Search NASA⌕ Search

Engineering topics

Lehnen, M.

Publications and source records attributed to Lehnen, M..

Implementation of low temperature spectrometers for the JET high resolution Thomson scattering diagnostic for disruption plasma measurements

This work presents a system upgrade of the High Resolution Thomson Scattering (HRTS) diagnostic on JET that allows it to measure low temperature (1–500 eV) plasma pre- and post-Thermal quench (TQ), which would help us further understand the Shattered Pellet Injection (SPI) physics. The upgrade was done by connecting optic fibers from the original HRTS system to four spectrometers specialized in measuring low temperature plasmas. The upgraded system allows for the measurement of low temperature plasma at up to 12 spatial points, which can be flexibly distributed throughout the JET outer midplane profile during the dedicated SPI experiments. In other JET experiments, four previously unused groups of fibers were used to measure the central plasma to provide disruption data without changing the standard HRTS system. The low temperature Thomson scattering system was installed, commissioned, and cross-calibrated against the standard HRTS diagnostic in a calibration pulse. The system worked reliably during the JET experiments and provided electron density and temperature profiles for pre- and post-TQ low temperature plasmas in the SPI campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modifications to the JET Shattered Pellet Injector to Optimize Disruption Mitigation Experiments for Supporting ITER’s DMS Design

Shattered pellet injection (SPI) experiments on Joint European Torus (JET) are an important element in determining the physics basis for mitigating disruptions in ITER. Here, the initial design of the JET SPI system included three barrels to produce pellets with diameters of 4.5, 8.1, and 12.5 mm. The variability of the pellet speed by operating with and without a mechanical punch was limited and led to poor pellet integrity, so the mechanical punch was removed. Fragment size distribution is a function of pellet speed and the desire to change the resulting fragment size distribution was not originally a requirement. After the first set of SPI experiments on JET, different pellet sizes were considered to enable dual injection experiments with identical pellet diameters. It was also determined that speed control is necessary to improve experimental repeatability and to determine how the fragment size distribution impacts mitigation performance. Two barrels were fabricated to form pellets of 10 mm diameter and a third to form an 8.1 mm diameter pellet. New propellant valves were also fabricated and characterized to improve repeatability and overall performance. To have fine control of pellet speed, inserts to reduce the breech volume were fabricated and installed. Laboratory testing was conducted to ensure pellet release and provide a comparison of propellant gas delivered versus pellet speeds for a range of pellet types and mixtures. This article will also discuss how lessons learned from the JET SPI modifications can be applied to other SPI systems, such as the ITER SPI system, as controlling pellet release with the least amount of propellant gas is essential for optimal SPI effectiveness.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reassessing energy deposition for the ITER 5 MA vertical displacement event with an improved DINA model

The beryllium (Be) main chamber wall interaction during a 5 MA/1.8 T upward, unmitigated VDE scenario, first analysed in [J. Coburn et al., Phys. Scr. T171 (2020) 014076] for ITER, has been re-evaluated using the latest energy deposition analysis software. Updates to the DINA disruption model are summarized, including an improved numerical convergence for the 0D power balance, limitations on the safety factor within the plasma core, and the choice to maintain a constant plasma +halo poloidal cross-section. Such updates result in a broad halo region and higher radiated power fractions compared to previous models. The new scenario lasts for ~75 ms and deposits ~29 MJ of energy, with the radial distribution of parallel heat flux q‖(r)resembling an exponential falloff with an effective λ_q=75-198 mm. A maximum halo width w_h of 0.52 m at the outboard midplane is observed. SMITER field line tracing and energy deposition simulations calculate a q_{⊥,max} of ~83 MW/m^2 on the upper first wall panels (FWP). Heat transfer calculations with the MEMOS-U code show that the FWP surface temperature reaches ~1000 K, well below the Be melt threshold. Variations of this 5 MA scenario with Be im-purity densities from 0 to 3∙10^19 m^-3 also remain below the melt threshold despite differences in energy deposition and duration. These results are in contrast to the early study which predicted melt damage to the first wall [J. Coburn et al., Phys. Scr. T171 (2020) 014076], and emphasize the importance of accurate models for the halo width w_h and the heat flux distribution q‖(r)within that halo width. The 2020 halo model in DINA has been compared with halo current experiments on COMPASS, JET, and Alcator C-Mod, and the preliminary results build confidence in the broad halo width predictions. Results for the 5 MA VDE are compared with those for a 15 MA equivalent, generated using the new DINA model. At the higher current, significant melting of the upper FWP is to be expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Physics of runaway electrons with shattered pellet injection at JET

Runaway electrons (REs) created during tokamak disruptions pose a threat to the reliable operation of future larger machines. Experiments using shattered pellet injection (SPI) have been carried out at the JET tokamak to investigate ways to prevent their generation or suppress them if avoidance is not sufficient. Avoidance is possible if the SPI contains a sufficiently low fraction of high-Z material, or if it is fired early in advance of a disruption prone to runaway generation. These results are consistent with previous similar findings obtained with Massive Gas Injection. Suppression of an already accelerated beam is not efficient using High-Z material, but deuterium leads to harmless terminations without heat loads. This effect is due to the combination of a large magnetohydrodynamic instability scattering REs on a large area and the absence of runaway regeneration during the subsequent current collapse thanks to the flushing of high-Z impurities from the runaway companion plasma. This effect also works in situations where the runaway beam moves upwards and undergoes scraping-off on the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disruption thermal load mitigation with shattered pellet injection on the Joint European Torus (JET)

Disruption mitigation remains a critical, unresolved challenge for ITER. To aid in addressing this challenge, a shattered pellet injection (SPI) system was installed on JET and experiments conducted at a range of thermal energy fractions and stored energies in excess of 7 MJ. The primary goals of these experiments were to investigate the efficacy of the SPI on JET and the ability of the plasma to assimilate multiple pellets. Single pellet injections produced a saturation in total radiated energy (Wrad) with increasing injected neon content, suggesting total radiation of stored thermal energy. Further increases in injected neon quantities resulted in reduced cooling times and current quench (CQ) durations, indicating higher impurity assimilation. No significant variation in CQ duration or W rad was observed when varying the deuterium content at fixed neon quantities. Additionally, higher assimilation, inferred by shorter CQ durations, was measured when a mechanical punch was used to launch the pellets and this was attributed to a lower pellet velocity leading to higher solid content in the pellet plume and larger fragments penetrating deeper into the plasma. Radiation asymmetries averaged over the cooling time were inferred from Emis3D and ranged from 1.6 to 1.9. Asymmetries averaged over the entire disruption sequence were found to increase at higher thermal energy fractions. The radiated energy fractions decreased with increasing thermal energy fractions but this trend was eliminated when toroidal asymmetries were accounted for with Emis3D. Pure deuterium pellets were able to produce cooling times of up to 75 ms with a gradual loss in thermal stored energy of up to 80%. Experiments with multiple pellet injection indicated W rad can be increased through pellet superposition and density can be increased with an additional D2 injection without a reduction in W rad . KPRAD modelling accurately reproduced the cooling times and the CQ duration at high thermal energies. Assimilation estimates from KPRAD indicated CQ rates scale strongly whilst W rad scales weakly and saturates with assimilated neon content. Comparable W rad can be achieved with lower assimilated neon quantities as longer cooling times are attained. Thus reduced neon content can be preferential in a thermal load mitigation scheme as it may reduce radiation asymmetries and prevent flash melting.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-device study of temporal characteristics of magnetohydrodynamic modes initiating disruptions

Disruptions in tokamaks are often preceded by magnetohydrodynamic (MHD) instabilities that can rotate or become locked to the wall. Measurements from magnetic diagnostics in the presence of MHD mode precursors to disruptions can yield potentially valuable input to the plasma control system, with a view to disruption avoidance, prediction and mitigation. This report presents an exploratory analysis of the growth of MHD modes and corresponding time scales on the basis of magnetic measurements in multiple tokamaks. To this end, a database was compiled using disruptive discharges from COMPASS, ASDEX Upgrade, DIII-D and JET, manually classified according to disruption root cause, and characterized by a great diversity of operational conditions and mode dynamics. The typical time during which a mode can be detected using saddle coils and the duration of the locked mode phase in the database both extend over several orders of magnitude, but generally the time scales increase with plasma size. Several additional factors are discussed that can influence these durations, including the disruption root cause. A scaling law for the locked phase duration was estimated, yielding predictions toward ITER of the order of hundreds of milliseconds or even seconds. In addition, a scaling law for the mode amplitude at the disruption onset, proposed earlier by de Vries et al. (2016), is applied to the database, and its predictive capabilities are assessed. Despite significant uncertainty on the predictions from both scaling laws, encouraging trends are observed of the fraction of disruptions that may be detected with sufficient warning time to allow mitigation or even avoidance, based solely on observations of MHD mode dynamics. When combined with similar analysis of measurements from diagnostics that are sensitive to other disruption precursors, our analysis methods and results may contribute to the reliability, robustness and generalization of disruption warning schemes for ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗