structure with distributed coupling developed at SLAC) for industrial applications and serial production. Future colliders require high gradient and high efficiency accelerating structures (high shunt impedance). The SLAC accelerator laboratory recently developed a series of accelerating structures with distributed coupling. Such a structure includes one or more parallel waveguides which are loaded by accelerating cavities. This approach allows configurations where no RF power is flowing axially through the accelerating cavity while maintaining a traveling RF wave through the cross-section of the accelerating structure. In this case the accelerating cavities are isolated at the beam pipe. Conventional traveling wave structures typically couple the RF power through the beam pipe. This feature constrains the cavity shunt impedance to relatively small values. For this reason, the distributed coupling design improves efficiency while reducing cost and improving the operational flexibility of particle accelerators. High gradient operation poses the risk of having a high breakdown rates. In traditional standing and traveling wave structures, RF power flows through the accelerating cells. For distributed coupling structures, this risk is reduced because the absence of power flow through the accelerating cavity allows configurations where no power flows through the beam pipe. Finally, the distributed coupling accelerating structure design allows fabricating structures in two halves. This significantly reduces the complexity of machining, brazing and tuning.

43 PARTICLE ACCELERATORS↗

Tapered Flying RF Undulator

The x-ray free electron laser (x-FEL) efficiency, measured as a fraction of the electron beam power converted into light, is typically below 0.1% for most of the x-FEL facilities presently in operation. Undulator tapering techniques can be used to improve the conversion efficiency by 1-2 orders of magnitude. At present there are no robust tapered undulator x-FEL schemes operating at 10% efficiency. Such development will be a breakthrough for the x-FEL community.

43 PARTICLE ACCELERATORS↗

Electrodeless, Non-Invasive X-Ray Flux Monitor

Flux monitoring is a must at modern x-ray light sources for alignment, measurement feedback and calibration. Dedicated x-ray flux monitors occupy space, absorb part of the beam and cannot be easily relocated. At the same time numerous x-ray beamline elements (vacuum windows, monochromators, refractive lenses, zone plates to name a few) inevitably absorb portion of the x-ray beam which is proportional to incoming flux. At present there are no devices which can measure flux non-invasively based on this parasitic absorption

43 PARTICLE ACCELERATORS↗

A 12 GHz RF Power Source for the CLIC Study

The CLIC RF frequency has been changed in 2008 from the initial 30 GHz to the European X-band 11.9942 GHz permitting beam independent power production using klystrons for CLIC accelerating structure testing. A design and fabrication contract for five klystrons at that frequency has been signed by different parties with SLAC. France (IRFU, CEA Saclay) is contributing a solid state modulator purchased in industry and specific 12 GHz RF network components to the CLIC study. RF pulses over 120 MW peak at 230 ns length will be obtained by using a novel SLED-I type pulse compression scheme designed and fabricated by IAP, Nizhny Novgorod, Russia. The X-band power test stand is being installed in the CLIC Test Facility CTF3 for independent structure and component testing in a bunker, but allowing, in a later stage, for powering RF components in the CTF3 beam lines. The design of the facility, results from commissioning of the RF power source and the expected performance of the Test Facility are reported.

43 PARTICLE ACCELERATORS↗