Application Focused Schlieren to Nozzle Ejector Flowfields

The motivation of the testing was to reduce noise generated by eddy Mach wave emission via enhanced mixing in the jet plume. This was to be accomplished through the use of an ejector shroud, which would bring in cooler ambient fluid to mix with the hotter jet flow. In addition, the contour of the mixer, with its chutes and lobes, would accentuate the merging of the outer and inner flows. The objective of the focused schlieren work was to characterize the mixing performance inside of the ejector. Using flow visualization allowed this to be accomplished in a non-intrusive manner.

Mitchell, L. Kerry

Shield For Flexible Pipe

Cylindrical shield designed to fit around flexible pipe to protect nearby workers from injury and equipment from damage if pipe ruptures. Designed as pressure-relief device. Absorbs impact of debris ejected radially from broken flexible pipe. Also redirects flow of pressurized fluid escaping from broken pipe onto flow path allowing for relief of pressure while minimizing potential for harm.

Ponton, Michael K.

Water-Cooled Total-Temperature Probe

Water-cooled supersonic total-pressure, static-pressure, and total-temperature probes developed to study high-temperature jet plumes. Total-temperature probe tested up to 2,000 degrees F incorporates annular cooling system up to thermocouple lead. Lead extends into test chamber to sense temperature of supersonic external flow. Design novel and significant. Applicable in development of jet engines and in research on fast flows of hot gases.

Lagen, Nicholas T.

A wind tunnel application of large-field focusing schlieren

A large-field focusing schlieren apparatus was installed in the NASA Lewis Research Center 9 by 15 foot wind tunnel in an attempt to determine the density gradient flow field of a free jet issuing from a supersonic nozzle configuration. The nozzle exit geometry was designed to reduce acoustic emissions from the jet by enhancing plume mixing. Thus, the flow exhibited a complex three-dimensional structure which warranted utilizing the sharp focusing capability of this type of schlieren method. Design considerations concerning tunnel limitations, high-speed photography, and video tape recording are presented in the paper.

Ponton, Michael K.

The effects of temperature on supersonic jet noise emission

This paper examines the generation of sound produced by high temperature supersonic jets. In particular, the question of the importance of supersonic instability waves to noise emission is considered relative to the role of Kelvin-Helmholtz (K-H) instability waves. Here, these waves are taken to be synonymous with the Mach emission process. Jet total temperatures from 313 to 1534 K are investigated using an axisymmetric water cooled supersonic nozzle designed for Mach 2. The aerodynamic and acoustic results of this study indicate that the dominant noise contributors are the K-H waves over the entire temperature range. Good agreement between measured and numerically predicted plume properties are obtained and an elliptic nozzle is used to demonstrate reduction of the K-H waves.

Seiner, John M.

Water cooled static pressure probe

An improved static pressure probe containing a water cooling mechanism is disclosed. This probe has a hollow interior containing a central coolant tube and multiple individual pressure measurement tubes connected to holes placed on the exterior. Coolant from the central tube symmetrically immerses the interior of the probe, allowing it to sustain high temperature (in the region of 2500 F) supersonic jet flow indefinitely, while still recording accurate pressure data. The coolant exits the probe body by way of a reservoir attached to the aft of the probe. The pressure measurement tubes are joined to a single, larger manifold in the reservoir. This manifold is attached to a pressure transducer that records the average static pressure.

Lagen, Nicholas T.

Correction analysis for a supersonic water cooled total temperature probe tested to 1370 K

The authors address the thermal analysis of a water cooled supersonic total temperature probe tested in a Mach 2 flow, up to 1366 K total temperature. The goal of this experiment was the determination of high-temperature supersonic jet mean flow temperatures. An 8.99 cm exit diameter water cooled nozzle was used in the tests. It was designed for exit Mach 2 at 1366 K exit total temperature. Data along the jet centerline were obtained for total temperatures of 755 K, 1089 K, and 1366 K. The data from the total temperature probe were affected by the water coolant. The probe was tested through a range of temperatures between 755 K and 1366 K with and without the cooling system turned on. The results were used to develop a relationship between the indicated thermocouple bead temperature and the freestream total temperature. The analysis and calculated temperatures are presented.

Lagen, Nicholas T.

Evaluation of water cooled supersonic temperature and pressure probes for application to 2000 F flows

The development of water cooled supersonic probes used to study high temperature jet plumes is addressed. These probes are: total pressure, static pressure, and total temperature. The motivation for these experiments is the determination of high temperature supersonic jet mean flow properties. A 3.54 inch exit diameter water cooled nozzle was used in the tests. It is designed for exit Mach 2 at 2000 F exit total temperature. Tests were conducted using water cooled probes capable of operating in Mach 2 flow, up to 2000 F total temperature. Of the two designs tested, an annular cooling method was chosen as superior. Data at the jet exit planes, and along the jet centerline, were obtained for total temperatures of 900 F, 1500 F, and 2000 F, for each of the probes. The data obtained from the total and static pressure probes are consistent with prior low temperature results. However, the data obtained from the total temperature probe was affected by the water coolant. The total temperature probe was tested up to 2000 F with, and without, the cooling system turned on to better understand the heat transfer process at the thermocouple bead. The rate of heat transfer across the thermocouple bead was greater when the coolant was turned on than when the coolant was turned off. This accounted for the lower temperature measurement by the cooled probe. The velocity and Mach number at the exit plane and centerline locations were determined from the Rayleigh-Pitot tube formula.

Lagen, Nicholas T.