Search NASA⌕ Search

Engineering topics

Larner, James M

Publications and source records attributed to Larner, James M.

Helical Tomotherapy-Based STAT RT: Dosimetric Evaluation for Clinical Implementation of a Rapid Radiation Palliation Program

Helical tomotherapy-based STAT radiation therapy (RT) uses an efficient software algorithm for rapid intensity-modulated treatment planning, enabling conformal radiation treatment plans to be generated on megavoltage computed tomography (MVCT) scans for CT simulation, treatment planning, and treatment delivery in one session. We compared helical tomotherapy-based STAT RT dosimetry with standard linac-based 3D conformal plans and standard helical tomotherapy-based intensity-modulated radiation therapy (IMRT) dosimetry for palliative treatments of whole brain, a central obstructive lung mass, multilevel spine disease, and a hip metastasis. Specifically, we compared the conformality, homogeneity, and dose with regional organs at risk (OARs) for each plan as an initial step in the clinical implementation of a STAT RT rapid radiation palliation program. Hypothetical planning target volumes (PTVs) were contoured on an anthropomorphic phantom in the lung, spine, brain, and hip. Treatment plans were created using three planning techniques: 3D conformal on Pinnacle{sup 3}, helical tomotherapy, and helical tomotherapy-based STAT RT. Plan homogeneity, conformality, and dose to OARs were analyzed and compared. STAT RT and tomotherapy improved conformality indices for spine and lung plans (CI spine = 1.21, 1.17; CI lung = 1.20, 1.07, respectively) in comparison with standard palliative anteroposterior/posteroanterior (AP/PA) treatment plans (CI spine = 7.01, CI lung = 7.30), with better sparing of heart, esophagus, and spinal cord. For palliative whole-brain radiotherapy, STAT RT and tomotherapy reduced maximum and mean doses to the orbits and lens (maximum/mean lens dose: STAT RT = 2.94/2.65 Gy, tomotherapy = 3.13/2.80 Gy, Lateral opposed fields = 7.02/3.65 Gy), with an increased dose to the scalp (mean scalp dose: STAT RT = 16.19 Gy, tomotherapy = 15.61 Gy, lateral opposed fields = 14.01 Gy). For bony metastatic hip lesions, conformality with both tomotherapy techniques (CI = 1.01 each) is superior to AP/PA treatments (CI = 1.21), as expected. Helical tomotherapy-based STAT RT treatment planning provides clinically acceptable dosimetry, with conformality and homogeneity that is superior to standard linac-based 3D conformal planning and is only slightly inferior to standard helical tomotherapy IMRT dosimetry. STAT RT facilitates rapid treatment planning and delivery for palliative radiation of patients with metastatic disease, with relative sparing of adjacent OARs compared with standard 3D conformal plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dynamic MRI of Grid-Tagged Hyperpolarized Helium-3 for the Assessment of Lung Motion During Breathing

Purpose: To develop a dynamic magnetic resonance imaging (MRI) tagging technique using hyperpolarized helium-3 (HP He-3) to track lung motion. Methods and Materials: An accelerated non-Cartesian k-space trajectory was used to gain acquisition speed, at the cost of introducing image artifacts, providing a viable strategy for obtaining whole-lung coverage with adequate temporal resolution. Multiple-slice two-dimensional dynamic images of the lung were obtained in three healthy subjects after inhaling He-3 gas polarized to 35%-40%. Displacement, strain, and ventilation maps were computed from the observed motion of the grid peaks. Results: Both temporal and spatial variations of pulmonary mechanics were observed in normal subjects, including shear motion between different lobes of the same lung. Conclusion: These initial results suggest that dynamic imaging of grid-tagged hyperpolarized magnetization may potentially be a powerful tool for observing and quantifying pulmonary biomechanics on a regional basis and for assessing, validating, and improving lung deformable image registration algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Rabbit Irradiation Platform for Outcome Assessment of Lung Stereotactic Radiosurgery

Purpose: To evaluate a helical tomotherapy-based rodent radiosurgery platform that reproduces human image-guided radiosurgery treatment to study radiobiologic effects of stereotactic radiosurgery on lung tissues using functional magnetic resonance imaging (MRI). Methods and Materials: Hypofractionated radisourgery (20 Gy x 3) was delivered to the right lung of three New Zealand rabbits using Helical TomoTherapy with MVCT image guidance. Contrast-enhanced MR perfusion, hyperpolarized helium-3 MR ventilation, and CT were obtained before radiation and monthly for 4 months after radiation. All MRI was performed on a 1.5-T whole-body scanner with broad-band capabilities. Results: Precise dose delivery to 1.6 cc of the lower right lung was achieved without additional immobilization. No deficits were detected at baseline with respect to perfusion and ventilation. Lung perfusion deficits in the irradiated lung regions began at 2 months after radiation and worsened with time. No ventilation deficits were observed after radiation. Decrease in lung CT density in irradiated regions was observed after radiation, but the changes were less significant than those in perfusion MRI. Conclusions: We demonstrated that highly conformal radiation can be reproducibly delivered to a small volume of rodent lung on a widely available clinical unit. The radiation-induced lung injury can be detected as early as 2 months after radiation with perfusion MRI. The primary pattern of injury agrees with previously reported endothelial damage to radiosurgical radiation doses. This experimental design provides a cost-effective methodology for producing radiosurgical injuries in rodents that reproduces current human treatments for studying radiation injury and agents that might affect it.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reproducibility of Interfraction Lung Motion Probability Distribution Function Using Dynamic MRI: Statistical Analysis

Purpose: To investigate the statistical reproducibility of craniocaudal probability distribution function (PDF) of interfraction lung motion using dynamic magnetic resonance imaging. Methods and Materials: A total of 17 subjects, 9 healthy volunteers and 8 lung tumor patients, underwent two to three continuous 300-s magnetic resonance imaging scans in the sagittal plane, repeated 2 weeks apart. Three pulmonary vessels from different lung regions (upper, middle, and lower) in the healthy subjects and lung tumor patients were selected for tracking, and the displacement PDF reproducibility was evaluated as a function of scan time and frame rate. Results: For both healthy subjects and patients, the PDF reproducibility improved with increased scan time and converged to an equilibrium state during the 300-s scan. The PDF reproducibility at 300 s (mean, 0.86; range, 0.70-0.96) were significantly (p < 0.001) increased compared with those at 5 s (mean, 0.65; range, 0.25-0.79). PDF reproducibility showed less sensitivity to imaging frame rates that were >2 frames/s. Conclusion: A statistically significant improvement in PDF reproducibility was observed with a prolonged scan time among the 17 participants. The confirmation of PDF reproducibility over times much shorter than stereotactic body radiotherapy delivery duration is a vital part of the initial validation process of probability-based treatment planning for stereotactic body radiotherapy for lung cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semiconductor Nanoparticles as Energy Mediators for Photosensitizer-Enhanced Radiotherapy

Purpose: It has been proposed that quantum dots (QDs) can be used to excite conjugated photosensitizers and produce cytotoxic singlet oxygen. To study the potential of using such a conjugate synergistically with radiotherapy to enhance cell killing, we investigated the energy transfer from megavoltage (MV) X-rays to a photosensitizer using QDs as the mediator and quantitated the enhancement in cell killing. Methods and Materials: The photon emission efficiency of QDs on excitation by 6-MV X-rays was measured using dose rates of 100-600 cGy/min. A QD-Photofrin conjugate was synthesized by formation of an amide bond. The role of Foerster resonance energy transfer in the energy transferred to the Photofrin was determined by measuring the degree of quenching at different QD/Photofrin molar ratios. The enhancement of H460 human lung carcinoma cell killing by radiation in the presence of the conjugates was studied using a clonogenic survival assay. Results: The number of visible photons generated from QDs excited by 6-MV X-rays was linearly proportional to the radiation dose rate. The Foerster resonance energy transfer efficiency approached 100% as the number of Photofrin molecules conjugated to the QDs increased. The combination of the conjugate with radiation resulted in significantly lower H460 cell survival in clonogenic assays compared with radiation alone. Conclusion: The novel QD-Photofrin conjugate shows promise as a mediator for enhanced cell killing through a linear and highly efficient energy transfer from X-rays to Photofrin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗