Search NASA⌕ Search

Engineering topics

Lee, S. C.

Publications and source records attributed to Lee, S. C..

Negative Differential Resistance (NDR) frequency conversion with gain

The dependence of the I-V characteristic of the negative differential resistance (NDR) devices on the power level and frequency of the rf input signal has been theoretically analyzed with a modified large- and small-signal nonlinear circuit analysis program. The NDR devices we used in this work include both the tunnel diode (without the antisymmetry in the I-V characteristic) and resonant-tunneling devices (with the antisymmetry in the I-V characteristic). Absolute negative conductance can be found from a zero-biased resonant tunneling device when the applied pump power is within a small range. This study verifies the work of Sollner et al. Variable negative conductances at the fundamental and harmonic frequencies can also be obtained from both the unbiased and biased tunnel diodes. The magnitude of the negative conductances can be adjusted by varying the pump amplitude -- a very useful circuit property. However, the voltage range over which the negative conductance occurs moves towards the more positive side of the voltage axis with increasing frequency. Furthermore, the range of the pumping amplitude to obtain negative conductance varies with the parasitics (resistance and capacitance) of the device. The theoretical observation of the dependence of the I-V characteristic of the NDR devices on the power and frequency of the applied pump signal is supported by the experimental results. In addition, novel functions of a NDR device such as self-oscillating frequency multiplier and mixer with gain have been experimentally demonstrated. The unbiased oscillator have also been successfully realized with a NDR device with an antisymmetrical I-V characteristic. Finally, the applications of these device functions will be discussed.

Hwu, R. J.↗

The fault monitoring and diagnosis knowledge-based system for space power systems: AMPERES, phase 1

The objective is to develop a real time fault monitoring and diagnosis knowledge-based system (KBS) for space power systems which can save costly operational manpower and can achieve more reliable space power system operation. The proposed KBS was developed using the Autonomously Managed Power System (AMPS) test facility currently installed at NASA Marshall Space Flight Center (MSFC), but the basic approach taken for this project could be applicable for other space power systems. The proposed KBS is entitled Autonomously Managed Power-System Extendible Real-time Expert System (AMPERES). In Phase 1 the emphasis was put on the design of the overall KBS, the identification of the basic research required, the initial performance of the research, and the development of a prototype KBS. In Phase 2, emphasis is put on the completion of the research initiated in Phase 1, and the enhancement of the prototype KBS developed in Phase 1. This enhancement is intended to achieve a working real time KBS incorporated with the NASA space power system test facilities. Three major research areas were identified and progress was made in each area. These areas are real time data acquisition and its supporting data structure; sensor value validations; development of inference scheme for effective fault monitoring and diagnosis, and its supporting knowledge representation scheme.

Lee, S. C.↗

Data acquisition for a real time fault monitoring and diagnosis knowledge-based system for space power system

The design and implementation of the real-time data acquisition and processing system employed in the AMPERES project is described, including effective data structures for efficient storage and flexible manipulation of the data by the knowledge-based system (KBS), the interprocess communication mechanism required between the data acquisition system and the KBS, and the appropriate data acquisition protocols for collecting data from the sensors. Sensor data are categorized as critical or noncritical data on the basis of the inherent frequencies of the signals and the diagnostic requirements reflected in their values. The critical data set contains 30 analog values and 42 digital values and is collected every 10 ms. The noncritical data set contains 240 analog values and is collected every second. The collected critical and noncritical data are stored in separate circular buffers. Buffers are created in shared memory to enable other processes, i.e., the fault monitoring and diagnosis process and the user interface process, to freely access the data sets.

Wilhite, Larry D.↗

Development of a component centered fault monitoring and diagnosis knowledge based system for space power system

The overall approach currently being taken in the development of AMPERES (Autonomously Managed Power System Extendable Real-time Expert System), a knowledge-based expert system for fault monitoring and diagnosis of space power systems, is discussed. The system architecture, knowledge representation, and fault monitoring and diagnosis strategy are examined. A 'component-centered' approach developed in this project is described. Critical issues requiring further study are identified.

Lee, S. C.↗

A fast viscous correction method for full-potential transonic wing analysis

An analysis of the transonic flowfield around a three-dimensional wing is carried out using a strip method. Attention is given to the boundary layer growth in the streamwise direction. A viscous correction technique is defined for the TWING code for solving the full potential equations. A viscous ramp at the base of a shock is superimposed on the boundary layer displacement thickness generated by an integral boundary layer method. A relationship is then obtained between the effective displacement thickness and a vertical component of the surface velocity, a transpirational boundary condition. The viscous correction is found to be unnecessary in weak shock conditions but gives a better shock position and pressure distribution in a strong shock condition when compared with data from an ONERA M6 airfoil and the Hinson and Burdges (1980) Wing A.

Lee, S. C.↗

A fast viscous correction method for unsteady transonic flow about airfoils

This study modified the inviscid, small-disturbances, unsteady, transonic code, LTRAN2, so that the viscous effect could be considered for the purpose of improving the code's accuracy without substantially increasing the computational time. By using a conventional integral boundary layer method to determine the displacement thickness and an empirical model of viscous wedge to simulate the suddenly thickened boundary layer behind a shock, it resulted in better agreement with experimental data for both the shock position and the pressure coefficient. Aerodynamic performances were calculated for two supercritical airfoils. When the unsteady procedure was used to obtain steady state results as the initial condition, the unsteady viscous solution for the RAE 2822 airfoil required 100.5% of the computational time of the inviscid solution. When an iterative scheme was used to obtain the steady state results as the initial condition, the unsteady viscous solution for the NLR 7301 airfoil required 88% of the computational time of the inviscid solution.

Lee, S. C.↗

Viscous effect on airfoils for unsteady transonic flows

The viscous effect on aerodynamic performance of an arbitrary airfoil executing low frequency maneuvers during transonic flight was investigated. The small disturbance code, LTRAN2, was modified by using a conventional integral method, BLAYER, for the boundary layer and an empirical relation, viscous wedge, for simulating the suddenly thickened boundary layer behind the shock. Before the shock, only the boundary layer displacement thickness was evaluated. After the shock, the empirical wedge thickness was superimposed on the boundary layer thickness along the surface as well as in the wake region. The pressure coefficients were calculated for both steady and unsteady states. The viscous solution takes fewer iterations to obtain the converged steady state solution. Comparisons made with experimental data and the inviscid solution show that the viscous solution agrees better with the experimental data with about the same (or slightly less) amount of computational time.

Lee, S. C.↗

Numerical simulation of steady transonic flow about airfoils

A computer code has been developed that couples a fast transonic full-potential AF2 solver with both an efficient integral boundary-layer method and a viscous wedge approximation of the shock/boundary-layer interaction. The efficiency of the coupled analysis methods and the method of coupling has resulted in a uniquely efficient analysis tool. The airfoil geometry is modified by the displacement thickness before the shock and the displacement thickness plus the viscous wedge thickness after the shock by considering the viscous effects as an equivalent transpiration boundary condition. The flow about conventional and supercritical airfoils under moderately strong shock situations has been calculated. Comparisons with experimental data indicate that this viscous correction method has improved the accuracy of the full-potential analysis. Furthermore, the computer time required to obtain a converged solution has been reduced.

Lee, S. C.↗