Search NASA⌕ Search

Engineering topics

Laminack, Alex

Publications and source records attributed to Laminack, Alex.

First β -delayed neutron spectroscopy of 24 O

The β decay of 24 O was investigated at NSCL/MSU using a combination of neutron and γ-ray spectroscopy. For the first time, the β-delayed neutron energy spectrum of 24 O was measured, revealing three intensely populated, isolated neutron-unbound states in 24 F. This allowed for the extraction of the decay strength in 24 F up to 6.2 MeV. A comprehensive comparison of the experimental results with various nuclear theories, ranging from the empirical shell model to the most advanced ab initio calculations, was conducted. While most theoretical predictions align with the experimental data for low-lying states, discrepancies arise at higher excitation energies. Finally, in the transition from 24 O to 24 F, shell model calculations using the empirical USDB interaction predicted the structure of both nuclei without invoking the need for a stronger proton-neutron tensor force, which was postulated for the neighboring isotone 25 F.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress Toward Gamma-Ray Imaging for Automated Holdup Measurement in Gloveboxes

Shielded gloveboxes are currently being constructed to facilitate dilution and disposal of many tons of excess plutonium oxide. Measuring holdup in these gloveboxes is expected to be challenging because of the limited available lines of sight through the glovebox shielding. A system of gamma-ray imagers is being developed to provide localization and quantification for holdup. The system will be mounted above the glovebox, where there is minimal shielding. Multiple imagers with overlapping coded-aperture fields of view are employed to enable three-dimensional reconstruction. Compton reconstruction is also available to localize sources outside the coded-aperture field of view. Improved uncertainties with respect to current techniques are expected by virtue of the fixed installation, spectroscopic performance of the detectors, and iterative image reconstruction techniques. Measurement campaigns have been undertaken at an active glovebox at Savannah River Site to test the gamma-ray imaging system in an operational environment, providing a simple test of a single imager that mimics the geometry of the installation proposed for future shielded gloveboxes. Data taken during quiescent periods in the glovebox were used to measure the buildup of material on an outlet filter and record a trend over time. Calibration data was taken with known sources to simplify analysis and provide a reliable assay of the filter. Resulting images make it possible to isolate the filter from other sources and recognize compromised data. This paper will present details of the measurement and analysis methods.

Schmitt, Kyle↗

Multimodal Data Fusion with 3D Gamma-Ray Imaging for Safeguards (2023 Annual Report)

Improve the quantitative results obtained from 3D gamma-ray imagers for use in safeguards inspections. In FY23 the work focused on continuing to improve the numerical results obtained with gamma-ray imagers and explore approaches to project such data onto 3D structures mapped with Self Localization and Mapping (SLAM) hardware and software.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

3D Source Reconstruction Using Coded Aperture Gamma-Ray Imaging

Recent measurements with coded-aperture imagers demonstrate material mass determination in a holdup setting to an accuracy within a few percent. This capability is of particular interest to the Surplus Plutonium Disposition (SPD) project, which aims to dilute and dispose of surplus plutonium oxide. Gamma-ray imagers can be used to determine holdup without interrupting normal operations. In this work, we examine techniques for 3D source localization and mass determination using gamma-ray imagers. Coded-aperture imagers provide excellent source localization within the 2D image plane; however, multiple imagers operating in tandem are necessary to identify source location in 3D space. A Maximum Likelihood Expectation-Maximization (MLEM) method for fitting detector mappings is a powerful tool for accomplishing this task. MLEM allows 3D source localization to be simultaneously constrained using multiple gamma-ray imagers by constructing the basis for the MLEM fit using detector mappings from different detector locations stitched together. Each of these basis points represents a singular response from a source in 3D space and is generated using Monte Carlo simulations of sources placed individually at different locations throughout the imager’s field of view. Additionally, implementing knowledge of the physical equipment in the simulations of the glovebox used for the SPD project incorporates attenuation effects that are needed to calculate material holdup.

Laminack, Alex↗

NDA Tech: Multimodal Data Fusion with 3D Gamma-Ray Imaging for Safeguards

The ultimate project goal is to improve quantitative results obtained by the IAEA with the H420 gamma ray imager. Distribution to the IAEA will be through incorporation of project results into the software provided with the device by our commercial partner, H3D, Inc. Toward achieving that goal, we have started discussions with H3D to identify the requisite software components and how they will mesh with their own internally developed contextual data systems and other extant software components. We have identified the coded-aperture response data cube as a key structure. Discussions on contextual imaging were informative but somewhat inconclusive as the project lead on contextual data (LBNL) has not been available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of a System of Gamma Imagers for Measuring Plutonium Holdup

The Surplus Plutonium Disposition (SPD) project is an effort to dilute and dispose of many tonsof weapons grade plutonium. This work will take place in a shielded glovebox to protect workers fromradiological dose. Accurate measurements of the holdup, or material left behind, in the gloveboxes is im-portant for Nuclear Material Control and Accountancy, worker dose minimization, criticality safety, andprocess monitoring. Shielding around the gloveboxes presents an obstacle for the traditional GeneralizedGamma Holdup (GGH) method. The uncertainties associated with that method, at around 28%, arealso detrimental since the amount of holdup must be kept below an established limit with a high level ofconfidence.Passive gamma-ray imaging provides a more complete depiction of the distribution of radioactivematerials. Recent refinement of the method has demonstrated that quantitative information can beextracted from the images with a well-characterized system. A permanently installed system of gamma-ray imagers is currently being developed to measure plutonium holdup in the SPD gloveboxes. Thispaper will report on progress with the development of this system.This application requires that the features of current commercially available instruments from H3Dand PHDS, optimized for measurement performance in a mobile application, be translated into theconstraints of the operational environment with fixed installations. The interaction between facilityconstraints and measurement capabilities will be addressed.A series of measurements with plutonium sources in a mocked-up glovebox geometry with imagersmounted above the ceiling of the glovebox have been taken. Imager performance with respect to angularresolution, minimum measurement time for quantification, and signal-to-noise ratio with a multitudeof sources will be evaluated for those measurements. A series of prototypes of user interfaces will bepresented for display of the data to its various consumers for the purposes of Nuclear Material Controland Accountancy, worker dose minimization, criticality safety, and process monitoring.

Schmitt, Kyle↗

Performance Evaluation of the Starfire nGen-350 DD Neutron Generator for use with the Fast Neutron Coincidence Collar

The Starfire Industries nGen-350 DD neutron generator has been developed for use with the Fast Neutron Coincidence Collar (FNCL). The generator was adapted from the nGen-310 model generator by Starfire to accommodate an International Atomic Energy Agency (IAEA) request to incorporate a neutron yield stabilization mechanism. An nGen-350 generator was obtained by Oak Ridge National Laboratory (ORNL) for evaluation as a potential neutron interrogation source replacement for Am(Li) in the FNCL. This report provides a summary of the performance of the nGen-350.

43 PARTICLE ACCELERATORS↗