Search NASA⌕ Search

Engineering topics

Le, Thanh

Publications and source records attributed to Le, Thanh.

Rational optimization of substituted α–MnO 2 cathode for aqueous zinc–ion battery

Density functional theory (DFT) is utilized to explore the effects of increasing concentrations of vanadium (V) and chromium (Cr) substitution on the discharge of α-MnO 2 cathode in hydrated zinc-ion batteries (ZIBs). During H + -intercalation and Zn 2+ -intercalation, Cr-substitution proves to be more effective than V-substitution in promoting discharge behaviors. Transitioning from Mn 0.875 Cr 0.125 O 2 , Mn 0.75 Cr 0.25 O 2 to Mn 0.625 Cr 0.375 O 2 is found to consistently enhance the discharge voltage, along with improved tunnel structure retention and volume expansion suppression. In comparison, the promoting effect of increasing V-substitution is relatively small at initial discharge stages and leads to degradation at later stages, primarily due to an increased concentration of unstable Mn 2+ ion. The superior effect of Cr-substitution is attributed to the unique atomic and electronic structures of substituted Cr 4+ and reduced Cr 3+ ions during discharge. These ions serve as active electron acceptors to limit the formation of Mn 3+ and Mn 2+ ions, and as anchors to stabilize the α-MnO 2 framework and intercalated H + /Zn 2+ ions, respectively. Finally, our study highlights fine-tuning through substitution to enhance the performance of α-MnO 2 -based cathode materials in ZIBs.

25 ENERGY STORAGE↗

Tuning Discharge Behavior of Hollandite α-MnO 2 in Hydrated Zinc Ion Battery by Transition Metal Substitution

The tunnel-type hollandite α-MnO 2 is a promising cathode material for rechargeable aqueous zinc-ion batteries (ZIBs) due to its low cost in synthesis and high energy density. However, irreversible structural degradation upon continuous cycling prevents the cathode from being utilized commercially. Herein, density functional theory (DFT) was utilized to conduct a systematic study on tuning the behavior of α-MnO 2 by substituting the Mn ions on the tunnel wall with a transition metal (V or Cr) during the H + -/Zn 2+ -intercalation in hydrated ZIB. Our study revealed that both substituents aid cyclability and capacity retention with Cr outperforming V. In term of discharge voltage, only the Cr-substitution displays clear promotion at the early stage of discharge. The superior performance of substituted Cr 4+ comes from its unique atomic and electronic structures. Upon discharge, it can be reduced to Cr 3+ more readily than Mn 4+ and thereby limits the formation of unstable Mn 3+ or Mn 2+ centers; the formed Cr 3+ is more stable than Mn 3+ and Mn 2+ from the reduction of Mn 4+ ; and Cr 3+ can also greatly stabilize the neighboring Mn ions. Here this study highlights the significant tuning effect of transition metal substitution on the electrochemical and physical performance of α-MnO 2 as a cathode in hydrated ZIBs.

25 ENERGY STORAGE↗

In-Flight Verification and Validation of Colloid Microthruster Performance

Colloid Micronewton Thrusters (CMNTs) use an electrospray to provide precision spacecraft position and pointing control. They were demonstrated in space for the first time as part of NASA’s Space Technology 7 (ST7) payload hosted by the European Space Agency’s (ESA’s) LISA Pathfinder (LPF) technology demonstration mission in January, 2016. CMNTs were the actuator in the disturbance reduction system (DRS) that provided drag-free operation of the LPF spacecraft, which will be necessary for future gravity wave observatories such as ESA’s Laser Interferometer Space Antenna (LISA) mission, currently in Phase A and scheduled for launch in 2034. The CMNT technology met performance requirements operating at 5-30 µN of thrust with 0.1 µN resolution and ≤0.1 µN/ÖHz thrust noise to deliver the required nanometer-level precision spacecraft control measured by the gravitational reference sensor (GRS) in the ESA LISA Technology Package (LTP). The performance of seven of the eight CMNTs in flight was consistent with ground test results, and as a system, all eight thrusters met mission-level performance requirements. The colloid microthruster performance model of thrust and thrust noise as a function of operational parameters (i.e. beam current, voltage, temperature, etc.) was validated in flight over a wide range of conditions. A model and simulation of the thruster control algorithm was developed and validated with flight data to predict thrust noise. This capability is important for future missions because it relates directly to the acceleration noise on the test masses, which provide the gravity wave measurements. The CMNT thruster model data and validation with LISA Pathfinder/ST7-DRS flight experiments are presented in this paper.

"O'Donnell, James"↗

ST7 Disturbance Reduction System (DRS) Colloid Micronewton Thruster Performance and Control Algorithm Model Simulation Validation in Flight

Colloid Micronewton Thrusters (CMNT) were flight demonstrated for the first time on the ST7Disturbance Reduction System (DRS) payload on the European Space Agency (ESA) Laser Interferometer Space Antenna (LISA) Pathfinder spacecraft for attitude and drag-free spacecraft control. LISA Pathfinder was a technology demonstration mission for ESA’s LISA gravitational wave observatory, currently in Phase A with a launch date of 2034. The DRS included the Integrated Avionics Unit (IAU), eight Colloid Micronewton Thrusters (CMNT), Dynamic Control Software (DCS) and Flight Software (FSW). The CMNT technology met performance requirements operating at 5-30 µN of thrust with ≤0.1 µN resolution and ≤0.1 µN/Hz thrust noise to deliver the required nanometer-level precision spacecraft control measured by the gravitational reference sensor (GRS) in the ESA LISA Technology Package (LTP). The performance of seven of the CMNT in flight was consistent with ground test results. The colloid thruster performance model of thrust and thrust noise as a function of operational parameters (i.e. beam current, voltage, temperature, etc.) was validated in flight over a wide range of conditions. A model and simulation of the thruster control algorithm was developed and validated with flight data to predict thrust noise. This capability is important because it is considered to be a significant source of position noise on the spacecraft and, therefore, the acceleration noise on the test masses, which provide the gravity wave measurements. The CMNT thruster model data and validation with LISA Pathfinder/ST7-DRS flight experiments are discussed in this paper.

Hruby, Vlad↗

Demonstration of Long Vacuum Integrity Lifetime of Trapped Ion Standard Package

A compact Hg ion trap package that was vacuum-sealed since 9 years has been demonstrated to be successfully operational showing excellent ion-trap lifetime exceeding 400 days. In addition to the vacuum package, the same 9-year old optical and detection packages are utilized to obtain these results. Charge transfer relaxation effects between neutral Hg and trapped Hg ion are studied. This work shows the reliability of such units in view of next-generation ground and space-borne trapped ion clocks.

charge-transfer relaxation↗

A Solid State Ultraviolet Lasers Based on Cerium-Doped LiCaAIF(sub 6) Crystal Resonator

We report the first demonstration of a UV laser using a high-Q whispering gallery mode (WGM) resonator of Ce+: LiCaAlF6. We show that WGM resonators from LiCaAlF6 can achieve a Q of 2.6 x 10(sup 7) at UV. We demonstrated a UV laser at 290 nm with a pulsed pump laser at 266 nm. The experiments showed the low pump threshold intensity of 7.5 x 10(sup 9) W/m(sup 2) and slope efficiency of 25%. We have also observed lasing delay dynamics. These results are consistent with our modeling and theoretical estimates, and pave the way for a low threshold cw UV laser using WGM resonator cavity.

Whispering Gallery Mode Resonators↗

Integrated Miniature Arrays of Optical Biomolecule Detectors

Integrated miniature planar arrays of optical sensors for detecting specific biochemicals in extremely small quantities have been proposed. An array of this type would have an area of about 1 cm2. Each element of the array would include an optical microresonator that would have a high value of the resonance quality factor (Q . 107). The surface of each microresonator would be derivatized to make it bind molecules of a species of interest, and such binding would introduce a measurable change in the optical properties of the microresonator. Because each microresonator could be derivatized for detection of a specific biochemical different from those of the other microresonators, it would be possible to detect multiple specific biochemicals by simultaneous or sequential interrogation of all the elements in the array. Moreover, the derivatization would make it unnecessary to prepare samples by chemical tagging. Such interrogation would be effected by means of a grid of row and column polymer-based optical waveguides that would be integral parts of a chip on which the array would be fabricated. The row and column polymer-based optical waveguides would intersect at the elements of the array (see figure). At each intersection, the row and column waveguides would be optically coupled to one of the microresonators. The polymer-based waveguides would be connected via optical fibers to external light sources and photodetectors. One set of waveguides and fibers (e.g., the row waveguides and fibers) would couple light from the sources to the resonators; the other set of waveguides and fibers (e.g., the column waveguides and fibers) would couple light from the microresonators to the photodetectors. Each microresonator could be addressed individually by row and column for measurement of its optical transmission. Optionally, the chip could be fabricated so that each microresonator would lie inside a microwell, into which a microscopic liquid sample could be dispensed.

Iltchenko, Vladimir↗

Efficient Coupler for a Bessel Beam Dispersive Element

A document discusses overcoming efficient optical coupling to high orbital momentum modes by slightly bending the taper dispersive element. This little shape distortion is not enough to scramble the modes, but it allows the use of regular, free-beam prism coupling, fiber coupling, or planar fiber on-chip coupling with, ultimately, 100 percent efficiency. The Bessel-beam waveguide is bent near the contact with the coupler, or a curved coupler is used. In this case, every Bessel-beam mode can be successfully coupled to a collimated Gaussian beam. Recently developed Bessel-beam waveguides allow long optical delay and very high dispersion. Delay values may vary from nanoseconds to microseconds, and dispersion promises to be at 100 s/nm. Optical setup consisted of a red laser, an anamorphic prism pair, two prism couplers, and a bent, single-mode fiber attached to prisms. The coupling rate increased substantially and corresponded to the value determined by the anamorphic prism pair.

Savchenkov, Anatoliy↗

Direct Coupling From WGM Resonator Disks to Photodetectors

Output coupling of light from a whispering- gallery-mode (WGM) optical resonator directly to a photodetector has recently been demonstrated. By directly is meant that the coupling is effected without use of intervening optical components. Heretofore, coupling of light into and out of WGM resonators has been a complex affair involving the use of such optical components as diamond or glass prisms, optical fibers, coated collimators, and/or fiber tapers. Alignment of these components is time-consuming and expensive. To effect direct coupling, one simply mounts a photodetector in direct mechanical contact with a spacer that is, in turn, in direct mechanical contact with a WGM resonator disk. The spacer must have a specified thickness (typically of the order of a wavelength) and an index of refraction lower, by an adequate margin, than the indices of refraction of the photodetector and the WGM resonator disk. This mechanically simple approach makes it possible to obtain an optimum compromise between maximizing optical coupling and maximizing the resonance quality factor (Q).

Savchenkov, Antoliy↗

Miniaturized Mercury Ion Clock for Ultrastable Deep Space Applications

We have recently completed a prototype ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability ~2-3x10-13 at 1 second, averaging to 10-15 at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-13 at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly 1.5 years with no measurable degradation of ion trapping lifetimes or clock short-term performance. Because the tube is sealed, the Hg source and Neon buffer gas are held indefinitely, for the life of the tube. There is no consumption of Hg in this system unlike in a Cs beam tube where lifetime is often limited by Cs depletion.

mercury ion clocks↗

Improved Measurement of Dispersion in an Optical Fiber

An improved method of measuring chromatic dispersion in an optical fiber or other device affords a lower (relative to prior such methods) limit of measurable dispersion. This method is a modified version of the amplitude-modulation (AM) method, which is one of the prior methods. In comparison with the other prior methods, the AM method is less complex. However, the AM method is limited to dispersion levels . 160 ps/nm and cannot be used to measure the symbol of the dispersion. In contrast, the present modified version of the AM method can be used to measure the symbol of the symbol of the dispersion and affords a measurement range from about 2 ps/nm to several thousand ps/nm with a resolution of 0.27 ps/nm or finer. The figure schematically depicts the measurement apparatus. The source of light for the measurement is a laser, the wavelength of which is monitored by an optical spectrum analyzer. A light-component analyzer amplitude-modulates the light with a scanning radio-frequency signal. The modulated light is passed through a buffer (described below) and through the device under test (e.g., an optical fiber, the dispersion of which one seeks to measure), then back to the light-component analyzer for spectrum analysis. Dispersion in the device under test gives rise to phase shifts among the carrier and the upper and lower sideband components of the modulated signal. These phase shifts affect the modulation-frequency component of the output of a photodetector exposed to the signal that emerges from the device under test. One of the effects is that this component goes to zero periodically as the modulation frequency is varied.

Huang, Shouhua↗

Proceedings of the 2004 NASA/JPL Workshop on Physics for Planetary Exploration

The conference was held April 20-22, 2004, the NASA/JPL Workshop on Physics for Planetary Exploration focused on NASA's new concentration on sending crewed missions to the Moon by 2020 and then to Mars and beyond. However, our ground-based physics experiments are continuing to be funded, and it will be possible to compete for $80-90 million in new money from the NASA exploration programs. Papers presented at the workshop related how physics research can help NASA to prepare for and accomplish this grand scheme of exploration. From sensors for water on the Moon and Mars, to fundamental research on those bodies, and to aids for navigating precisely to landing sites on distant planets, diverse topics were addressed by the Workshop speakers.

Strayer, Donald M.↗

Small Mercury Ion Clock for On-board Spacecraft Navigation

I.Small Ion Clock Approach and Heritage: a) No lasers, uwave cavities, cryogenics, atomic beams, etc. b) Ions are electrically shuttled between separate optical and microwave traps. II. Each trap is optimized for its task: quadrupole for optical state selection; multi-pole for microwave clock. a) Very good stability shown in USNO. Timescale running "open loop." III. "Open loop" operation means no self-measurements of frequency offsets: (Zeeman, ion temperature,... etc.) a) Fewer parts and procedures, produces stable output continuously. IV. Ion clock is not so sensitive to temperature fluctuations a) Measured u:nshielded temperature coefficient of few 10(exp -15) per C. b) No bulky temperature isolation needed.

Prestage, John D.↗

One liter ion clock : new capability for spaceflight applications

We describe the development of a small Hg ion clock suitable for space use. The breadboard physics package is 1-2 liters in volume, produces frequency stability of 10-13√τ and should significantly advance the state of space-qualified atomic clocks.

Tjoelker, Robert L.↗

One-liter Hg ion clock for space and ground applications

We describe the development of a small Hg ion clock suitable for space use. A small clock occupying 1-2 liters volume and producing stability of 10 to the power negative twelve, divided by square root pi would significantly advance the state of space-qualified atomic clocks. Based on recent measurements, this technology should produce long-term stability as good as 10 to the power negative fifteen.

ion clock↗