STATUS OF THE NEUTRALIZED DRIFT COMPRESSION EXPERIMENT (NDCX-II)

The Neutralized Drift Compression Experiment (NDCX-II) is an 11 M$ induction accelerator project currently in construction at Lawrence Berkeley National Laboratory for warm dense matter (WDM) experiments investigating the interaction of ion beams with matter at elevated temperature and pressure. The machine consists of a lithium injector, induction accelerator cells, diagnostic cells, a neutralized drift compression line, a final focus solenoid, and a target chamber. The induction cells and some of the pulsed power systems have been reused from the decommissioned Advanced Test Accelerator at Lawrence Livermore National Laboratory after refurbishment and modification. The machine relies on a sequence of acceleration waveforms to longitudinally compress the initial ion pulse from 600 ns to less than 1 ns in {approx} 12 m. Radial confinement of the beam is achieved with 2.5 T pulsed solenoids. In the initial hardware configuration, 50 nC of Li{sup +} will be accelerated to 1.25 MeV and allowed to drift-compress to a peak current of {approx}40 A. The project started in the summer of 2009. Construction of the accelerator will be completed in the fall of 2011 and will provide a worldwide unique opportunity for ion-driven warm dense matter experiments as well as research related to novel beam manipulations for heavy ion fusion drivers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NDCX-II, an Induction Linac for HEDP and IFE Research

The Heavy Ion Fusion Science Virtual National Laboratory in the USA is constructing a new Neutralized Drift Compression eXperiment (NDCX-II) at LBNL. This facility is being developed for high energy density physics and inertial fusion energy research. The 12 m long induction linac in NDCX-II will produce a Li{sup +} beam pulse, at energies of 1.2-3 MeV, to heat target material to the warm dense matter regime ({approx} 1 eV). By making use of special acceleration voltage waveforms, 2.5T solenoid focusing, and neutralized drift compression, 20 - 50 nC of beam charge from the ion source will be compressed longitudinally and radially to achieve a subnanosecond pulse length and mm-scale target spot size. The original Neutralized Drift Compression Experiment (NDCX-I) has successfully demonstrated simultaneous radial and longitudinal compression by imparting a velocity ramp to the ion beam, which then drifts in a neutralizing plasma to and through the final focussing solenoid and onto the target. At higher kinetic energy and current, NDCX-II will offer more than 100 times the peak energy fluence on target of NDCX-I. NDCX-II makes use of many parts from the decommissioned Advanced Test Accelerator (ATA) at LLNL. It includes 27 lattice periods between the injector and the neutralized drift compression section (Figure 1). There are 12 energized induction cells, 9 inactive cells which provide drift space, and 6 diagnostic cells which provide beam diagnostics and pumping. Custom pulsed power systems generate ramped waveforms for the first 7 induction cells, so as to quickly compress the beam from 600 ns at the injector down to 70 ns. After this compression, the high voltages of the ATA Blumleins are then used to rapidly add energy to the beam. The Blumleins were designed to match the ferrite core volt-seconds with pulses up to 250 kV and a fixed FWHM of 70 ns. The machine is limited to a pulse repetition rate of once every 20 seconds due to cooling requirements. The NDCX-II beam is highly space-charge dominated. The 1-D ASP code was used to synthesize high voltage waveform for acceleration, while the 3-D Warp particle-in-cell code was used for detailed design of the lattice. The Li{sup +} ion was chosen because its Bragg Peak energy (at {approx} 2 MeV) coincides with the NDCX-II beam energy. The 130 keV injector will have a 10.9 cm diameter ion source. Testing of small (0.64 cm diameter) lithium doped alumino-silicate ion sources has demonstrated the current density ({approx} 1 mA/cm{sup 2}) used in the design, with acceptable lifetime. A 7.6 cm diameter source has been successfully produced to verify that the coating method can be applied to such a large emitting area. The ion source will operate at {approx} 1275 C; thus a significant effort was made in the design to manage the 4 kW heating power and the associated cooling requirements. In modifying the ATA induction cells for NDCX-II, the low-field DC solenoids were replaced with 2.5 T pulsed solenoids. The beam pipe diameter was decreased in order to reduce the axial extent of the solenoid fringe fields and to make room for water cooling. In addition, an outer copper cylinder (water-cooled) was used to exclude the solenoid magnetic flux from the ferrite cores. Precise alignment is essential because the beam has a large energy spread due to the rapid pulse compression, such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. A novel pulsed-wire measurement method is used to align the pulsed solenoid magnets. Alignment accuracy has been demonstrated to within 100 {micro}m of the induction cell axis. The neutralized drift compression region after the last induction cell is approximately 1.2 m long and includes ferroelectric plasma sources (FEPS) fabricated by PPPL similar to those successfully operating in NDCX-I. The 8-T final focus pulsed solenoid, filtered cathodic arc plasma sources (FCAPS), and target chamber from NDCX-I are to be relocated to NDCX-II. The NDCX-II project started in July 2009 and is expected to complete in fall of 2011. As future funds become available, additional induction cells and pulsed power systems will be added to increase the beam energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Li+ alumino-silicate ion source development for the Neutralized Drift Compression Experiment (NDCX-II)

To heat targets to electron-volt temperatures for the study of warm dense matter with intense ion beams, low mass ions, such as lithium, have an energy loss peak (dE/dx) at a suitable kinetic energy. The Heavy Ion Fusion Sciences (HIFS) program at Lawrence Berkeley National Laboratory will carry out warm dense matter experiments using Li{sup +} ion beam with energy 1.2-4 MeV in order to achieve uniform heating up to 0.1-1 eV. The accelerator physics design of Neutralized Drift Compression Experiment (NDCX-II) has a pulse length at the ion source of about 0.5 {micro}s. Thus for producing 50 nC of beam charge, the required beam current is about 100 mA. Focusability requires a normalized (edge) emittance {approx}2 {pi}-mm-mrad. Here, lithium aluminosilicate ion sources, of {beta}-eucryptite, are being studied within the scope of NDCX-II construction. Several small (0.64 cm diameter) lithium aluminosilicate ion sources, on 70%-80% porous tungsten substrate, were operated in a pulsed mode. The distance between the source surface and the mid-plane of the extraction electrode (1 cm diameter aperture) was 1.48 cm. The source surface temperature was at 1220 C to 1300 C. A 5-6 {micro}s long beam pulsed was recorded by a Faraday cup (+300 V on the collector plate and -300 V on the suppressor ring). Figure 1 shows measured beam current density (J) vs. V{sup 3/2}. A space-charge limited beam density of {approx}1 mA/cm{sup 2} was measured at 1275 C temperature, after allowing a conditioning time of about {approx} 12 hours. Maximum emission limited beam current density of {ge} 1.8mA/cm{sup 2} was recorded at 1300 C with 10-kV extractions. Figure 2 shows the lifetime of two typical sources with space-charge limited beam current emission at a lower extraction voltage (1.75 kV) and at temperature of 1265 {+-} 7 C. These data demonstrate a constant, space-charge limited beam current for 20-50 hours. The lifetime of a source is determined by the loss of lithium from the alumino-silicate material either as ions or as neutral atoms. Our measurements suggest that for the low duty factor ({approx}10{sup -8}) required for NDCX-II, the lifetime of an emitter depends mostly on the duration that the emitter spends at elevated temperature, that is, at {ge} 1250 C. At this temperature, lithium loss is due mostly to neutral loss (not charged ion extraction). Extension of the lifetime of the source may be possible by lowering the temperature between beam pulses, when the idling time is sufficiently long between shots. The NDCX-II design seeks to operate the ion source at the maximum current density without running into heat management and lifetime problems. In preparation to fabricate a large (10.9 cm in diameter) source for the NDCXII experiment, recently a 7.6 cm diameter source has been fabricated. The method of fabrication of this larger source is similar to that of fabrication of a 6.3mm diameter source, except a longer furnace heating time was used due to mass differences. NDCX-II construction is in progress. Progress of lithium source study for NDCX-II is available in literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic Alignment of Pulsed Solenoids Using the Pulsed Wire Method

A unique application of the pulsed-wire measurement method has been implemented for alignment of 2.5 T pulsed solenoid magnets. The magnetic axis measurement has been shown to have a resolution of better than 25 {micro}m. The accuracy of the technique allows for the identification of inherent field errors due to, for example, the winding layer transitions and the current leads. The alignment system is developed for the induction accelerator NDCX-II under construction at LBNL, an upgraded Neutralized Drift Compression experiment for research on warm dense matter and heavy ion fusion. Precise alignment is essential for NDCX-II, since the ion beam has a large energy spread associated with the rapid pulse compression such that misalignments lead to corkscrew deformation of the beam and reduced intensity at focus. The ability to align the magnetic axis of the pulsed solenoids to within 100 pm of the induction cell axis has been demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

INERTIAL FUSION DRIVEN BY INTENSE HEAVY-ION BEAMS

Intense heavy-ion beams have long been considered a promising driver option for inertial-fusion energy production. This paper briefly compares inertial confinement fusion (ICF) to the more-familiar magnetic-confinement approach and presents some advantages of using beams of heavy ions to drive ICF instead of lasers. Key design choices in heavy-ion fusion (HIF) facilities are discussed, particularly the type of accelerator. We then review experiments carried out at Lawrence Berkeley National Laboratory (LBNL) over the past thirty years to understand various aspects of HIF driver physics. A brief review follows of present HIF research in the US and abroad, focusing on a new facility, NDCX-II, being built at LBNL to study the physics of warm dense matter heated by ions, as well as aspects of HIF target physics. Future research directions are briefly summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heavy Ion Inertial Fusion Energy: Summaries of Program Elements

The goal of the Heavy Ion Fusion (HIF) Program is to apply high-current accelerator technology to IFE power production. Ion beams of mass {approx}100 amu and kinetic energy {>=} 1 GeV provide efficient energy coupling into matter, and HIF enjoys R&D-supported favorable attributes of: (1) the driver, projected to be robust and efficient; see 'Heavy Ion Accelerator Drivers.'; (2) the targets, which span a continuum from full direct to full indirect drive (and perhaps fast ignition), and have metal exteriors that enable injection at {approx}10 Hz; see 'IFE Target Designs'; (3) the near-classical ion energy deposition in the targets; see 'Beam-Plasma Interactions'; (4) the magnetic final lens, robust against damage; see 'Final Optics-Heavy Ion Beams'; and (5) the fusion chamber, which may use neutronically-thick liquids; see 'Liquid-Wall Chambers.' Most studies of HIF power plants have assumed indirect drive and thick liquid wall protection, but other options are possible.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Li{sup +} ion emission from a hot-plate alumina-silicate source stimulated by flash heating with an infrared laser

The Neutralized Drift Compression Experiment-II accelerator under construction at Lawrence Berkeley National Laboratory has been designed to employ a lithium-doped alumino-silicate (Al-Si) hot-plate surface-ionization ion source. In order to achieve the design 1 mA/cm{sup 2} current density, the emitter must be constantly kept at a high temperature, leading to the accelerated loss of Li material as ions or neutrals. As a result, the estimated lifetime of the source is 50 h. This lifetime can be extended if the source is kept at low temperature during standby, and pulse heated to the high temperature during the ion extraction phase only. A pulsed heating technique based on an infrared laser (CO{sub 2} gas discharge, {lambda}= 10.6 {mu}m) is described in this paper. The feasibility of ion current emission stimulated by flash heating with an infrared (IR) laser was demonstrated. High repeatability of the laser-stimulated ion current was observed, creating an opportunity for modulation and gating of the ion current with a laser pulse. It was found that with the available low power ({approx_equal}115 W/cm{sup 2}) IR laser, current densities as high as 0.8 mA/cm{sup 2} could be achieved with a 2.8 mm diameter source. Various approaches for scaling to a larger (10 cm diameter) source and the application of short pulse, high power lasers are discussed. The results and conclusions of this paper may apply to various species of hot-plate ion sources.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Beam dynamics of the Neutralized Drift Compression Experiment-II, a novel pulse-compressing ion accelerator

Intense beams of heavy ions are well suited for heating matter to regimes of emerging interest. A new facility, NDCX-II, will enable studies of warm dense matter at approx1 eV and near-solid density, and of heavy-ion inertial fusion target physics relevant to electric power production. For these applications the beam must deposit its energy rapidly, before the target can expand significantly. To form such pulses, ion beams are temporally compressed in neutralizing plasma; current amplification factors of approx50-100 are routinely obtained on the Neutralized Drift Compression Experiment (NDCX) at the Lawrence Berkeley National Laboratory. In the NDCX-II physics design, an initial non-neutralized compression renders the pulse short enough that existing high-voltage pulsed power can be employed. This compression is first halted and then reversed by the beam's longitudinal space-charge field. Downstream induction cells provide acceleration and impose the head-to-tail velocity gradient that leads to the final neutralized compression onto the target. This paper describes the discrete-particle simulation models (one-, two-, and three-dimensional) employed and the space-charge-dominated beam dynamics being realized.

43 PARTICLE ACCELERATORS↗

A tandem-based compact dual-energy gamma generator

A dual-energy tandem-type gamma generator has been developed at E. O. Lawrence Berkeley National Laboratory and Sandia National Laboratories. The tandem accelerator geometry allows higher energy nuclear reactions to be reached, thereby allowing more flexible generation of MeV-energy gammas for active interrogation applications. Both positively charged ions and atoms of hydrogen are created from negative ions via a gas stripper. In this paper, we show first results of the working tandem-based gamma generator and that a gas stripper can be utilized in a compact source design. Preliminary results of monoenergetic gamma production are shown.

43 PARTICLE ACCELERATORS↗

Sealed operation of a rf driven ion source for a compact neutron generator to be used for associated particle imaging

We present the recent development of a prototype compact neutron generator to be used in conjunction with the method of associated particle imaging for the purpose of active neutron interrogation. In this paper, the performance and device specifications of these compact generators that employ rf driven ion sources will be discussed. Initial measurements of the generator performance include a beam spot size of 1 mm in diameter and a neutron yield of 2x10{sup 5} n/s with air cooling.

43 PARTICLE ACCELERATORS↗

Radio frequency-driven proton source with a back-streaming electron dump

This article describes an rf ion source with a back-streaming electron dump. A quartz tube, brazed to a metal plug at one end, is fused in the center of a flat quartz plate. rf power (at 13.6 MHz) is coupled to generate hydrogen plasma using a planar external antenna bonded to the window. Bonding the water-cooled rf antenna to the quartz window significantly lowers its temperature. The water-cooled metal plug serves as the back-streaming electron dump. At 1800 W, the current density of extracted hydrogen ions reaches approximately 125 mA/cm{sup 2}.