Search NASA⌕ Search

Engineering topics

Lee, Sang Heon

Publications and source records attributed to Lee, Sang Heon.

Ultra-Sharp Nanowire Arrays Natively Permeate, Record, and Stimulate Intracellular Activity in Neuronal and Cardiac Networks

Intracellular access with high spatiotemporal resolution can enhance the understanding of how neurons or cardiomyocytes regulate and orchestrate network activity and how this activity can be affected with pharmacology or other interventional modalities. Nanoscale devices often employ electroporation to transiently permeate the cell membrane and record intracellular potentials, which tend to decrease rapidly with time. Here, one reports innovative scalable, vertical, ultrasharp nanowire arrays that are individually addressable to enable long-term, native recordings of intracellular potentials. One reports electrophysiological recordings that are indicative of intracellular access from 3D tissue-like networks of neurons and cardiomyocytes across recording days and that do not decrease to extracellular amplitudes for the duration of the recording of several minutes. The findings are validated with cross-sectional microscopy, pharmacology, and electrical interventions. The experiments and simulations demonstrate that the individual electrical addressability of nanowires is necessary for high-fidelity intracellular electrophysiological recordings. This work advances the understanding of and control over high-quality multichannel intracellular recordings and paves the way toward predictive, high-throughput, and low-cost electrophysiological drug screening platforms.

36 MATERIALS SCIENCE↗

High precision deflection measurement of microcantilever in an optical pickup head based atomic force microscopy

This paper presents the methodology to measure the precise deflection of microcantilever in an optical pickup head based atomic force microscopy. In this paper, three types of calibration methods have been proposed: full linearization, sectioned linearization, and the method based on astigmatism. In addition, the probe heads for easy calibration of optical pickup head and fast replacement of optical pickup head have been developed. The performances of each method have been compared through a set of experiments and constant height mode operation which was not possible in the optical pickup head based atomic force microscopy has been carried out successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Large rotation measurement using half shaded square patterns

As the manufacturing technology ranging from micrometer to nanometer scale requires more planar motion devices, the demand for sensor measuring the planar motion is increasing. However, the previous sensors measuring the planar motion had a drawback in the measurement of rotation, especially regarding yaw angle. In this article, we present a novel method to measure large yaw angle with the planar position sensor based on the half shaded square patterns. The measuring range of the yaw angle is restricted to 45 deg. in this article, but it can be expanded to as much as 360 deg. with an improvement of the algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗