Search NASA⌕ Search

Engineering topics

Laggner, F. M.

Publications and source records attributed to Laggner, F. M..

Upgrade of the Lyman-alpha diagnostic system on DIII-D for main chamber edge neutral studies

The LLAMA (Lyman Alpha Measurement Apparatus) pinhole camera diagnostic had previously been deployed on DIII-D to measure radial profiles of the Lyman-α (Ly-α) deuterium neutral line brightness across the plasma boundary in the lower chamber to infer neutral deuterium density and ionization rate profiles. This system has recently been upgraded with a new diagnostic head, named ALPACA, that also encloses two pinhole cameras and duplicates the LLAMA views in the upper chamber. Similar to LLAMA, ALPACA provides two times 20 lines of sight, viewing the plasma edge on the inboard and outboard sides with a radial resolution of ~2.5 cm (FWHM) and an effective time resolution of ~1 ms that allows for the investigation of inter-ELM dynamics. The extended Ly-α system provides better coverage to study neutrals in experiments with various plasma shapes utilizing both the upper and lower divertors. Furthermore, post-campaign calibration of the LLAMA diagnostic has successfully been demonstrated for the first time. This was facilitated by various upgrades to the calibration set-up and detailed measurements of the emissivity distribution of the Ly-α calibration source using a pinhole collimator. It was found that the sensitivity of the inboard LLAMA pinhole camera was reduced by a factor of 2.0 ± 0.2 over the course of six months of plasma operation in 2021. In conclusion, the upgraded Ly-α system, equipped with improved absolute calibration, will provide key input for neutral fueling and pedestal particle transport studies and for 2D edge transport code validation on the DIII-D tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The role of isotope mass on neutral fueling and density pedestal structure in the DIII-D tokamak

Abstract Experimental measurements on DIII-D of hydrogen neutral penetration lengths ( λ n 0 ) on the high field side (HFS) are longer by a factor of 2 than for deuterium consistent with the thermal velocity ratio for neutrals at the same temperature ( v t h H / v t h D = 2 ) . This ratio is constant for both low and high pedestal electron density. At low pedestal density ( n e ∼ 4 × 10 19 m − 3 ) , the neutral penetration length is greater than the density pedestal width for both isotopes, and the additional 40% increase of neutral penetration in hydrogen widens the pedestal by the same amount. As the density pedestal height increases ( n e ∼ 6 × 10 19 m − 3 ) , the neutral penetration lengths drop below the density pedestal widths for both isotopes, and the increased penetration of hydrogen has no increased effect on the pedestal width compared to deuterium. Extrapolating to future reactor-relevant high electron density pedestals, the isotope-mass change in neutral fueling on the HFS from the deepest neutral penetration of hydrogen, to the shortest neutral penetration of tritium will be negligible (0.2–0.4 cm) in comparison to estimates of the density pedestal width (6–8.5 cm).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust identification of multiple-input single-output system response for efficient pickup noise removal from tokamak diagnostics

We report electromagnetic pickup noise in the tokamak environment imposes an imminent challenge for measuring weak diagnostic photocurrents in the nA range. The diagnostic signal can be contaminated by an unknown mixture of crosstalk signals from coils powered by currents in the kA range. To address this issue, an algorithm for robust identification of linear multi-input single-output (MISO) systems has been developed. The MISO model describes the dynamic relationship between measured signals from power sources and observed signals in the diagnostic and allows for a precise subtraction of the noise component. The proposed method was tested on experimental diagnostic data from the DIII-D tokamak, and it has reduced noise by up to 20 dB in the 1–20 kHz range.

47 OTHER INSTRUMENTATION↗

Details of the neutral energy distribution and ionization source using spectrally resolved Balmer-alpha measurements on DIII-D

Spectrally resolved passive Balmer- α (D- α, H- α) measurements from the DIII-D 16 channel edge main-ion charge exchange recombination system confirm the presence of higher energy neutrals (“thermal” neutrals) in addition to the cold neutrals that recycle off the walls in the edge region of DIII-D plasmas. Charge exchange between thermal ions and edge neutrals transfers energy and momentum between the populations giving rise to thermal neutrals with energies approximating the ions in the pedestal region. Multiple charge exchange events in succession allow an electron to effectively take a random walk, transferring from ion to ion, providing a pathway of increasing energy and velocity, permitting a neutral to get deeper into the plasma before a final ionization event that contributes to the ion and electron particle fueling. Spectrally resolved measurements provide information about the density and velocity distribution of these neutrals, which has been historically valuable for validating Monte Carlo neutral models, which include the multi stage charge exchange dynamics. Here, in this study, a multi-channel set of such measurements is used to specifically isolate the details of the thermal neutrals that are responsible for fueling inside the pedestal top. Being able to separate the thermal from the cold emission overcomes several challenges associated with optical filter-based neutral density measurements. The neutral dynamics, deeper fueling by the thermal neutrals, and spectral measurement are modeled with the FIDASIM Monte Carlo collisional radiative code, which also produces synthetic spectra with a shape that is in close agreement with the measurements. By scaling the number of neutrals in the simulation to match the intensity of the thermal emission, we show it is possible to obtain local neutral densities and ionization source rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Local measurements of the pedestal magnetic field profile throughout the ELM cycle on DIII-D

We report new high speed localized measurements of the pedestal magnetic field during the edge localized mode (ELM) cycle of a DIII-D High confinement mode (H-mode) discharge indicate a temporally and spatial complex redistribution of the edge current density profile, $j_{edge}$. The measurement technique extracts the magnetic field magnitude, $\textit{B}$, via the spectral separation of Stark-split neutral beam radiation in the pedestal. Single spatial channel measurements from a novel spatial heterodyne spectrometer are validated in discharges with core current profile changes. The technique measures Stark-splitting changes that imply $\textit{B}$ changes as small as 1 mT with high time resolution (50 μs). At normalized poloidal flux $ψ_n$ = 1.0, $\textit{B}$ appears saturated in the inter-ELM period and then rapidly decreases in <200 μs by ~1%, before edge recycling emission begins to increase. Radially inboard of $j_{edge}$, $\textit{B}$ increases at the ELM crash. The behavior is consistent with a rapid collapse of $j_{edge}$ at the ELM crash and subsequent pedestal recovery. In some discharges, at $ψ_n$ < 0.96, changes in $\textit{B}$ are observed throughout the ELM cycle. In others, $\textit{B}$ recovers and is relatively stable until a few ms leading up to the next crash. Measurements of $\textit{B}$ during the H-mode transition show a large increase at $ψ_n$ = 1 with little change at $ψ_n$ = 0.9, consistent with the formation of the edge bootstrap current density peak. The $ψ_n$ = 0.9 spectrum is complicated by predicted changes to the Stark component intensities with density at the L–H transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigation of plasma–wall interactions with low-Z powders in DIII-D high confinement plasmas

Experiments with low-Z powder injection in DIII-D high confinement discharges demonstrated increased divertor dissipation and detachment while maintaining good core energy confinement. Lithium (Li), boron (B), and boron nitride (BN) powders were injected in H-mode plasmas (I p = 1 MA, B t = 2 T, P NB = 6 MW, < n e > = 3.6–5.0 · 10 19 m –3 ) into the upper small-angle slot divertor for 2 s intervals at constant rates of 3–204 mg s –1 . The multi-species BN powders at a rate of 54 mg s –1 showed the most substantial increase in divertor neutral compression by more than an order of magnitude and lasting detachment with minor degradation of the stored magnetic energy W mhd by 5%. Rates of 204 mg s –1 of boron nitride powder further reduce edge localized mode-fluxes on the divertor but also cause a drop in confinement performance by 24% due to the onset of an n = 2 tearing mode. The application of powders also showed a substantial improvement of wall conditions manifesting in reduced wall fueling source and intrinsic carbon and oxygen content in response to the cumulative injection of non-recycling materials. Furthermore, the results suggest that low-Z powder injection, including mixed element compounds, is a promising new core-edge compatible technique that simultaneously enables divertor detachment and improves wall conditions during high confinement operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion thermal transport in the H-mode edge transport barrier on DIII-D

The power balance ion heat flux in the pedestal region on DIII-D increases and becomes increasingly anomalous (above conventional neoclassical) in experiments with higher temperature and lower density pedestals where the ion collisionality ($v^*_i$) is lowered toward values expected on ITER. Direct measurements of the main-ion temperature are shown to be essential on DIII-D when calculating the ion heat flux due to differences between the temperature of $D^+$ and the more commonly measured $C^{6+}$ impurity ions approaching the separatrix. Neoclassical transport calculations from NEO and non-linear gyrokinetic calculations using CGYRO are consistent with these observations and show that while neoclassical transport plays an important role, the turbulent ion heat flux due to ion scale electrostatic turbulence is significant and can contribute similar or larger ion heat fluxes at lower collisionality. Beam emission spectroscopy and Doppler backscattering measurements in the steep gradient region of the H-mode pedestal reveal increased broadband, long-wavelength ion scale fluctuations for the low $v^*_i$ discharges at the radius where the non-linear CGYRO simulations were run. Taken together, increased fluctuations, power balance calculations, and gyrokinetic simulations show that the above neoclassical ion heat fluxes, including the increases at lower $v^*_i$, are likely due to weakly suppressed ion scale electrostatic turbulence. These new results are based on world first inferred ion and electron heat fluxes in the pedestal region of deuterium plasmas using direct measurements of the deuterium temperature for power balance across ion collisionalities covering an order of magnitude from high $v^*_i$ values of 1.3 down to ITER relevant $v^*_i$ ~0.1.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Initial operation and data processing on a system for real-time evaluation of Thomson scattering signals on the Large Helical Device

A scalable system for real-time analysis of electron temperature and density based on signals from the Thomson scattering diagnostic, initially developed for and installed on the NSTX-U experiment, was recently adapted for the Large Helical Device and operated for the first time during plasma discharges. During its initial operation run, it routinely recorded and processed signals for four spatial points at the laser repetition rate of 30 Hz, well within the system’s rated capability for 60 Hz. We present examples of data collected from this initial run and describe subsequent adaptations to the analysis code to improve the fidelity of the temperature calculations.

47 OTHER INSTRUMENTATION↗

High fusion performance in Super H-mode experiments on Alcator C-Mod and DIII-D

The ‘Super H-Mode’ regime is predicted to enable pedestal height and fusion performance substantially higher than standard H-Mode operation. This regime exists due to a bifurcation of the pedestal pressure, as a function of density, that is predicted by the EPED model to occur in strongly shaped plasmas above a critical pedestal density. Experiments on Alcator C-Mod and DIII-D have achieved access to the Super H-Mode (and Near Super H) regime, and obtained very high pedestal pressure, including the highest achieved on a tokamak (pped ~ 80 kPa) in C-Mod experiments operating near the ITER magnetic field. DIII-D Super H experiments have demonstrated strong performance, including the highest stored energy in the present configuration of DIII-D (W ~ 2.2–3.2 MJ), while utilizing only about half of the available heating power (Pheat ~ 7–12 MW). These DIII-D experiments have obtained the highest value of peak fusion gain, QDT,equiv ~ 0.5, achieved on a medium scale (R < 2 m) tokamak. Sustained high performance operation (βN ~ 2.9, H98 ~ 1.6) has been achieved utilizing n = 3 magnetic perturbations for density and impurity control. Pedestal and global confinement has been maintained in the presence of deuterium and nitrogen gas puffing, which enables a more radiative divertor condition. A pair of simple performance metrics is developed to assess and compare regimes. Super H-Mode access is predicted for ITER and expected, based on both theoretical prediction and observed normalized performance, to allow ITER to achieve its goals (Q = 10) at Ip < 15 MA, and to potentially enable more compact, cost effective pilot plant and reactor designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 1D Lyman-alpha profile camera for plasma edge neutral studies on the DIII-D tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-α) emission from hydrogen isotopes, which can be used to infer neutral density and ionization rate profiles. The system is composed of two cameras, each providing a toroidal fan of 20 lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras’ views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of ~2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-α reflective mirror, narrow-band Ly-α transmission filter, and a 20 channel AXUV photodetector. The combined mirror and transmission filter have a FWHM of 5 nm, centered near the Ly-α wavelength of 121.6nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-α brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling, and radial particle transport.

Ionization Rate↗

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A 1D Lyman-alpha Profile Camera for Plasma Edge Neutral Studies on the DIII-D Tokamak

A one dimensional, absolutely calibrated pinhole camera system was installed on the DIII-D tokamak to measure edge Lyman-alpha (Ly-a) emission from hydrogenic isotopes which can be used to infer neutral density and ionization rate proles. The system is composed of two cameras, each providing a toroidal fan of twenty lines of sight, viewing the plasma edge on the inboard and outboard side of DIII-D. The cameras' views lie in a horizontal plane 77 cm below the midplane. At its tangency radius, each channel provides a radial resolution of approximately 2 cm full width at half maximum (FWHM) with a total coverage of 22 cm. Each camera consists of a rectangular pinhole, Ly-a reflective mirror, narrow-band Ly-a transmission fiter, and a 20 channel AXUV photodetector. The combined mirror and transmission fiter have a FWHM of 5 nm, centered near the Ly-a wavelength of 121.6 nm and is capable of rejecting significant, parasitic carbon-III (C-III) emission from intrinsic plasma impurities. To provide a high spatial resolution measurement in a compact footprint, the camera utilizes advanced engineering and manufacturing techniques including 3D printing, high stability mirror mounts, and a novel alignment procedure. Absolutely calibrated, spatially resolved Ly-a brightness measurements utilize a bright, isolated line with low parasitic surface reflections and enable quantitative comparison to modeling to study divertor neutral leakage, main chamber fueling and radial particle transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Review: Turbulence dynamics during the pedestal evolution between edge localized modes in magnetic fusion devices

Fusion performance has been shown to be related to the H-mode pedestal structure. The pedestal is associated with steep gradients that are the source of free energy for microinstabilities. A variety of instabilities have been shown to co-exist in the pedestal. This paper reviews the experimentally observed signatures of instabilities during the pedestal parameters' evolutions, with a focus on turbulence observations, made in between edge localized modes (ELMs), in multiple tokamaks. ELMs are cyclic events associated with bursty relaxations of the pedestal. The multiple machine results point to very similar pedestal localized modes suggesting the existence of a unifying mechanism governing the modes' onset and dynamics. Modeling efforts to identify the generation mechanism of these instabilities are introduced. Several remaining challenges include the study of the instability saturation mechanisms and impact on the pedestal structure formation. Finally, potential future research avenues will require multiscale-non-linear-gyrokinetic analyses to study the non-linear interaction between these instabilities, and which pedestal conditions facilitate such non-linear interactions, as well as the relationship with the formation of the pedestal through transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗