Search NASA⌕ Search

Engineering topics

Lang, M.

Publications and source records attributed to Lang, M..

26 records · Page 2

Stability of fluorite-type La 2 Ce 2 O 7 under extreme conditions

Here, the structural stability of fluorite-type La 2 Ce 2 O 7 was studied at pressure up to ~40 GPa and under hydrothermal conditions (~1 GPa, 350 °C), respectively, using synchrotron x-ray diffraction (XRD) and Raman scattering measurements. XRD measurements indicated that fluorite-type La 2 Ce 2 O 7 is not stable at pressures greater than 22.6 GPa and slowly transforms to a high-pressure phase. The high-pressure phase is not stable and changes back to the fluorite-type structure when pressure is released. The La 2 Ce 2 O 7 fluorite is also not stable under hydrothermal conditions and begins to react with water at 200~250 °C. Both Raman and XRD results suggest that lanthanum hydroxide La(OH) 3 and La 3+ -doped CeO 2 fluorite are the dominant products after hydrothermal treatment.

36 MATERIALS SCIENCE↗

Planning for Pre-Exascale Platform Environment (Fiscal Year 2015 Level 2 Milestone 5216)

This Plan for ASC Pre-Exascale Platform Environments document constitutes the deliverable for the fiscal year 2015 (FY15) Advanced Simulation and Computing (ASC) Program Level 2 milestone Planning for Pre-Exascale Platform Environment. It acknowledges and quantifies challenges and recognized gaps for moving the ASC Program towards effective use of exascale platforms and recommends strategies to address these gaps. This document also presents an update to the concerns, strategies, and plans presented in the FY08 predecessor document that dealt with the upcoming (at the time) petascale high performance computing (HPC) platforms. With the looming push towards exascale systems, a review of the earlier document was appropriate in light of the myriad architectural choices currently under consideration. The ASC Program believes the platforms to be fielded in the 2020s will be fundamentally different systems that stress ASC’s ability to modify codes to take full advantage of new or unique features. In addition, the scale of components will increase the difficulty of maintaining an errorfree system, thus driving new approaches to resilience and error detection/correction. The code revamps of the past, from serial- to vector-centric code to distributed memory to threaded implementations, will be revisited as codes adapt to a new message passing interface (MPI) plus “x” or more advanced and dynamic programming models based on architectural specifics. Development efforts are already underway in some cases, and more difficult or uncertain aspects of the new architectures will require research and analysis that may inform future directions for program choices. In addition, the potential diversity of system architectures may require parallel if not duplicative efforts to analyze and modify environments, codes, subsystems, libraries, debugging tools, and performance analysis techniques as well as exploring new monitoring methodologies. It is difficult if not impossible to selectively eliminate some of these activities until more information is available through simulations of potential architectures, analysis of systems designs, and informed study of commodity technologies that will be the constituent parts of future platforms.

97 MATHEMATICS AND COMPUTING↗

Atomic disorder in Gd 2 Zr 2 O 7 pyrochlore

Gd 2 Zr 2 O 7 pyrochlore with different degrees of cation disorder were synthesized by isothermal annealing at various temperatures (1100–1550 °C), and the related changes in the structure were investigated by ambient and high pressure x-ray diffraction (XRD) measurements. Unit cell parameters increase almost linearly with increasing treatment temperature. The degree of cation order in pyrochlore also increases with the increase of temperature, but saturates at ~60%. The compressibility of the pyrochlore structures decreases when the degree of cation order increases. Lastly, high pressure XRD measurements also indicate that the phase stability of Gd 2 Zr 2 O 7 is not very sensitive to the degree of atomic disorder in the pyrochlore structure.

36 MATERIALS SCIENCE↗

A Multi-Mission Testbed for Advanced Technologies

The mission of the Center for Space Integrated Microsystem (CSIM) at the Jet Propulsion Laboratory is to develop advanced avionics systems for future deep space missions. The Advanced Micro Spacecraft (AMS) task is building a multi-mission testbed facility to enable the infusion of CSIM technologies into future missions. The testbed facility will also perform experimentation for advanced avionics technologies and architectures to meet challenging power, performance, mass, volume, reliability, and fault tolerance of future missions. The testbed facility has two levels of testbeds: (1) a Proof-of-Concept (POC) Testbed and (2) an Engineering Model Testbed. The methodology of the testbed development and the process of technology infusion are presented in a separate paper in this conference. This paper focuses only on the design, implementation, and application of the POC testbed. Additional information is contained in the original extended abstract.

Chau, S. N.↗