Modeling and Simulation of the Angel Upper Limb Offload Device: Branching Into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson

Modeling and Simulation of The Angel Upper Limb Offload Device: Branching into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson

Modeling and Simulation Efforts to Support Improved Comfort in ARGOS

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch, and here we present preliminary modeling of that device using the open-source biomechanical tool OpenSim [1,2] with an in-house developed plugin. We analyze a series of motions performed by a single shirt-sleeved subject with goals of characterizing the device, validating the model, and predicting whether reduced gravity conditions (i.e., lunar gravity (Lg) or Martian gravity (Mg)) can be accurately simulated with the device, as well as providing comfort to the ARGOS user. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are either obtained from (1) inverse kinematics (IK) using motion capture markers on the various components of the device or (2) calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. Given the joint angles of the device, the resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) in order to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data and the forces from manual measurements of the spring both independently and integrated within the device. We found that calculated joint angles generally represent the angles measured and computed with IK, supporting a possible analysis workflow inputting human motion data and observing system behavior under varied design parameters. In two different device configurations in which the maximum applied force was 131 N, our current model accurately captured force with a difference of 2-3 N from measured loads. Though our initial test was performed with a shirt-sleeve subject, arm weights were added to emulate the weight of the suit sleeve and the subject was positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup. Arm range of motion tasks were performed outside of the HUT, inside the HUT, and inside the HUT while using the device. A variety of other upper body tasks were completed as well. In summary, we have developed a model to investigate and verify an upper limb offload device currently in development. We believe this model will be a valuable tool not only for device characterization but also to predict proper configurations to simulate Lg or Mg conditions, investigate range of motion concerns, predict limitations such as internal collisions and contacts, and inform future design improvements.

L B Nilsson

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

BACKGROUND As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab in NASA Johnson Space Center's (JSC) Software, Robotics, and Simulation Division, aims to address this challenge through innovative approaches. This study presents the development and evaluation of an NGED system, focusing on its adaptability to various mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). Central to this project is the application of biomechanical modeling to optimize exercise efficacy and safety in microgravity and partial gravity environments. The project is a collaborative effort with the Human Health and Performance group at Johnson Space Center, ensuring a comprehensive approach to astronaut well-being that integrates biomechanical principles with practical exercise solutions. The NGED represents the next generation of exercise capabilities for missions in space, on the Moon and Mars, with a specific focus on applications such as the LPR. METHODS AND RESULTS Data collection for NGED development was conducted with two motor-driven Beyond Power Voltra I [1] systems and a custom test structure to allow placement of the cable-based devices on the ground, at shoulder height, and overhead. The collection was performed in JSC’s Prototype Immersive Technology (PIT) Lab, utilizing an OptiTrack motion capture system and AMTI force platform, to enable detailed biomechanical analysis via OpenSim [2,3]. Motion capture data were collected for three subjects representing different body types and statures. The marker set used was an enhanced version of the full-body Plug-in Gait marker set [4], with additional markers strategically placed for the primary objective of informing exercise volume requirements. Subjects performed a series of 17 exercises, carefully selected to engage various muscle groups, including novel spaceflight exercises such as skiing (ergometer style), lateral pulldowns, wood chops, triceps extensions, and flies, with load variations ranging from 10 to 90 pounds to maintain kinematic form. This comprehensive approach allowed for a thorough evaluation of the NGED's performance across a wide range of motions and loads. The biomechanical modeling and analysis were conducted using a modified OpenSim Full Body Rajagopal Model [4,5] and also scaled to the maximum and minimum anthropometry provided in NASA-STD-3001 [6]. Volumetric convex hulls were generated based on model marker trajectories and aggregated into geometric assemblies. These can be placed in models of vehicle designs to assess fit to protect for exercise as well as to adapt NGED exercise to fit available space. Preliminary findings from the collection indicate that the NGED prototype demonstrates significant adaptability across varying user anthropometrics and exercise types. The device showed consistent performance in load-bearing exercises, with subjects able to perform exercises effectively while maintaining proper biomechanical form. CONCLUSION NGED represents a forward-looking advancement in exercise capabilities for future space missions. In the future, this system can be used to capture valuable metrics (e.g., isometric mid-thigh pull for force output measurements, assessments of postural muscle strength, overall isometric strength). Its versatility in accommodating various exercises and user physiques, coupled with the ability to provide targeted biomechanical loading, makes it a promising approach for maintaining astronaut health during long-duration missions to the Moon and Mars. Future work will focus on refining the NGED based on initial biomechanical findings, leveraging the detailed insights provided by motion capture and analysis techniques. Particular emphasis will be placed on optimizing its use within the confined spaces of a LPR and other space habitats. This work contributes significantly to NASA's goals of supporting human health and performance in deep space exploration, paving the way for sustainable long-term presence beyond Low Earth Orbit through advanced, biomechanically-informed exercise solutions.

C Wang

Developing Methods for Exercise System Kinematics Tracking

BACKGROUND How to quantify the load and forces produced by exercise equipment and their Vibration Isolation and Stabilization (VIS) platforms in-flight is an active area of investigation. Kinematic tracking paired with system modeling can provide insights as well as verification and validation of simulations used for system design and development. Traditional motion capture methods can require significant cost in equipment procurement and crew-time, but newer lessons learned can be leveraged [1]. The VIS systems of current and future exercise hardware on the International Space Station (ISS) such as the Cycle Ergometer with Vibration Isolation System (CEVIS) and the European Enhanced Exploration Exercise Device (E4D) are not currently outfitted with IMUs or similar measurement devices. Video-based methods would enable use of multi-purpose, crew-familiar flight equipment. An initial exploration of video-based solutions was performed utilizing 2-camera video from crew cycling on Teal-CEVIS on the ISS. METHODS AND RESULTS Our group has scoped a variety of video-based object tracking methods. To date, we have primarily investigated computer vision toolkits such as openCV. Techniques explored include key-point detection, background subtraction, region-of interest tracking, color-based tracking, tag masking and tracking, and corner detection. Although object-tracking and 6D pose estimation is a rich field, space applications are a unique problem that are challenging for existing software and toolkits. The majority of the existing object-tracking applications involve vehicles/pedestrians and household objects with simple backgrounds. We have identified the following features which pose particular challenges for on-station exercise equipment tracking: Busy and visually cluttered background Low-textured tracking object with relatively small motions Occlusions and motion by human subject and loose, floating objects Limited number of video cameras with no fixed global references Limited ability to add tags, markers, or visual references to the tracking object Lack of training data for Machine Learning (ML) algorithms CONCLUSION We will summarize the efficacy of techniques tested for a ground mock-trial and the on-station exercise trial. It is likely that human-in-loop feedback or a conglomerate of methods is required. ML-based methods, like those implemented for human body tracking [2], may still be a viable option, but more training data and validation is needed.

L B Nilsson

Next Generation Exercise Device (NGED): Advancing Exercise Capabilities for Future Space Missions Through Biomechanical Modeling

Background: As space exploration extends to long-duration missions on the Moon and Mars, maintaining astronaut health and fitness becomes increasingly critical. The Next Generation Exercise Device (NGED), developed and tested by the HumanWorks Lab at NASA Johnson Space Center (JSC), aims to address this challenge through innovative approaches. Objective: Development and evaluation of a NGED system, focusing on its adaptability to various Moon to Mars mission scenarios, including prospective use in a Lunar Pressurized Rover (LPR). To help inform vehicle and system requirements, an exercise volumetric assessment was performed via data collection and biomechanical modeling.