Develop and Manufacture an Ergonomically Sound Glovebox Glove Report

Ergonomic injury and radiation exposure are two safety concerns for the Plutonium Facility at Los Alamos National Laboratory (LANL). This facility employs the largest number of gloveboxes (GB) at LANL with approximately 6000 gloves installed. The current GB glove design dates back to the 1960’s and is not based on true hand anatomy, revealing several issues: short fingers, inappropriate length from the wrist to finger webbing, nonexistent joint angles and incorrect thumb placement. These design flaws are directly related to elbow (lateral epicondylitis) and thumb (DeQuervain’s tenosynovitis) injuries. The current design also contributes to increased wear on the glove, causing unplanned glove openings (failures) which places workers at risk of exposure. An improved glovebox glove design has three significant benefits: 1) it will reduce the risk of injury, 2) it will improve comfort and productivity, and 3) it will reduce the risk of a glovebox failures. The combination of these three benefits has estimated savings of several million dollars. The new glove design incorporated the varied physical attributes of workers ranging from the 5 th percentile female to the 95th percentile male. Anthropometric hand dimensions along with current GB worker dimensions were used to develop the most comprehensive design specifications for the new glove. Collaboration with orthopedic hand surgeons also provided major contributtions to the design. The new glovebox glove was developed and manufactured incorporating over forty dimensions producing the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 “Protective Glove”, one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. The glove dimensions were inputed into a solid works model which was used to produce molds. The molds were then shipped to a glove manufacturer for production of the new glovebox gloves. The new glovebox gloves were tested against the presently used glovebox gloves for design validity. The testing included a subjective survey and four dexterity tests. The prototype was statistically significant in 3 dexterity tests and favorable on 8 out of 10 survey questions. The more ergonomically sound glovebox glove will improve worker comfort, mitigate glovebox worker injuries, and reduce glove breaches.

42 ENGINEERING↗

Rotator cuff strength balance in glovebox workers

Gloveboxes are essential to the pharmaceutical, semi-conductor, nuclear, and biochemical industries. While gloveboxes serve as effective containment systems, they are often difficult to work in and present a number of ergonomic hazards. One such hazard is injury to the rotator cuff, a group of tendons and muscles in the shoulder, connecting the upper arm to the shoulder blade. Rotator cuff integrity is critical to shoulder health. This study compared the rotator cuff muscle strength ratios of glovebox workers to the healthy norm. Descriptive statistics were collected using a short questionnaire. Handheld dynamometry was used to quantify the ratio of forces produced for shoulder internal and external rotation. Results showed this population to have shoulder strength ratios significantly different from the healthy norm. Strength ratios were found to be a sound predictor of symptom incidence. The deviation from the normal ratio demonstrates the need for solutions designed to reduce the workload on the rotator cuff musculature in order to improve health and safety. Assessment of strength ratios can be used to screen for risk of symptom development. As a result, this increases technical knowledge and augments operational safety.

60 APPLIED LIFE SCIENCES↗

Investigation of injury data at a detonator facility

This paper focuses on the collection of injury data; incorporation of this information into a visual format that DET management uses to make decisions to improving operations. Results from this 1 study include of the following: chemical exposure cases have declined because the Hazard Assessment of each DET operation has been formally reviewed; Slip/Trip/Fall factors have decreased due to Slip Simulator training; and work station evaluations have led to fewer injuries with Lift/Push/Pull factors. Rotation of employees, ergonomically friendly balances, automatic powder dispensers, and other equipment procurements will lower ergonomic injuries.

97 MATHEMATICS AND COMPUTING↗

Anatomy of an incident

A traditional view of incidents is that they are caused by shortcomings in human competence, attention, or attitude. It may be under the label of “loss of situational awareness,” procedure “violation,” or “poor” management. A different view is that human error is not the cause of failure, but a symptom of failure – trouble deeper inside the system. In this perspective, human error is not the conclusion, but rather the starting point of investigations. During an investigation, three types of information are gathered: physical, documentary, and human (recall/experience). Through the causal analysis process, apparent cause or apparent causes are identified as the most probable cause or causes of an incident or condition that management has the control to fix and for which effective recommendations for corrective actions can be generated. A causal analysis identifies relevant human performance factors. In the following presentation, the anatomy of a radiological incident is discussed, and one case study is presented. We analyzed the contributing factors that caused a radiological incident. When underlying conditions, decisions, actions, and inactions that contribute to the incident are identified. This includes weaknesses that may warrant improvements that tolerate error. Measures that reduce consequences or likelihood of recurrence are discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

A glove-likeability study of specially-treated gloves in the detonator manufacturing and packaging industry

We use hand gloves (hereafter referred to as gloves) in the detonator manufacturing and packaging operations. As part of a process improvement program, new glove formulations have been considered that lower the overall risk of detonator operations by reducing ergonomic injury factors. Gloves with a specially treated surface for extra grip and control are now commercially available and have been recommended for use in detonator operations. A Glove Likeability Study demonstrated that detonator manufacturing and packaging workers prefer gloves with a specially treated surface over currently approved gloves made from latex and nitrile formulations. Glove material compatibility tests indicate that the recommended gloves are as compatible if not more compatible as the currently approved gloves for working with secondary explosives. Thus, these gloves with a specially treated surface for extra grip and control are now available for tasks where sensitivity and fingertip control are crucial. Replacement of the current gloves with gloves with a specially treated surface improves the safety configuration of detonator manufacturing and packaging operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Develop and Manufacture an airlock sliding tray

The goal of this project is to continue to develop an airlock sliding tray and then partner with an industrial manufacturing company for production. The sliding tray will be easily installed into and removed from most glovebox airlocks in a few minutes. Technical Approach: A prototype of a sliding tray has been developed and tested in the LANL cold lab and 35 trays are presently being built for the plutonium facility (PF-4). The current, recently approved design works for a 14-inch diameter round airlock and has a tray length of approximately 20 inches. The grant will take the already tested and approved round technology and design for the square airlock. These two designs will be suitable for the majority of the existing airlocks in the multitude of DOE facilities. Partnering with an external manufacturer will allow for production of the airlock trays at a much lower cost and increase the availability of the product for all DOE sites. Project duration is estimated to be 12-13 months. Benefits: The purpose of the airlock sliding trays is fourfold: 1) Mitigate risk of rotator cuff injuries, 2) Improve ALARA, 3) Reduce risk of glovebox glove breaches and glove punctures, and 4) Improve worker comfort. I have had the opportunity to visit many other DOE facilities including Savannah, Y-12, ORNL, Sandia, and Livermore for assistance with ergonomic problems and/or injuries. All of these sites would benefit from the airlock sliding tray and I can assume all other DOE facilities with gloveboxes built prior to 1985 could also use the sliding trays.

42 ENGINEERING↗

Manipulator Report for Pacific Northwest 2016

An initial ergonomic evaluation of the manipulators in was performed in 2007 and again in 2008. Discussion and solution development was performed with the new management team, FLM, and the employee on March 23, 2009. The purpose of this evaluation was to identify improvements to reduce stress and risk of injury to the employees. The primary ergonomic related risk factors identified include static and awkward postures especially for the wrist, and repetitive motion of fine motor musculature of the hand and forearm depending on the work load. This memorandum is intended as a starting point to reduce the ergonomic-related risk factors present in this process. All risk factors were probably not identified during this initial evaluation due to limited task demonstrations. The solution development and implementation process is a team effort. The Ergonomics Team provides technical support and guidance; employees demonstrate tasks, provide ideas, and test and provide feedback on potential solutions; and management provides the resources and encourages participation in the process.

42 ENGINEERING↗