Search NASA⌕ Search

Engineering topics

Langford, Andrew O.

Publications and source records attributed to Langford, Andrew O..

Quantifying TOLNet Ozone Lidar Accuracy During the 2014 DISCOVER-AQ and FRAPPE Campaigns

The Tropospheric Ozone Lidar Network (TOLNet) is a unique network of lidar systems that measure high-resolution atmospheric profiles of ozone. The accurate characterization of these lidars is necessary to determine the uniformity of the network calibration. From July to August 2014, three lidars, the TROPospheric OZone (TROPOZ) lidar, the Tunable Optical Profiler for Aerosol and oZone (TOPAZ) lidar, and the Langley Mobile Ozone Lidar (LMOL), of TOLNet participated in the Deriving Information on Surface conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) mission and the Front Range Air Pollution and Photochemistry Experiment (FRAPPA) to measure ozone variations from the boundary layer to the top of the troposphere. This study presents the analysis of the intercomparison between the TROPOZ, TOPAZ, and LMOL lidars, along with comparisons between the lidars and other in situ ozone instruments including ozonesondes and a P-3B airborne chemiluminescence sensor. The TOLNet lidars measured vertical ozone structures with an accuracy generally better than +/-15 % within the troposphere. Larger differences occur at some individual altitudes in both the near-field and far-field range of the lidar systems, largely as expected. In terms of column average, the TOLNet lidars measured ozone with an accuracy better than +/-5 % for both the intercomparison between the lidars and between the lidars and other instruments. These results indicate that these three TOLNet lidars are suitable for use in air quality, satellite validation, and ozone modeling efforts.

TOLNet↗

Airborne Measurements of Ozone and Other Trace Gases Captured by the Alpha Jet Atmospheric eXperiment (AJAX) During the 2016 California Baseline Ozone Transport Study (CABOTS)

In October 2015, the Environmental Protection Agency lowered the National Ambient Air Quality Standard for ozone (O3) from 75 ppbv to 70 ppbv. However, meeting the stricter air standards is a challenge for certain areas of California, like the San Joaquin Valley (SJV), where O3 levels are typically high due to topography, meteorology, and local emissions. Another factor potentially contributing to increased surface O3 is the trans-Pacific transport of O3 from Asia. The extent of which O3stems from local emissions or is transported across the Pacific, however, is unclear. The California Ozone Transport Study (CABOTS), a joint effort between the California Air Resource Board, the National Oceanic and Atmospheric Administration, and San Jose State University, was conducted during the spring and summer of 2016 in an attempt to answer this question.Nearly 10 science flights were carried out by the Alpha Jet Atmospheric eXperiment (AJAX) between June and August 2016, based out of the NASA Ames Research Center. A summary of airborne O3, CO2, CH4, H2O, formaldehyde (HCHO), and 3D wind measurements will be presented. AJAX flights connect the fixed-location measurements at Visalia (TOPAZ ozone lidar) and Bodega Bay (ozonesondes), while exploring the spatial heterogeneity of O3 concentrations across California and at various offshore locations. Preliminary analyses of these flights will investigate connections between offshore O3 and Central Valley O3. Vertical profiles, time series, and tracer-tracer correlations will be employed to identify the sources of O3 during these flights.

Iraci, Laura T.↗

Quantifying the Contribution of Thermally Driven Recirculation to a High-Ozone Event Along the Colorado Front Range Using Lidar

A high-ozone (O3) pollution episode was observed on 22 July 2014 during the concurrent Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) and Front Range Air Pollution and Photochemistry Experiment (FRAPPE) campaigns in northern Colorado. Surface O3 monitors at three regulatory sites exceeded the Environmental Protection Agency (EPA) 2008 National Ambient Air Quality Standard (NAAQS) daily maximum 8h average (MDA8) of 75ppbv. To further characterize the polluted air mass and assess transport throughout the event, measurements are presented from O3 and wind profilers, O3-sondes, aircraft, and surface-monitoring sites. Observations indicate that thermally driven upslope flow was established throughout the Colorado Front Range during the pollution episode. As the thermally driven flow persisted throughout the day, O3 concentrations increased and affected high-elevation Rocky Mountain sites. These observations, coupled with modeling analyses, demonstrate a westerly return flow of polluted air aloft, indicating that the mountain-plains solenoid circulation was established and impacted surface conditions within the Front Range.

Front Range Air Pollution and Photochemistry Exper↗

Ozone Lidar Observations for Air Quality Studies

Tropospheric ozone lidars are well suited to measuring the high spatio-temporal variability of this important trace gas. Furthermore, lidar measurements in conjunction with balloon soundings, aircraft, and satellite observations provide substantial information about a variety of atmospheric chemical and physical processes. Examples of processes elucidated by ozone-lidar measurements are presented, and modeling studies using WRF-Chem, RAQMS, and DALES/LES models illustrate our current understanding and shortcomings of these processes.

Ozone↗