Search NASA⌕ Search

Engineering topics

Lackey, Hope E.

Publications and source records attributed to Lackey, Hope E..

Quantification of Hydrogen Isotopes Utilizing Raman Spectroscopy Paired with Chemometric Analysis for Application across Multiple Systems

On-line and real-time analysis of a chemical process is a major analytical challenge that can drastically change the way the chemical industry or chemical research operates. With in situ analyses, new and powerful understanding of chemistry can be gained; however, building robust tools for long-term monitoring faces many challenges that include compensating for instrument drift, instrument replacement, and sensor or probe replacement. Accounting for these changes by recollecting calibration data and rebuilding quantification models can be costly and time consuming. Here, in this study, methods to overcome these challenges are demonstrated with an application of Raman spectroscopy to monitoring hydrogen isotopes with varied speciation within dynamic gas streams. Specifically, chemical data science tools such as chemometric modeling are leveraged along with several examples of calibration transfer approaches. Furthermore, the optimization of instrument and sensors cell parameters for targeted gas phase analyses is discussed. While the particular focus on hydrogen is highly beneficial within the nuclear energy sector, mechanisms built and demonstrated here are widely applicable to optical spectroscopy monitoring in numerous other chemical systems that can be leveraged in other hazardous processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical Guide to Chemometric Analysis of Optical Spectroscopic Data

The methodology and mathematical treatment of several classic multivariate methods for the analysis of spectroscopic data is demonstrated in a straightforward way that can be used as a basis for teaching an undergraduate introductory course on chemometric analysis. The multivariate techniques of classical least squares (CLS), principal component regression (PCR), and partial least squares (PLS), as well as the univariate Beer’s law method have been described and compared, building students’ understanding by starting with the univariate method and progressing step by step into the multivariate methods. Equations for the production of regression vectors from training set spectral data is described and their use demonstrated for the prediction of constituent concentrations on a separate validation set of spectra. Extreme care is taken to ensure consistency in variable formatting of data matrices. This provides a key foundation to understanding how spectral data are manipulated using these different mathematical approaches for building quantitative regression models. Each method is applied to a real-world data set, and the results are discussed to show students the types of information that can be gleaned from each method. A training set comprised of 20 infrared absorbance spectra containing 3 constituents (benzene, polystyrene, and gasoline) of known composition are used to demonstrate the matrix operations for each regression method. A separate set of 12 real-world napalm samples (containing benzene, polystyrene and gasoline) are used as a validation set to demonstrate the ability to utilize the regression models on an unknown dataset. A toolbox (PNNL Chemometric Toolbox) written in MATLAB language is supplied in the Supplemental Information file and can be used as a companion for understanding the development and deployment of the chemometric algorithms described in this paper. The datasets of the infrared spectra are also supplied, allowing users to build and inspect the chemometric models on their own. Finally, the Toolbox includes scripts to assist users in loading their own datasets into MATLAB and performing CLS, PCR, and PLS on their data.

Upper-Division Undergraduate, Analytical Chemistry↗

Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams

Processing nuclear waste from sites such as Hanford is a significant environmental cleanup need while being a significant logistical challenge. Integration of process monitoring tools, that can provide in situ and real-time feedback about the process, can significantly alleviate needs to collect grab samples for process control and product characterization. Raman spectroscopy paired with chemometric analysis is one process monitoring tool that can provide chemical composition information on a large number of chemical targets in nuclear waste streams. However, methods to improve limits of detection as well as drop uncertainty in quantification are needed. Optimizing instrument specifications can achieve this, here this is demonstrated by comparing limits of detection for key analytes when using Raman systems with 671 nm, 532 nm, and 405 nm excitation wavelengths. Generally, limits of detection decease (allowing the measurement of lower salt concentrations) with decreasing wavelength. Similarly, data collection times and averaging were optimized. Finally, multiple chemometric modeling approaches were leveraged, including multiblock methods that combined data from all three Raman systems to simultaneously quantify targets with improved sensitivity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Microfluidic In-Situ Spectrophotometric Approaches to Tackle Actinides Analysis in Multiple Oxidation States

The study and development of present and future processes for the treatment/recycling of spent nuclear fuels require many steps, from design in the laboratory to setting up on an industrial scale. In all of these steps, analysis and instrumentation are key points. For scientific reasons (small-scale studies, control of phenomena, etc.) but also with regard to minimizing costs, risks, and waste, such developments are increasingly carried out on milli- or microfluidic devices. The logic is the same for the chemical analyses associated with their follow-up and interpretation. Due to this, over the last few years, opto–microfluidic analysis devices adapted to the monitoring of different processes (dissolution, liquid–liquid extraction, precipitation, etc.) have been increasingly designed and developed. In this work, we prove that photonic lab-on-a-chip (PhLoC) technology is fully suitable for all actinides concentration monitoring along the plutonium uranium refining extraction (plutonium, uranium, reduction, extraction, or Purex) process. Several PhLoC microfluidic platforms were specifically designed and used in different nuclear research and development (R&D) laboratories, to tackle actinides analysis in multiple oxidation states even in mixtures. The detection limits reached (tens of µmol·L −1 ) are fully compliant with on-line process monitoring, whereas a range of analyzable concentrations of three orders of magnitude can be covered with less than 150 µL of analyte. Finally, this work confirms the possibility and the potential of coupling Raman and ultraviolet–visible (UV–Vis) spectroscopies at the microfluidic scale, opening the perspective of measuring very complex mixtures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Raman Spectroscopy Coupled with Chemometric Analysis for Speciation and Quantitative Analysis of Aqueous Phosphoric Acid Systems

Complex chemical systems that exhibit varied and matrix-dependent speciation are notoriously difficult to monitor and characterize on-line and in real-time. Optical spectroscopy is an ideal tool for in situ characterization of chemical species that can enable quantification as well as species identification. Chemometric modeling, a multivariate method, has been successfully paired with optical spectroscopy to enable measurement of analyte concentrations even in complex solutions where univariate methods such as Beer’s law analysis fail. Here, Raman spectroscopy is used to quantify the concentration of phosphoric acid and its three deprotonated forms during a titration. In this system, univariate approaches would be difficult to apply due to multiple species being present simultaneously within the solution as pH is varied. Locally Weighted Regression (LWR) modeling was used to determine phosphate concentration from spectral signature. LWR results, in tandem with Multivariate Curve Resolution modeling, provide direct measurement of the concentration of each phosphate species using only the Raman signal. Furthermore, results are presented within the context of fundamental solution chemistry, including Pitzer equations to compensate for activity coefficients and non-idealities associated with high ionic strength systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enabling Microscale Processing: Combined Raman and Absorbance Spectroscopy for Microfluidic On-Line Monitoring

Microfluidics have many potential applications including characterization of chemical processes on a reduced scale, spanning the study of reaction kinetics using on-chip liquid–liquid extractions, sample pretreatment to simplify off-chip analysis, and for portable spectroscopic analyses. The use of in situ characterization of process streams from laboratory-scale and microscale experiments on the same chemical system can provide comprehensive understanding and in-depth analysis of any similarities or differences between process conditions at different scales. A well-characterized extraction of Nd(NO 3 ) 3 from an aqueous phase of varying NO 3– (aq) concentration with tributyl phosphate (TBP) in dodecane was the focus of this microscale study and was compared to an earlier laboratory-scale study utilizing counter current extraction equipment. Here, we verify that this same extraction process can be followed on the microscale using spectroscopic methods adapted for microfluidic measurement. Concentration of Nd (based on UV–vis) and nitrate (based on Raman) was chemometrically measured during the flow experiment, and resulting data were used to determine the distribution ratio for Nd. Extraction distributions measured on the microscale were compared favorably with those determined on the laboratory scale in the earlier study. Both micro-Raman and micro-UV–vis spectroscopy can be used to determine fundamental parameters with significantly reduced sample size as compared to traditional laboratory-scale approaches. This leads naturally to time, cost, and waste reductions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation-Induced Catalysis of Chemical Reactions

Nuclear energy is a process which achieves zero-carbon energy and heat generation that can provide a consistent electricity load to supply the grid when renewables are not available. However, on a cost per kilowatt-hour comparison, nuclear energy is more expensive than many of the renewable energy generation technologies such as wind and solar. In order to increase the economic viability of next generation nuclear reactors for energy production, generation of a secondary product such as a chemical feedstock would increase the economic viability of nuclear energy, particularly for new installations of next-generation nuclear reactors for power production. Currently, commercial nuclear reactors are primarily used for their heat to generate steam for electricity production. There is a large amount of unused energy in the form of photon and neutron radiation that could be exploited to drive chemical processes to produce feedstock materials as a secondary product of a nuclear plant. Chemical processing with radiation is not a new concept. In fact, gamma radiation is an excellent source of high energy photons to drive photochemical reactions. Dow chemical produced commercial quantities of ethyl bromide using gamma irradiation from a 60 Co source in the 1960s and 1970s because it was the most cost-effective means of production to meet the demand.5, 6 Due to the potential economic advantages, there is a new emphasis on studying feedstock production which can be enhanced by excess gamma and neutron radiation, particularly if the reaction could be monitored in real-time which is advantageous for process optimization. A model system of lignocellulose degradation under γ- radiation was chosen for this study while following the degradation products with Raman spectroscopy in real-time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗