Search NASA⌕ Search

Engineering topics

Lee, H

Publications and source records attributed to Lee, H.

At least 37 records · Page 2

SU-E-T-516: Investigation of a Novel Radiochromic Radiation Reporting System Utilizing the Reduction of Ferric Ion

Purpose To introduce and characterize a new “reverse-Fricke” radiation reporting system utilizing the reduction of ferric ions (Fe{sup 3+}) to ferrous ions (Fe{sup 2+}). Methods Two formulations of the radiochromic reporting system, referred to as A and B, were prepared for investigation. Formulation-A consisted of 14 mM 1,10-phenanthroline, 42 mM ethanol, and 57 mM ammonium ferric oxalate in water. Formulation-B consisted of 27 mM 1,10-phenanthroline, 42 mM ethanol, and 28 mM ammonium ferric oxalate in water. Solutions were prepared immediately prior to irradiation with a Cobalt-60 unit with radiation doses of 0, 1, 5, 10, 15, 20, and 25 Gy. The change in optical density over the visible range of 450–650 nm was measured using a spectrophotometer immediately after irradiation. The effective atomic numbers of the formulations were calculated using Mayneord’s formula. Results Ionizing radiation energy absorbed in the solutions causes the reduction of ferric ions (Fe{sup 3+}) into ferrous ions (Fe{sup 2+}), which then forms a 1:3 red colored complex with 1,10-phenanthroline ([(C{sub 1} {sub 2}H{sub 8}N{sup 2}){sub 3}Fe]{sup 2+}) that can be measured spectrophotometrically. The absorbance spectra of the resulting complex displayed a peak maximum at 512 nm with a greater change in absorbance for Formulation-B after receiving comparable radiation doses. The change in absorbance relative to dose exhibited a linear response up to 25 Gy for both Formulation-A (R{sup 2} = 0.98) and Formulation-B (R{sup 2} = 0.97). The novel formulations were also nearly water equivalent (Zeff = 7.42) with effective atomic numbers of 7.65 and 7.52 and mass densities within 0.2% of water. Conclusion Both formulations displayed visible Fe{sup 2+} complex formation with 1,10-phenanthroline after irradiation using a Cobalt-60 source. The higher sensitivity measured for Formulation-B is attributed to the increase in 1,10-phenanthroline concentration and the increase in the 1,10-phenanthroline to ammonium ferric oxalate ratio. Further investigation of this radiation reporting system in a 3D matrix material is encouraged. NSF GRFP Grant Award #LH-102SPS.

60 APPLIED LIFE SCIENCES↗

SU-E-T-812: Volumetric Modulated Arc Therapy-Total Body Irradiation (VMAT-TBI) V.s. Conventional Extended SSD-TBI (cTBI): A Dosimetric Comparisom

Purpose: To perform a dosimetric evaluation on a new developed volumetric modulated arc therapy based total body irradiation (VMAT-TBI). Methods: Three patients were CT scanned with an indexed rotatable body frame to get whole body CT images. Concatenated CT images were imported in Pinnacle treatment planning system and whole body and lung were contoured as PTV and organ at risk, respectively. Treatment plans were generated by matching multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. For each plan, 1200 cGy in 8 fractions was prescribed to the whole body volume and the lung dose was constrained to a mean dose of 750 cGy. Such a two-level dose plan was achieved by inverse planning of the torso VMAT fields. For comparison, conventional standing TBI (cTBI) plans were generated on the same whole body CT images at an extended SSD (550cm).The shape of compensators and lung blocks are simulated using body segments and lung contours Compensation was calculated based on the patient CT images, in mimic of the standing TBI treatment. The whole body dose distribution of cTBI plans were calculated with a home-developed GPU Monte Carlo dose engine. Calculated cTBI dose distribution was prescribed to the mid-body point at umbilical level. Results: The VMAT-TBI treatment plans of three patients’ plans achieved 80.2%±5.0% coverage of the total body volume within ±10% of the prescription dose, while cTBI treatment plans achieved 72.2%±4.0% coverage of the total body volume. The averaged mean lung dose of all three patients is lower for VMAT-TBI (7.48 cGy) than for cTBI (8.96 cGy). Conclusion: The proposed patient comfort-oriented VMAT-TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.

60 APPLIED LIFE SCIENCES↗

MO-FG-303-04: A Smartphone Application for Automated Mechanical Quality Assurance of Medical Accelerators

Purpose: The mechanical quality assurance (QA) of medical accelerators consists of a time consuming series of procedures. Since most of the procedures are done manually – e.g., checking gantry rotation angle with the naked eye using a level attached to the gantry –, it is considered to be a process with high potential for human errors. To remove the possibilities of human errors and reduce the procedure duration, we developed a smartphone application for automated mechanical QA. Methods: The preparation for the automated process was done by attaching a smartphone to the gantry facing upward. For the assessments of gantry and collimator angle indications, motion sensors (gyroscope, accelerator, and magnetic field sensor) embedded in the smartphone were used. For the assessments of jaw position indicator, cross-hair centering, and optical distance indicator (ODI), an optical-image processing module using a picture taken by the high-resolution camera embedded in the smartphone was implemented. The application was developed with the Android software development kit (SDK) and OpenCV library. Results: The system accuracies in terms of angle detection error and length detection error were < 0.1° and < 1 mm, respectively. The mean absolute error for gantry and collimator rotation angles were 0.03° and 0.041°, respectively. The mean absolute error for the measured light field size was 0.067 cm. Conclusion: The automated system we developed can be used for the mechanical QA of medical accelerators with proven accuracy. For more convenient use of this application, the wireless communication module is under development. This system has a strong potential for the automation of the other QA procedures such as light/radiation field coincidence and couch translation/rotations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-10: A Moving-Blocker-Based Strategy for Simultaneous Megavoltage and Kilovoltage Scatter Correction in Cone-Beam Computed Tomography Image Acquired During Volumetric Modulated Arc Therapy

Purpose: To evaluate a moving-blocker-based approach in estimating and correcting megavoltage (MV) and kilovoltage (kV) scatter contamination in kV cone-beam computed tomography (CBCT) acquired during volumetric modulated arc therapy (VMAT). Methods: XML code was generated to enable concurrent CBCT acquisition and VMAT delivery in Varian TrueBeam developer mode. A physical attenuator (i.e., “blocker”) consisting of equal spaced lead strips (3.2mm strip width and 3.2mm gap in between) was mounted between the x-ray source and patient at a source to blocker distance of 232mm. The blocker was simulated to be moving back and forth along the gantry rotation axis during the CBCT acquisition. Both MV and kV scatter signal were estimated simultaneously from the blocked regions of the imaging panel, and interpolated into the un-blocked regions. Scatter corrected CBCT was then reconstructed from un-blocked projections after scatter subtraction using an iterative image reconstruction algorithm based on constraint optimization. Experimental studies were performed on a Catphan 600 phantom and an anthropomorphic pelvis phantom to demonstrate the feasibility of using moving blocker for MV-kV scatter correction. Results: MV scatter greatly degrades the CBCT image quality by increasing the CT number inaccuracy and decreasing the image contrast, in addition to the shading artifacts caused by kV scatter. The artifacts were substantially reduced in the moving blocker corrected CBCT images in both Catphan and pelvis phantoms. Quantitatively, CT number error in selected regions of interest reduced from 377 in the kV-MV contaminated CBCT image to 38 for the Catphan phantom. Conclusions: The moving-blockerbased strategy can successfully correct MV and kV scatter simultaneously in CBCT projection data acquired with concurrent VMAT delivery. This work was supported in part by a grant from the Cancer Prevention and Research Institute of Texas (RP130109) and a grant from the American Cancer Society (RSG-13-326-01-CCE)

60 APPLIED LIFE SCIENCES↗

SU-E-T-306: Study of the Reduction Technique for the Secondary Cancer Risk Due to Cone Beam CT in Image Guided Radiotherapy

Purpose: This study evaluated the effectiveness of a thin lead sheet based simple shielding method for imaging doses from cone beam computed tomography (CBCT) in image-guided radiotherapy (IGRT). Methods: The entire body, except for the region scanned by CBCT, was shielded by wrapping in a 2 mm lead sheet. Reduction of secondary doses from CBCT was measured using a radio-photoluminescence glass dosimeter (RPLGD) placed inside an anthropomorphic phantom and changes in secondary cancer risk due to the shielding effect were estimated using BEIR VII model. Results: Doses to out-of-field organs for head-and-neck, chest, and pelvis scans were decreased 15∼100 %, 23∼90 %, and 23∼98 %, respectively, and the average reductions in lifetime secondary cancer risk due to the 2 mm lead shielding were 1.61, 10.4, and 12.8 persons per 100,000, respectively. Conclusion: This study suggests that a simple thin lead sheet based shielding method results in a non-negligible reduction of secondary doses to out-of-field regions for CBCT.

60 APPLIED LIFE SCIENCES↗

SU-E-T-322: The Evaluation of the Gafchromic EBT3 Film in Low Dose 6 MV X-Ray Beams with Different Scanning Modes

Purpose: We have evaluated the response of the Gafchromic EBT3 film in low dose for 6 MV x-ray beams with two scanning modes, the reflection scanning mode and the transmission scanning mode. Methods: We irradiated the Gafcromic EBT3 film using a 60 degree enhanced dynamic wedge (EDW) with 6 MV x-ray beams from Clinac iX Linear accelerator (Varian Medical Systems, Palo Alto, CA). The irradiated Gafchromic EBT3 film was scanned with different scanning modes, the reflection scanning mode and the transmission scanning mode. The scanned Gafchromic EBT3 film was analyzed with MATLAB. Results: When 7.2 cGy was irradiated to the Gafchromic EBT3 film, the uncertainty was 0.54 cGy with reflection scanning mode and was 0.88 cGy with transmission scanning mode. When 24 cGy was irradiated to the Gafchromic EBT3 film, the uncertainty was similar to the case of 7.2 cGy irradiation showing 0.51 cGy of uncertainty with reflection scanning mode and 0.87 cGy of uncertainty with transmission scanning mode. The result suggests that the reflection mode should be used in Gafchromic EBT3 film for low irradiation. Conclusion: The result suggests that the reflection mode should be used in Gafchromic EBT3 film for low irradiation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-347: Validation of the Condensed History Algorithm of Geant4 Using the Fano Test

Purpose: To validate the condensed history algorithm and physics of the Geant4 Monte Carlo toolkit for simulations of ionization chambers (ICs). This study is the first step to validate Geant4 for calculations of photon beam quality correction factors under the presence of a strong magnetic field for magnetic resonance guided linac system applications. Methods: The electron transport and boundary crossing algorithms of Geant4 version 9.6.p02 were tested under Fano conditions using the Geant4 example/application FanoCavity. User-defined parameters of the condensed history and multiple scattering algorithms were investigated under Fano test conditions for three scattering models (physics lists): G4UrbanMscModel95 (PhysListEmStandard-option3), G4GoudsmitSaundersonMsc (PhysListEmStandard-GS), and G4WentzelVIModel/G4CoulombScattering (PhysListEmStandard-WVI). Simulations were conducted using monoenergetic photon beams, ranging from 0.5 to 7 MeV and emphasizing energies from 0.8 to 3 MeV. Results: The GS and WVI physics lists provided consistent Fano test results (within ±0.5%) for maximum step sizes under 0.01 mm at 1.25 MeV, with improved performance at 3 MeV (within ±0.25%). The option3 physics list provided consistent Fano test results (within ±0.5%) for maximum step sizes above 1 mm. Optimal parameters for the option3 physics list were 10 km maximum step size with default values for other user-defined parameters: 0.2 dRoverRange, 0.01 mm final range, 0.04 range factor, 2.5 geometrical factor, and 1 skin. Simulations using the option3 physics list were ∼70 – 100 times faster compared to GS and WVI under optimal parameters. Conclusion: This work indicated that the option3 physics list passes the Fano test within ±0.5% when using a maximum step size of 10 km for energies suitable for IC calculations in a 6 MV spectrum without extensive computational times. Optimal user-defined parameters using the option3 physics list will be used in future IC simulations to calculate beam quality correction factors under the presence of a magnetic field. Elekta-MD Anderson Research Agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-540: Volumetric Modulated Total Body Irradiation Using a Rotational Lazy Susan-Like Immobilization System

Purpose: Traditional extended SSD total body irradiation (TBI) techniques can be problematic in terms of patient comfort and/or dose uniformity. This work aims to develop a comfortable TBI technique that achieves a uniform dose distribution to the total body while reducing the dose to organs at risk for complications. Methods: To maximize patient comfort, a lazy Susan-like couch top immobilization system which rotates about a pivot point was developed. During CT simulation, a patient is immobilized by a Vac-Lok bag within the body frame. The patient is scanned head-first and then feet-first following 180° rotation of the frame. The two scans are imported into the Pinnacle treatment planning system and concatenated to give a full-body CT dataset. Treatment planning matches multiple isocenter volumetric modulated arc (VMAT) fields of the upper body and multiple isocenter parallel-opposed fields of the lower body. VMAT fields of the torso are optimized to satisfy lung dose constraints while achieving a therapeutic dose to the torso. The multiple isocenter VMAT fields are delivered with an indexed couch, followed by body frame rotation about the pivot point to treat the lower body isocenters. The treatment workflow was simulated with a Rando phantom, and the plan was mapped to a solid water slab phantom for point- and film-dose measurements at multiple locations. Results: The treatment plan of 12Gy over 8 fractions achieved 80.2% coverage of the total body volume within ±10% of the prescription dose. The mean lung dose was 8.1 Gy. All ion chamber measurements were within ±1.7% compared to the calculated point doses. All relative film dosimetry showed at least a 98.0% gamma passing rate using a 3mm/3% passing criteria. Conclusion: The proposed patient comfort-oriented TBI technique provides for a uniform dose distribution within the total body while reducing the dose to the lungs.

60 APPLIED LIFE SCIENCES↗

SU-E-T-594: Preliminary Active Scanning Results of KHIMA

Purpose: To verify the design criteria on heavy ion beam irradiation, developing a proto type active scanning system was purposed. The active scanning system consists of scanning magnet, power supplies, beam monitors, energy modulation system, and irradiation control system. Methods: Each components of the active scanning system was designed for carbon beam first. For the fast ramping a laminated yoke was purposed. To measure incoming dose and profile, a plate and strip type of ion chambers were designed. Also, ridge filter and range shifter was manufactured. And, the scanning system was modified to adopt 45 MeV of proton beam because of the absence of carbon ion beam in Korea. The system was installed in a beam line at MC-50, KIRAMS. Also, the irradiation control system and planning software was provided. Results: The scanning experiment was performed by drawing KHIMA logo on GaF film. The logo was scanned by 237 scanning points through time normalized intensity modulation. Also, a grid points scanning was performed to measure the scanning resolution and intensity resolution. Conclusion: A prototype active scanning system was successfully designed and manufactured. Also, an initial experiment to print out a drawing on GaF film through the scanning system was completed. More experiments would be required to specify the system performance.

60 APPLIED LIFE SCIENCES↗

Structure of a Specialized Acyl Carrier Protein Essential for Lipid A Biosynthesis with Very Long-chain Fatty Acids in Open and Closed Conformations

The solution nuclear magnetic resonance (NMR) structures and backbone (15)N dynamics of the specialized acyl carrier protein (ACP), RpAcpXL, from Rhodopseudomonas palustris, in both the apo form and holo form modified by covalent attachment of 4'-phosphopantetheine at S37, are virtually identical, monomeric, and correspond to the closed conformation. The structures have an extra α-helix compared to the archetypical ACP from Escherichia coli, which has four helices, resulting in a larger opening to the hydrophobic cavity. Chemical shift differences between apo- and holo-RpAcpXL indicated some differences in the hinge region between α2 and α3 and in the hydrophobic cavity environment, but corresponding changes in nuclear Overhauser effect cross-peak patterns were not detected. In contrast to the NMR structures, apo-RpAcpXL was observed in an open conformation in crystals that diffracted to 2.0 Å resolution, which resulted from movement of α3. On the basis of the crystal structure, the predicted biological assembly is a homodimer. Although the possible biological significance of dimerization is unknown, there is potential that the resulting large shared hydrophobic cavity could accommodate the very long-chain fatty acid (28-30 carbons) that this specialized ACP is known to synthesize and transfer to lipid A. These structures are the first representatives of the AcpXL family and the first to indicate that dimerization may be important for the function of these specialized ACPs.

Environmental Molecular Sciences Laboratory↗

Structures of Domains I and IV from YbbR are Representative of a Widely Distributed Protein Family

YbbR domains are widespread throughout Eubacteria and are expressed as monomeric units, linked in tandem repeats or cotranslated with other domains. Although the precise role of these domains remains undefined, the location of the multiple YbbR domain-encoding ybbR gene in the Bacillus subtilis glmM operon and its previous identification as a substrate for a surfactin-type phosphopantetheinyl transferase suggests a role in cell growth, division, and virulence. To further characterize the YbbR domains, structures of two of the four domains (I and IV) from the YbbR-like protein of Desulfitobacterium hafniense Y51 were solved by solution nuclear magnetic resonance and X-ray crystallography. The structures show the domains to have nearly identical topologies despite a low amino acid identity (23%). The topology is dominated by {beta}-strands, roughly following a 'figure 8' pattern with some strands coiling around the domain perimeter and others crossing the center. A similar topology is found in the C-terminal domain of two stress-responsive bacterial ribosomal proteins, TL5 and L25. Based on these models, a structurally guided amino acid alignment identifies features of the YbbR domains that are not evident from naive amino acid sequence alignments. A structurally conserved cis-proline (cis-Pro) residue was identified in both domains, though the local structure in the immediate vicinities surrounding this residue differed between the two models. The conservation and location of this cis-Pro, plus anchoring Val residues, suggest this motif may be significant to protein function.

59 BASIC BIOLOGICAL SCIENCES↗

Variation in Mutation Rates Caused by RB69pol Fidelity Mutants Can Be Rationalized on the Basis of Their Kinetic Behavior and Crystal Structures

We have previously observed that stepwise replacement of amino acid residues in the nascent base-pair binding pocket of RB69 DNA polymerase (RB69pol) with Ala or Gly expanded the space in this pocket, resulting in a progressive increase in misincorporation. However, in vivo results with similar RB69pol nascent base-pair binding pocket mutants showed that mutation rates, as determined by the T4 phage rI forward assay and rII reversion assay, were significantly lower for the RB69pol S565G/Y567A double mutant than for the Y567A single mutant, the opposite of what we would have predicted. To investigate the reasons for this unexpected result, we have determined the pre-steady-state kinetic parameters and crystal structures of relevant ternary complexes. We found that the S565G/Y567A mutant generally had greater base selectivity than the Y567A mutant and that the kinetic parameters for dNMP insertion, excision of the 3'-terminal nucleotide residue, and primer extension beyond a mispair differed not only between these two mutants but also between the two highly mutable sequences in the T4 rI complementary strand. Comparison of the crystal structures of these two mutants with correct and incorrect incoming dNTPs provides insight into the unexpected increase in the fidelity of the S565G/Y567A double mutant. Taken together, the kinetic and structural results provide a basis for integrating and interpreting in vivo and in vitro observations.

59 BASIC BIOLOGICAL SCIENCES↗

Vertical Conducting Nanodomains Self-Assembled from Poly(3-hexylthiophene)-Based Diblock Copolymer Thin Films

We have synthesized {pi}-conjugated poly(3-hexyl thiophene)-block-poly(methyl methacrylate) (P3HT-b-PMMA) with a P3HT molecular weight of 11 kDa and a PMMA volume fraction of 0.53, which potentially has several organic electronic applications. Its phase-separation behavior was investigated for various thicknesses cast from organic solvents. When cast onto 300 nm thick SiO{sub 2} dielectrics from toluene, in which the P3HT segments have limited solubility, the P3HT-b-PMMA films consist of nanofibrillar self-assemblies of laterally {pi}-stacked P3HT chains. In contrast, the P3HT segments were found to be highly mobile in chlorobenzene, generating a typical phase-separation morphology consisting of vertically conducting P3HT nanodomains on these dielectrics. As the thickness of the cast films increased, however, the topmost surface becomes covered with {pi}-conjugated nanofibrils that are laterally oriented with respect to the surface. Due to the anisotropic domain orientations of P3HT, top-gate organic field-effect transistors (OFETs) containing the P3HT-b-PMMA films exhibited enhanced electrical performance compared to bottom-gate OFETs.

36 MATERIALS SCIENCE↗