Lehtinen, A. M.

Publications and source records attributed to Lehtinen, A. M..

Spacecraft active thermal control subsystem design and operation considerations

Future spacecraft missions will be characterized by high electrical power requiring active thermal control subsystems for acquisition, transport, and rejection of waste heat. These systems will be designed to operate with minimum maintenance for up to 10 years, with widely varying externally-imposed environments, as well as the spacecraft waste heat rejection loads. This paper presents the design considerations and idealized performance analysis of a typical thermal control subsystem with emphasis on the temperature control aspects during off-design operation. The selected thermal management subsystem is a cooling loop for a 75-kWe fuel cell subsystem, consisting of a fuel cell heat exchanger, thermal storage, pumps, and radiator. Both pumped-liquid transport and two-phase (liquid/vapor) transport options are presented with examination of similarities and differences of the control requirements for these representative thermal control options.

Sadunas, J. A.↗

Thermal storage analysis for large manned space platforms

High electrical power and waste heat rejection is projected for future manned low earth orbit space platforms, such as Space Station. The high heat rejection, optical coating degradation, long operating life with minimum maintenance requirements pose a challenging thermal management design problem. System optimization, with respect to radiator area and weight, indicate the requirement for thermal storage. This paper examines the thermal storage benefits, determines the characteristics as applied to different TMS concepts (e.g., centralized, decentralized), and examines the similarities and differences of thermal storage integration with single-phase and two-phase systems for a study baseline 75 kWe low earth orbit platform.

Lehtinen, A. M.↗

Fabrication and test of a variable conductance heat pipe

A variable conductance heat pipe (VCHP) with feedback control was fabricated with a reservoir-condenser volume ratio of 10 and an axially grooved action section. Tests of the heat transport capability were greater than or equal to the analytical predictions for the no gas case. When gas was added, the pipe performance degraded by 18% at zero tilt as was expected. The placement of the reservoir heater and the test fixture cooling fins are believed to have caused a superheated vapor condition in the reservoir. Erroneously high reservoir temperature indications resulted from this condition. The observed temperature gradients in the reservoir lend support to this theory. The net result was higher than predicted reservoir temperatures. Also, significant increases in minimum heat load resulted for controller set point temperatures higher than 0 C. At 30 C, control within the tolerance band was maintained, but high reservoir heater power was required. Analyses showed that control is not possible for reasonably low reservoir heater power. This is supported by the observation of a significant reservoir heat leak through the condenser.

Lehtinen, A. M.↗