Search NASA⌕ Search

Engineering topics

Lee, Jongmin

Publications and source records attributed to Lee, Jongmin.

At least 19 records

High-performance silicon photonic single-sideband modulators for cold-atom interferometry

The laser system is the most complex component of a light-pulse atom interferometer (LPAI), controlling frequencies and intensities of multiple laser beams to configure quantum gravity and inertial sensors. Its main functions include cold-atom generation, state preparation, state-selective detection, and generating a coherent two-photon process for the light-pulse sequence. To achieve substantial miniaturization and ruggedization, we integrate key laser system functions onto a photonic integrated circuit. Our study focuses on a high-performance silicon photonic suppressed-carrier single-sideband (SC-SSB) modulator at 1560 nanometers, capable of dynamic frequency shifting within the LPAI. By independently controlling radio frequency (RF) channels, we achieve 30-decibel carrier suppression and unprecedented 47.8-decibel sideband suppression at peak conversion efficiency of –6.846 decibels (20.7%). We investigate imbalances in both amplitudes and phases between the RF signals. Using this modulator, we demonstrate cold-atom generation, state-selective detection, and atom interferometer fringes to estimate gravitational acceleration, g ≈ 9.77 ± 0.01 meters per second squared, in a rubidium ( 87 Rb) atom system.

47 OTHER INSTRUMENTATION↗

Proton surface exchange kinetics of perovskite triple conducting thin films for protonic ceramic electrolysis cells: BaPr 0.9 Y 0.1 O 3–δ (BPY) vs. Ba 1–x Co 0.4 Fe 0.4 Zr 0.1 Y 0.1 O 3–δ (BCFZY)

Protonic ceramic electrolysis cells (PCECs) are an attractive green H 2 production technology, given their intermediate-temperature operating range and ability to produce dry H 2 . However, PCECs will benefit from development of more efficient and durable “triple conducting” anodes where steam is split, H incorporated, and oxygen evolved. In this work, we evaluated the kinetics of the steam-splitting/H incorporation reaction on BaPr 0.9 Y 0.1 O 3–δ (BPY) in comparison to the benchmark Ba 1–x Co 0.4 Fe 0.4 Z r0.1 Y 0.1 O 3–δ (BCFZY) composition, replacing most of the transition metal elements (Co, Fe, Zr) with the lanthanide Pr. We prepared geometrically well-defined perovskite BPY and BCFZY thin films by pulsed laser deposition and performed simultaneous optical transmission relaxation and electrical conductivity relaxation measurements at 400–500 °C in 0.21 atm O 2 during switching of the steam partial pressure to isolate and compare their proton surface exchange coefficients (k). The k values of BPY were comparable to those of BCFZY and more stable over time. According to angle-resolved XPS and STEM-EDS mapping of FIB cross-sections, the surface of BPY exhibited Ba enrichment, Pr deficiency, and Si contamination. In contrast, BCFZY exhibited Ba deficiency throughout, no obvious surface segregation, and less Si contamination. The Ba segregation on the BPY film appears to have promoted steam splitting/H incorporation kinetics even though the more basic surface reacted with the acidic environmental SiO x H y . Faster kinetics observed on stoichiometric BCFZY vs. Ba-deficient BCFZY confirmed the benefit of a high A-site Ba concentration. This result contrasts with most work on perovskites applied in solid oxide electrolysis cell anodes, in which A-site segregation is considered deleterious for surface reaction kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Guided cold atom inertial sensors with membrane integrated photonics on atom trap integrated platforms

A guided cold-atom inertial sensor system comprises an atom trap integrated platform, a laser system, a magnetic field system, a control system, and a computing system. The laser system and magnetic field system are adapted to form a magneto-optical trap (MOT) about a suspended waveguide of the atom trap integrated platform made of membrane integrated photonics. After loading cold atoms from a MOT, the photonic atom trap integrated platform generates one-dimensional guided atoms with an evanescent field optical dipole trap (EF-ODT) along the optical waveguide to create guided atomic accelerometers/gyroscopes. Motion of atomic wavepackets in a superposition state is created along the guided atom geometry by way of state-dependent momentum kicks. The light-pulse sequence of guided atom interferometry splits, redirects, and recombines atomic wavepackets, which allows measurement of atom interference fringes sensitive to inertial forces via a probe laser.

Lee, Jongmin↗

Suspended waveguides on membrane and needle structures towards photonic atom trap integrated platforms

An atom trap integrated platform (ATIP) comprises a substrate, a membrane, and a suspended waveguide. The substrate has an opening formed therein. The membrane extends across a portion of the substrate opening. The suspended waveguide is formed on the membrane such that the suspended waveguide extends from a first edge of the substrate to a second edge. A magneto-optical trap (MOT) is formed around the suspended waveguide by emitting a plurality of cooling beams and a repump through the substrate opening. Evanescent fields are established above the suspended waveguide by coupling two trapping beams through the suspended waveguide, which trapping beams are red-detuned and blue-detuned with respect to the resonant optical transition of the atoms. By forming the MOT within the evanescent fields, an evanescent field optical trap (EFOT) is formed.

Lee, Jongmin↗

Passively pumped, polycrystalline ceramic high and ultra-high vacuum chambers

A sealed, passively pumped, polycrystalline ceramic vacuum chamber and method for fabricating the chamber are disclosed. The body of the vacuum chamber is made from a polycrystalline ceramic, for example, alumina. The vacuum chamber includes one or more windows made from a transparent ceramic, for example, sapphire, to accommodate optical access, while remaining amorphous-glass free to minimize or eliminate helium permeation. The vacuum chamber components are joined via laser welding or furnace brazing and the completed chamber is bakeable at temperatures up to 400° C. The vacuum chamber can operate at high or ultra-high vacuum pressures for an extended period through the use of one or more getter-based pumps. The vacuum chamber may include one or more atomic sources depending upon the application.

Walker, Charles A.↗

Compact laser source with frequency modulators generating multiple lines

A compact laser source and a single sideband modulator used therein is disclosed. The compact laser source includes a seed laser and one or more channels, with each channel generating one or more output laser beams having corresponding different wavelengths. The compact laser source can be formed in whole or in part on a single optical motherboard to thereby minimize space and power requirements. By employing the disclosed single sideband modulator, harmonics in the generated output laser beams can be minimized. The compact laser source finds application in an atom interferometer (AI) system, which may be used to measure gravity, acceleration, or rotation of the AI system.

Lentine, Anthony L.↗

Narrow-linewidth laser cooling for rapid production of low-temperature atoms for high data-rate quantum sensing

We present a proof-of-concept demonstration of a narrow linewidth $^{87}$Rb magneto-optical trap (MOT) operating on the narrow linewidth $5S_{1/2}$ → $6P_{3/2}$ transition at 420 nm. We stabilized the absolute frequency of the 420 nm laser to an atomic transition in $^{87}$Rb and demonstrate a MOT using 420 nm light driving the $5S_{1/2}$, $F = 2$ → $6P_{3/2}, F' = 3$ transition. We then use tome-of-flight measurements to characterize the 420 nm MOT temperature, observing a minimum temperature of about $T^{(420)}_{horizontal}$ = 150μK and $T^{(420)}_{vertical}$ = 250μK before the opportunity to perform significant characterization and optimization. Although this temperature is significantly higher then the expected 420 nm Doppler cooling limit ($T_D^{(420)}$ ≈ 34 μK), these are already approaching the Doppler limit of a standard 780 nm MOT ($T_D^{(780)}$ ≈ 146 μK). We believe that with further optimization the Doppler cooling limit of ≈ 34 μK can be achieved. This initial result answers our key research question and demonstrates the viability of applying narrow linewidth laser cooling as a robust technique for future fieldable quantum sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗