Sum-of-Fractions Methodology for Actinides in Water- and Polyethylene-Moderated and -Reflected Systems

Sum-of-fractions is a method intended to make sure a subcritical margin for aqueous solutions and slurries of fissionable isotopes exists. The method indicates that a system is subcritical if the sum of the ratios of the mass of each isotope (in a mixture) to its individual minimum subcritical mass limit is less than or equal to one. Historically, the basis of the sum-of-fractions has been derived from allowances given in the American National Standards Institute (ANSI)/ American Nuclear Society (ANS)-8.15-1981. However, the allowance was removed in ANSI/ANS-8.15-2014 due to a lack of technical basis. A methodology was developed to assess the validity of using the sum-of-fractions for water- or polyethylene-moderated systems for the following nuclides: 232 U, 233 U, 234 U, 235 U, 237 Np, 236 Pu, 238 Pu, 239 Pu, 240 Pu, 241 Pu, 242 Pu, 241 Am, 242 m Am, 243 Am, 242 Cm, 243 Cm, 244 Cm, 245 Cm, 246 Cm, 247 Cm, 249 Cf, and 251 Cf. The methodology uses available benchmark data for mixtures of 233 U, 235 U, and 239 Pu to establish the calculational margin, and a mass limit reduction to establish the margin of subcriticality. Water- or polyethylene-moderated and -reflected mixtures containing the nuclides are evaluated with the code system, SCALE 6.2.4. Including the calculational margin, subcritical mass limits for each nuclide were computed for optimally water- or polyethylene-moderated and fully reflected systems. These masses were used to create nuclide mixtures in which the sum of the mass to subcritical mass limit ratios is one. The various nuclide mixtures were modeled over a range of moderation and demonstrate the keff does not exceed the calculational margin. For additional assurance of subcriticality, a significant mass reduction is applied to each computed minimum critical mass of the nuclides without adequate benchmark data consistent with the method in ANSI/ANS-8.15-2014.

07 ISOTOPE AND RADIATION SOURCES↗

Impact of Thermal Scattering Law on Similarity Assessment in Light-Water or Polyethylene-Moderated Systems

A collaborative effort between Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) is underway to provide a technical basis and methodology for the criticality safety community to use the sum of fractions (SoF) method for generating limits for mixtures of “selected actinide nuclides” included in the ANSI/ANS 8.15 standard. The PNNL scope in this project is to define a range of mixtures of 233 U, 235 U, and 239 Pu moderated with either light water or polyethylene and to examine the critical masses for these mixtures. The ORNL scope is primarily to provide validation support for these studies. More complete discussion of the project and its validation aspects will be presented at the upcoming International Conference on Nuclear Criticality Safety (ICNC) this Fall in Sendai, Japan. Clear differences in benchmark similarity to application systems as assessed by the integral parameter ck are noted in the validation studies performed as part of this project as a function of moderator. The c k value is a correlation coefficient that represents that amount of shared uncertainty in k eff due to cross sections between two systems. Individual nuclide-reaction contributions between the two systems can be simply summed to arrive at the total c k value. Specifically, the c k values for light-water–moderated solution experiments are higher for a water-moderated application than for a polyethylene-moderated application. This result is neither totally unexpected nor surprising, but the magnitude of the difference was difficult to anticipate. The TSUNAMI sequence, in the SCALE 6.2.4 code package developed by ORNL, was used to generate eigenvalues and reactivity effects with perturbation-theory based approach through sensitivity coefficients for all nuclides in the system with all reactions and energy groups. The TSUNAMI-Indices and Parameters (IP) sequence then uses the sensitivity data generated through TSUNAMI to generate relational parameters (i.e., c k ) to determine the degree of similarity between systems. One detail of the SCALE material and data implementation must be discussed at this point. Several thermal scattering laws (TSLs) are available for 1 H. SCALE uses a different nuclide ID number for each TSL; essentially, each version of 1 H is treated as a unique nuclide. For example, 1 H bound in water ( 1 H-H2O) is assigned the nuclide ID 1001, whereas 1 H bound in polyethylene (h-poly) is assigned the nuclide ID 9001001. The same cross section data are used for all reactions in 1 H, regardless of TSL, except for scattering below the TSL cutoff energy. TSUNAMI-IP treats different nuclide IDs as different nuclides; thus, no uncertainty is shared between 1 H-H2O and h-poly, despite much of the same data, including covariance data, being used for both nuclides. This presents a question: how much of the difference in assessed similarity between water- and polyethylene-moderated systems is due to the moderators, and how much is caused by the treatment of 1 H-H2O and h poly with cross section and covariance data. The extended edits generated by TSUANMI-IP allow for an investigation of this issue specifically, as well as a demonstration of the general techniques available within TSUNAMI to understand the results of the similarity assessment. This paper presents and analyzes the similarity assessment of both water- and polyethylene-moderated systems for a single benchmark: PST-002-001.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Oak Ridge Subcritical Assembly Final Design and Current Progress [Slides]

This presentation shows how ORSA design has moved from conceptual to implementable. Additionally, that the ORSA hands-on experiments will remain subcritical under normal and credible abnormal conditions it is fully assembled k eff = 0.95024 ± 0.0003 and USL = 0.9763. This presentation finds locations will have minimal security and safety basis impact. Available options can meet security criteria for ORSA material and Options will have less mass than the ANS-8.1 single parameter limit for 235 U either by segregation or functioning as its own facility. Further, Locations are feasible for a diversity of students and the implementation of ORSA will improve upon NCSP T&E’s vision to remain adaptable and responsive.