Search NASA⌕ Search

Engineering topics

La Commara, M.

Publications and source records attributed to La Commara, M..

Search for dark matter annual modulation with DarkSide-50

Dark matter may induce an event in an Earth-based detector, and its event rate is predicted to show an annual modulation as a result of the Earth’s orbital motion around the Sun. We searched for this modulation signature using the ionization signal of the DarkSide-50 liquid argon time projection chamber. No significant signature compatible with dark matter is observed in the electron recoil equivalent energy range above 40 eV ee , the lowest threshold ever achieved in such a search. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Long-term temporal stability of the DarkSide-50 dark matter detector

The stability of a dark matter detector on the timescale of a few years is a key requirement due to the large exposure needed to achieve a competitive sensitivity. It is especially crucial to enable the detector to potentially detect any annual event rate modulation, an expected dark matter signature. Here, in this work, we present the performance history of the DarkSide-50 dual-phase argon time projection chamber over its almost three-year low-radioactivity argon run. In particular, we focus on the electroluminescence signal that enables sensitivity to sub-keV energy depositions. The stability of the electroluminescence yield is found to be better than 0.5%. Finally, we show the temporal evolution of the observed event rate around the sub-keV region being consistent to the background prediction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Further investigation on the fusion of 6 Li with 209 Bi target at near-barrier energies

The complete and incomplete fusion cross sections for 6 Li+ 209 Bi were measured using the in-beam γ-ray method around the Coulomb barrier. The cross sections of (deuteron captured) incomplete fusion (ICF) products were re-quantified experimentally for this reaction system. Here, the results reveal that the ICF cross section is equivalent to that of complete fusion (CF) above the Coulomb barrier and dominant near or below the Coulomb barrier. A theoretical calculation based on the continuum discretized coupled channel (CDCC) method was performed for the aforementioned CF and ICF cross sections; the result is consistent with the experiments. The universal fusion function (UFF) was also compared with the measured CF cross section for different barrier parameters, demonstrating that the CF suppression factor is significantly influenced by the choice of potential, which can reflect both dynamic and static effects of breakup on the fusion process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for low mass dark matter in DarkSide-50: the bayesian network approach

Abstract We present a novel approach for the search of dark matter in the DarkSide-50 experiment, relying on Bayesian Networks. This method incorporates the detector response model into the likelihood function, explicitly maintaining the connection with the quantity of interest. No assumptions about the linearity of the problem or the shape of the probability distribution functions are required, and there is no need to morph signal and background spectra as a function of nuisance parameters. By expressing the problem in terms of Bayesian Networks, we have developed an inference algorithm based on a Markov Chain Monte Carlo to calculate the posterior probability. A clever description of the detector response model in terms of parametric matrices allows us to study the impact of systematic variations of any parameter on the final results. Our approach not only provides the desired information on the parameter of interest, but also potential constraints on the response model. Our results are consistent with recent published analyses and further refine the parameters of the detector response model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemics

We present here the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for mass scale production in response to the COVID-19 pandemics, to compensate for the dramatic shortage of such ventilators in many countries. This ventilator is an electro-mechanical equivalent of the old, reliable Manley Ventilator. Our design is optimized to permit large sale production in short time and at a limited cost, relying on off-the-shelf components, readily available worldwide from hardware suppliers. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. The MVM control and monitoring unit can be connected and networked via WiFi so that no additional electrical connections are necessary other than the connection to the electrical power. At this stage the MVM is not a certified medical device. Construction of the first prototypes is starting with a team of engineers, scientists and computing experts. The purpose of this paper is to disseminate the conceptual design of the MVM broadly and to solicit feedback from the scientific and medical community to speed the process of review, improvement and possible implementation.

Galbiati, C.↗

Effective field theory interactions for liquid argon target in DarkSide-50 experiment

We reanalize data collected with the DarkSide-50 experiment and recently used to set limits on the spin-independent interaction rate of weakly interacting massive particles (WIMPs) on argon nuclei with an effective field theory framework. The dataset corresponds to a total (16660 ± 270) kg d exposure using a target of low-radioactivity argon extracted from underground sources. We obtain upper limits on the effective couplings of the 12 leading operators in the nonrelativistic systematic expansion. For each effective coupling we set constraints on WIMP-nucleon cross sections, setting upper limits between 2.4×10-45 cm2 and 2.3×10-42 cm2 (8.9 ×10-45 cm2 and 6.0 ×10-42 cm2) for WIMPs of mass of 100 GeV/c2 (1000 GeV/c2) at 90% confidence level.

Agnes, P↗