Search NASA⌕ Search

Engineering topics

Lee Stone

Publications and source records attributed to Lee Stone.

Risk Trade-Space Analysis for Safe Human Expeditions to Mars

We assessed the integrated safety, health, and performance risk to crews on long-duration missions, specifically to Mars. Using a systems approach rather than one focused on individual countermeasures, we examined the trade space around several such risks to identify high-potential risk mitigation strategies and characterize aspects of Mars mission architectures that could lower aggregated risk. Current Mars Design Reference missions would require durations well over two years and would increase crew exposure to radiation and microgravity well beyond ISS levels, likely resulting in significantly reduced performance beyond our current capability to mitigate that could jeopardize mission success. A “fast Mars transit” round-trip mission concept was studied using an innovative flight dynamics approach to quantify the minimum total mission energy required for a Mars transit with total mission duration less than 400 days. This approach holds promise for sending humans to Mars and returning them safely with acceptable, potentially mitigatable, exposure to microgravity and radiation using current or near-term technologies. The fast transit concept would also result in fewer time-driven vehicle failures and enable sustainable deployment of humans and infrastructure to Mars on a regular cadence, allowing steady exploration and colonization of Mars. Finally, we conclude that reliance on the Low Earth Orbit (LEO) mission operations paradigm – i.e., one of near-complete real-time dependence on experts at Mission Control to manage the combined state of the mission, vehicle, and crew – is high risk given the communication delays and limited resupply of any Mars mission, and this risk is not eliminated by the shorter missions durations of fast transit scenarios. Based on historical trends, it is highly likely that the crew will face a high-consequence problem of uncertain origin during Mars transit when ground support will be greatly reduced. While it may be possible to reduce anomaly rates through improved reliability analysis and testing, and to reduce anomaly impacts through added robustness, such mitigations address only known failure modes and known uncertainties. Therefore, a radical shift in the Human-Systems Integration Architecture (HSIA) that defines the operational paradigm, systems design, and human-systems interactions is required to improve the risk posture to an acceptable level regardless of mission duration.

Mars↗

Oculometric Detection and Characterization of Sub-Clinical Visual/Visuomotor Impairment

It has long been known that qualitative abnormalities in eye movements can be used to diagnose overt brain pathologies (Diefendorf & Dodge, 1908; Fox & Holmes, 1926; Leigh & Zee, 2015). Here, we will examine the use of a set of quantitative measures of the human behavioral response (oculometrics) in a 5-minute radial ocular tracking task (Krukowski & Stone, 2005) with sufficient temporal, spatial, and directional uncertainty to minimize the contribution of a priori prediction or anticipation, and to emphasize the use of a posteriori visual processing of the stimulus trajectory (Liston & Stone, 2014). The derived oculometrics provide a largely independent, reliable set of metrics that are sensitive enough to detect mild sub-clinical impairment across a range of possible neural loci (Stone et al., 2019) with the pattern of impairment across the set providing specificity as to its nature (Tyson et al., 2023). We will review our earlier findings where oculometrics have been used to detect mild impairment due to traumatic brain injury, sleep loss, and low-dose alcohol (Liston et al., 2017; Stone et al., 2019; Tyson et al., 2021). We will also report on a recent clinical study of asymptomatic patients at risk of retinal pathology (Leung et al., 2022) and show that oculometrics can detect and characterize substantive loss of visual function in the absence of clinical indicators of pathology. We conclude that oculometric testing could be used as a routine non-invasive ophthalmological or neurological tool to aid in the early detection and diagnosis of neural injury, toxicity, or disease.

eye movements↗

Efficient Oculometric Assessment of Altered Neural Function

Eye movements have long been known to shed light on the locus and nature of serious brain injuries and pathologies. Recent scientific findings linking eye movements and higher-order psychometric performance and recent technical advances in eye-tracking precision have enabled the harnessing of an assortment of oculometrics as sensitive and reliable biomarkers of mild neural impairment across a wide range of stressors and brain regions. Oculometrics is, therefore, a promising new tool for the assessment of spaceflight effects on sensorimotor performance and on the effectiveness of candidate countermeasures, even with small sample populations

eye movements↗