Remote sensing of atmospheric oxygen from a sounding rocket

This paper describes a rocket experiment to investigate mechanisms governing the interactions between two of the fundamental components of the solar-terrestrial system: the solar ionizing radiation and the earth's upper atmosphere. The aim is to characterize the extreme ultraviolet (EUV) emissions resulting from these interactions in terms of physical parameters so that EUV remote sensing can be gainfully employed as a quantitative diagnostic of the terrestrial atmosphere and plasma environment. The payload consists of a high-resolution (about 0.5 A) spectrometer to measure the EUV emissions (980-1360 A) of the earth's dayglow, a moderate resolution (about 15 A) EUV spectrometer (250-1450 A) to measure the solar irradiation responsible for the photoelectron production, and a hydrogen Lyman Alpha photometer to monitor the solar irradiance and geocoronal emissions.

Chakrabarti, S.

Construction and evaluation of an imaging focussed-mesh electron multiplier for space instrumentation

A focused-mesh electron multiplier (FMEM) has been combined with a wedge and strip position-sensitive anode to create a novel detector that is considered likely to have a number of applications in space astronomy and laboratory image sensing. Results from the first application of a wedge and strip anode to an FMEM are presented including spatial resolution, spatial linearity, background rate, and pulse risetime. The converted multiplier retains the attributes of an FMEM that made it attractive in the first place, such as low background, high speed, and high dynamic range.

Vallerga, J.

Extreme ultraviolet quantum efficiency of opaque alkali halide photocathodes on microchannel plates

Comprehensive measurements are presented for the quantum detection efficiency (QDE) of the microchannel plate materials CsI, KBr, KCl, and MgF2, over the 44-1800 A wavelength range. QDEs in excess of 40 percent are achieved by several materials in specific wavelength regions of the EUV. Structure is noted in the wavelength dependence of the QDE that is directly related to the valence-band/conduction-band gap energy and the onset of atomic-like resonant transitions. A simple photocathode model allows interpretation of these features, together with the QDE efficiency variation, as a function of illumination angle.

Siegmund, O. H. W.

Charge coupled devices vs. microchannel plates in the extreme and far ultraviolet - A comparison based on the latest laboratory measurements

While microchannel plates (MCPs) have been established as imaging photon counters in the EUV and FUV for some years, CCDs are associated with low light level sensing at visible and near-IR wavelengths. Attention is presently given to recent proposals for CCDs' use as EUV and FUV detectors with quantum efficiencies sometimes exceeding those of MCPs; quantum resolution, format size, dynamic range, and long-term stability are also used as bases of comparison, for the cases of both space-based astronomical and spectroscopic applications.

Vallerga, J.

Delay line anodes for microchannel-plate spectrometers

A photon-counting readout system for microchannel-plate spectrometers is described that uses a delay line and timing circuit for the wavelength coordinate and a wedge-wedge charge division system for the orthogonal spatial coordinate. A novel zigzag layout allows these two anode patterns to coexist on a common planar substrate and share the charge from each photoevent, thereby simultaneously localizing the photon in each of its two dimensions. Unlike wedge-and-strip or resistive anode encoders, the delay line offers a spatial resolution that is relatively independent of the format length. Unlike discrete anode systems, the delay line readout system's complexity is also independent of the field of view size. These facts make the delay line readout system advantageous in large format detectors. A testbed detector having a delay line propagation speed of 2.2 mm/ns and a time resolution of 33 ps FWHM has been assembled. Ultraviolet testing shows a Gaussian event distribution having a 70-micron FWHM width; the readout system blur contribution is less than 50-micron FWHM.

Lampton, M.

Ultraviolet quantum detection efficiency of potassium bromide as an opaque photocathode applied to microchannel plates

The quantum detection efficiency (QDE) of potassium bromide as a photocathode applied directly to the surface of a microchannel plate over the 250-1600 A wavelength range has been measured. The contributions of the photocathode material in the channels and on the interchannel web to the QDE have been determined. Two broad peaks in the QDE centered at about 450 and about 1050 A are apparent, the former with about 50 percent peak QDE and the latter with about 40 percent peak QDE. The photoelectric threshold is observed at about 1600 A, and there is a narrow QDE minimum at about 750 A which correlates with 2X the band gap energy for KBr. The angular variation of the QDE from 0 to 40 deg to the channnel axis has also been examined. The stability of Kbr with time is shown to be good with no significant degradation of QDE at wavelengths below 1216 A over a 15-day period in air.

Siegmund, Oswald H. W.

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.

Operational characteristics of Wedge and Strip image readout systems

Application of the Wedge and Strip readout system in microchannel plate detectors for the Extreme Ultraviolet Explorer and FAUST space astronomy programs is discussed. Anode designs with high resolution (greater than 600 x 600 pixels) in imaging and spectroscopy applications have been developed. Extension of these designs to larger formats (100 mm) with higher resolution (3000 x 3000 pixels) are considered. It is shown that the resolution and imaging are highly stable, and that the flat field performance is essentially limited by photon statistics. Very high speed event response has also been achieved with output pulses having durations of less than 10 nanoseconds.

Siegmund, O. H. W.

A position sensitive microchannel photomultiplier for ultraviolet space astronomy

The 25-mm microchannel-plate, position-sensitive UV astronomy photomultiplier tube presented is intended for the EOM-1 Spacelab Mission's FAUST payload and conducts wide-field imaging surveys in the VUV over the 1400-1800-A range. The sealed detector encompasses a CsI photocathode deposited on the inner surface of a MgF2 window, a stack of microchannel plates, and a wedge-and-strip two-dimensional position-sensing anode. Since the wedge-and-strip principle requires only three anode signals, flight electronics can be reduced to three charge amplifiers and three analog-to-digital converters.

Lampton, M.

Application of wedge and strip image readout systems to detectors for astronomy

Microchannel plate (MCP) detector systems that use wedge and strip anodes for imaging radiation in the range 50 A to 8000 A are described. Test data, obtained from the calibration of the Extreme Ultraviolet Explorer Satellite detectors and the ARIA EUV aeronomy sensor is presented. The long-term performance characteristics of Z-stack microchannel plates are investigated and it is shown that stable operation is achieved after an initial settling period. Conventional and new anode designs and their potential for increasing the position resolution are discussed. Position resolution of better than 80 microns FWHM has been attained for 50 mm devices, and this is shown to be essentially independent of event location. Image nonlinearity of less than 0.3 percent has been achieved with stability to better than 0.1 percent. Differential nonlinearity of less than 1 percent and stability to better than 1 percent have been obtained. Measurements of the quantum efficiency of a CsI photocathode on an MCP are presented, demonstrating efficiencies as high as 47 percent.

Siegmund, O. H. W.

Astronomical observations with the FAUST telescope

The far-ultraviolet space telescope (FAUST) was flown on Spacelab 1 to provide wide-field imaging in the wavelength range 1300 to 1800 angstroms.Most of the developed film showed high levels of background exposure. Frames with a lower background included exposures of the Cygnus Loop supernova remnant and an exposure in the direction of the galaxy cluster Abell 2634. Several exposures will be used in a search for hot white dwarf stars.

Bixler, J.

A versatile ground data display system for Spacelab experiments

A microprocessor-based data capture and display system suited to the needs of many Spacelab experimenters is described. Although developed specifically for the needs of the FAUST UV astronomy telescope, several features of the system may make it attractive to other groups who need to interact with their Spacelab data in real or near-real time. The display system captures data from the serial data stream originating in the Spacelab experiment computer input/output (ECIO) data channel, and can reformat and display several hundred variables per second in real time. The system offers a combination of CRT display and analog paper strip-chart output. A facility is also provided for simultaneously creating floppy-disk records of short segments of data according to prearranged criteria, to allow detailed examination of critical events in the operation of the experiment. The simplicity, economy, reliability, and flexibility of the display system suggest its use for monitoring a variety of low- and medium-data-rate Spacelab experiments.

Werthimer, D.

The nautre of dwarf novae and related systems

The high energy emissions from cataclysmic variables (interacting binary systems containing an accreting white dwarf) and the relationship of the high energy emission of these stars to their optical properties were investigated. The relationship of the cataclysmic binaries to the strong X-ray emitting binaries that contain a neutron star as the accreting star was examined. A soft X-ray survey of cataclysmic variable stars was carried out. Approximately 75% of all the sources observed were detected in short (2000 sec) observations. Relationships between the X-ray and optical luminosity and the dependence of this quantity on the subclass of the variable were investigated and constraints on the nature of these systems were provided.

Lampton, M.

The Berkeley parasitic SETI program

Parasitic programs for the Search for Extraterrestrial Intelligence (SETI), carried out concurrently with conventional radio astronomical observing programs, can be an attractive and cost-effective means of exploring the large multidimensional search space intrinsic to this effort. A microprocessor-based automated SETI acquisition system is described which searches for, and records, spectra of narrowband signals in the IF band of an observatory receiver. Data taken with this system over 35 days at the Hat Creek Radio Observatory at 1612 MHz are discussed. Out of approximately 100,000 spectra processed during this period, 4000 were identified by the system as containing narrowband signals and were recorded. Subsequent analysis indicates that over 3900 of these are due to local RF contamination. The remainder are undergoing further investigation.

Bowyer, S.

The soft X-ray spectrum of Sirius B - Evidence for the photospheric hypothesis

The soft X-ray spectrum of Sirius obtained by the HEAO 1 A-2 experiment is used to investigate the origin of the X-radiation from that system. It is shown that, if the emission is coronal, then the coronal temperature must be less than 150,000 K, and the coronal luminosity must be greater than 10 to the 33rd ergs/s. Such a corona conflicts severely with EUV observations and is physically untenable. White dwarf atmosphere models are fitted to the spectrum and it is shown that a photospheric temperature of 28,000 K is much more consistent with the data. The relative consistency of the soft X-ray, EUV, and UV observations of Sirius B is discussed and it is concluded that the evidence favors the white dwarf photosphere as the origin of the soft X-rays.

Martin, C.