Search NASA⌕ Search

Engineering topics

Laursen, S.

Publications and source records attributed to Laursen, S..

Initial results from the Caltech/DRSI balloon-borne isotope experiment

The Caltech/DSRI balloonborne High Energy Isotope Spectrometer Telescope (HEIST) was flown successfully from Palestine, Texas on 14 May, 1984. The experiment was designed to measure cosmic ray isotopic abundances from neon through iron, with incident particle energies from approx. 1.5 to 2.2 GeV/nucleon depending on the element. During approximately 38 hours at float altitude, 100,000 events were recorded with Z or = 6 and incident energies approx. 1.5 GeV/nucleon. We present results from the ongoing data analysis associated with both the preflight Bevalac calibration and the flight data.

Schindler, S. M.↗

Initial results from the Caltech/DSRI balloon-borne isotope experiment

The Caltech/DSRI balloon-borne High Energy Isotope Spectrometer Telescope (HEIST) was flown successfully from Palestine, Texas on 14 May 1984. The experiment was designed to measure cosmic ray isotopic abundances from neon through iron, with incident particle energies from approximately 1.5 to 2.2 GeV/nucleon, depending on the element. During approximately 38 hours at float altitude, 10 to the 5th events were recorded with Z or = 6 and incident energies 1.5 GeV/nucleon. We present results from the ongoing data analysis associated with both the pre-flight Bevalac calibration and the flight data.

Schindler, S. M.↗

A Cerenkov - Delta E/Delta X experiment for measuring cosmic-ray isotopes from neon through iron

Cosmic-ray isotope masses are measured in a balloon-borne cosmic-ray experiment. Two Cerenkov counters and an NaI scintillator stack are used to determine changes in energy and in the Lorentz factor for a traversing or stopping particle. The mass is defined at the ratio of the change in energy to the change in the Lorentz factor. For incident elements from neon through iron, mass resolution better than 0.3 a.m.u. is expected, with incident Lorentz gammas ranging from 2.4 to 3.1, depending on the element. The mass resolution is approximately 0.2 a.m.u., measured for Mn-55 ions having an incident Lorentz factor of 2.75.

Buffington, A.↗

Calibration of an aerogel counter of index 1.1 at the Bevalac

The counter, which is exposed to sea level muons and to a beam of relativistic Mn-55, is 6 cm thick and approximmately 60 cm in diameter; it is viewed by twelve 12.7-cm-diameter photomultipliers. It comprises a mosaic with 48 aerogel pieces whose refractive indices are approximately 1.1. It is pointed out that a relativistic muon produces typically 23 + or - 4 photo-electrons. The light yield, which is mapped as a function of position, has an r.m.s. variation of less than 1 percent per cm. An analysis of the light yield suggests that absorption is important at short wavelengths. The calibration reveals that the light yield and uniformity of the counter are sufficient to determine particle velocity in the gamma range from 2.4 to 3.1.

Rasmussen, I. L.↗