Search NASASearch

Engineering topics

Leidecker, Henning

Publications and source records attributed to Leidecker, Henning.

25 records · Page 2

Cable Bundle Wire Derating

The allowable operating currents of electrical wiring when used in the space vacuum environment is predominantly determined by the maximum operating temperature of the wire insulation. For Kapton insulated wire this value is 200 C. Guidelines provided in the Goddard Space Flight Center (GSFC) Preferred Parts List (PPL) limit the operating current of wire within vacuum to ensure the maximum insulation temperature is not exceeded. For 20 AWG wire, these operating parameters are: (1) 3.7 amps per wire; (2) bundle of 15 or more wires; (3) 70 C environment: and (4) vacuum of 10(exp -5) torr or less. To determine the behavior and temperature of electrical wire at different operating conditions, a thermal vacuum test was performed on a representative electrical harness of the Hubble Space Telescope (HST) power distribution system. This paper describes the test and the results.

Lundquist, Ray A.

Elastic Moduli and Damping of Vibrational Modes of Aluminum/Silicon Carbide Composite Beams

Elastic and shear moduli were determined for two aluminum matrix composites containing 20 and 40 volume percent discontinuous silicon carbide, respectively, using transverse, longitudinal, and torsional vibrational modes of specimens prepared as thin beams. These moduli are consistent with those determined from stress-strain measurements. The damping factors for these modes were also determined. Thermal properties are used to show that part of the damping of transverse modes is caused by the transverse thermal currents discussed by C. Zener (thermo-elastic damping); this damping is frequency-dependent with a maximum damping factor of approximately 0.002. The remaining damping is frequency-independent, and has roughly similar values in transverse, longitudinal, and torsional modes: approximately 0.0001.

Leidecker, Henning

Scanning For Hotspots In Lamp Filaments

Scanning photometer designed for use in investigation of failures of incandescent lamp filaments. Maps brightness as function of position along each filament to identify bright (hot) spots, occurring at notches and signifying incipient breaks or rewelds. Also used to measure nonuniformity in outputs of such linear devices as light-emitting diodes, and to measure diffraction patterns of lenses.

Powers, Charles E.

Measuring Thermal Diffusivity Of A High-Tc Superconductor

Technique for measuring thermal diffusivity of superconductor of high critical temperature based on Angstrom's temperature-wave method. Peltier junction generates temperature oscillations, which propagate with attenuation up specimen. Thermal diffusivity of specimen calculated from distance between thermocouples and amplitudes and phases of oscillatory components of thermocouple readings.

Powers, Charles E.

Nonintrusive Measurement Of Temperature Of LED Junction

Temperature inferred from spectrum of emitted light. Method of determining temperature of junction based on two relevant characteristics of LED. Gap between valence and conduction electron-energy bands in LED material decreases with increasing temperature, causing wavelength of emitted photon to increase with temperature. Other, as temperature increases, non-radiative processes dissipate more of input electrical energy as heat and less as photons in band-gap wavelenth region; optical and quantum efficiencies decrease with increasing temperature. In principal, either characteristic alone used to determine temperature. However, desirable to use both to obtain indication of uncertainty.

Leidecker, Henning

Chaotic rhythms of a dripping faucet

An experiment was conducted which showed that a leaky faucet can offer valuable insights on predicting fluid flow. In this experiment, a flow control and drop detector were connected to the printer port of an IBM PC, which computed and saved the time intervals using a program for droptime compiled with Turbo C. It is noted that the time intervals change from periodic to doubly periodic as the flow rate is increased and then to various forms of chaos, interrupted by windows of periodicity. A number of two- and three-dimensional plots are displayed and discussed. Attention is focused on one of the simpler plots which is approximately parabolic, where each successive time interval is a quadratic function of the preceding interval, with a steepness which depends upon the flow rate. It is shown that a single past analog can predict a dripping faucet with reasonable accuracy 7-10 drops ahead. While such methods are more difficult to apply in higher-dimensional systems, this experiment aids in understanding how fluid flow may be predicted even under conditions of unstable flows caused by increase in velocity.

Cahalan, Robert F.

The crush of new earth science data knocking at our door

The reasons for collecting massive amounts of earth science data in the Earth Observing System (EOS) Project are discussed. A processing hierarchy for handling the data is described, and the prospects for adequate throughput and storage for operational data analysis in the EOS era are addressed. Needs for successful exploratory data analysis are examined, and the policy issues implicated by the large stream of EOS data are considered.

Kahn, Ralph