Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X–Y–U)-strip anode readout

The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X--Y--U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using simple standard PCB fabrication techniques. Capacitive-sharing (X--Y--U)-strip readout allows simultaneous measurement of the Cartesian coordinates x and y of the position of the particles together with a third coordinate u along the diagonal axis in a single readout PCB. This provides a powerful tool to address multiple-hit ambiguity and enable pattern recognition capabilities in moderate particle flux environment of collider or fixed target experiments in high energy physics HEP) and nuclear physics (NP). We present in this paper the performance of a 10 cm × 10 cm triple-GEM detector with capacitive-sharing (X--Y--U)-strip anode readout. Spatial resolutions of the order of $\sigma_{x}^{res}$ = 71.6 $\pm$ 0.8 $\mu$m for X-strips, $\sigma_{y}^{res}$ = 56.2 $\pm$ 0.9 $\mu$m for Y-strips and $\sigma_{u}^{res}$ = 75.2 $\pm$ 0.9 $\mu$m for U-strips have been obtained at a beam test at Thomas Jefferson National Accelerator Facility (Jefferson Lab). Modifications of the readout design of future prototypes to improve the spatial resolution and challenges in scaling to large-area MPGDs are discussed.

(X-Y-U) strip↗

Method and apparatus to obtain limited angle tomographic images from stationary gamma cameras

A nuclear imaging system and method for performing three-dimensional imaging of anatomical structures. The system and method includes two or more gamma ray detectors each used in combination with a variable-slant hole collimator. The detectors are positioned in close proximity to, or in contact with, the structure being imaged. The detectors remain in a stationary position during the data collection process. An imaging or reconstruction method is then used to reconstruct a three-dimensional image from the data derived from the detectors.

Kross, Brian J.↗

Apparatus and method for variable angle slant hole collimator

A variable angle slant hole (VASH) collimator for providing collimation of high energy photons such as gamma rays during radiological imaging of humans. The VASH collimator includes a stack of multiple collimator leaves and a means of quickly aligning each leaf to provide various projection angles. Rather than rotate the detector around the subject, the VASH collimator enables the detector to remain stationary while the projection angle of the collimator is varied for tomographic acquisition. High collimator efficiency is achieved by maintaining the leaves in accurate alignment through the various projection angles. Individual leaves include unique angled cuts to maintain a precise target collimation angle. Matching wedge blocks driven by two actuators with twin-lead screws accurately position each leaf in the stack resulting in the precise target collimation angle. A computer interface with the actuators enables precise control of the projection angle of the collimator.

47 OTHER INSTRUMENTATION↗

A Prototype Gamma Tomosynthesis System for Molecular Breast Imaging

We are developing an improved gamma camera for molecular breast imaging (MBI) that allows tomographic imaging and improved signal-to-noise over conventional planar methods. We have built a novel gamma camera for MBI that utilizes limited angle tomography, similar to x-ray tomosynthesis, to generate images with depth information and improved signal-to-noise. A unique feature of the gamma tomosynthesis system is a variable-angle slant hole (VASH) collimator. This collimator allows the camera to remain flush against the compression paddle during the tomographic acquisition, which achieves high spatial resolution and simplified detector motion. We constructed a VASH collimator from a stack of tungsten sheets, each sheet containing a matrix of holes created by photo-etching. With the holes of the sheets aligned, a parallel-hole collimator is created; shearing the sheets creates a variable angle slant hole collimator. The shearing is controlled by a motorized mechanism. The collimator was mounted on a commercial MBI camera and projection data were acquired of a set of capillary tube line sources over a 50° range of angles. The projection data were reconstructed using the iterative MLEM method. Results demonstrated the ability of the system to resolve in the depth dimension, and spatial resolution matched expected values. We conclude that the proposed gamma tomosynthesis system has the potential to provide improved signal-to-noise over conventional MBI methods and allow a reduction in the administered radioactivity and patient dose.

Gilland, David↗

CDK2 and mTOR are direct molecular targets of isoangustone A in the suppression of human prostate cancer cell growth

Licorice extract which is used as a natural sweetener has been shown to possess inhibitory effects against prostate cancer, but the mechanisms responsible are poorly understood. Here, we report a compound, isoangustone A (IAA) in licorice that potently suppresses the growth of aggressive prostate cancer and sought to clarify its mechanism of action. We analyzed its inhibitory effects on the growth of PTEN-deleted human prostate cancer cells, in vitro and in vivo. Administration of IAA significantly attenuated the growth of prostate cancer cell cultures and xenograft tumors. These effects were found to be attributable to inhibition of the G1/S phase cell cycle transition and the accumulation of p27{sup kip1}. The elevated p27{sup kip1} expression levels were concurrent with the decrease of its phosphorylation at threonine 187 through suppression of CDK2 kinase activity and the reduced phosphorylation of Akt at Serine 473 by diminishing the kinase activity of the mammalian target of rapamycin (mTOR). Further analysis using recombinant proteins and immunoprecipitated cell lysates determined that IAA exerts suppressive effects against CDK2 and mTOR kinase activity by direct binding with both proteins. These findings suggested that the licorice compound IAA is a potent molecular inhibitor of CDK2 and mTOR, with strong implications for the treatment of prostate cancer. Thus, licorice-derived extracts with high IAA content warrant further clinical investigation for nutritional sources for prostate cancer patients. - Highlights: • Isoangustone A suppresses growth of PC3 and LNCaP prostate cancer cells. • Administration of isoangustone A inhibits tumor growth in mice. • Treatment of isoangustone A induces cell cycle arrest and accumulation of p27{sup kip1}. • Isoangustone A inhibits CDK2 and mTOR activity. • Isoangustone A directly binds with CDK2 and mTOR complex in prostate cancer cells.