Search NASA⌕ Search

Engineering topics

Leigh, Larry

Publications and source records attributed to Leigh, Larry.

Assessing the Calibration Differences in the Reflective Solar Bands of Terra MODIS and Landsat-7 Enhanced Thematic Mapper Plus

Long-term data records obtained from Earth observing sensors depend not only onthe calibration accuracy of individual sensors but also on the consistency across instruments andplatforms. Hence, sensor calibration intercomparison plays a vital role for a better understandingof various science products. The Moderate Resolution Imaging Spectroradiometer (MODIS)and enhanced thematic mapper plus (ETM+) on the Terra and Landsat 7 platforms have operatedsuccessfully since their launch, collecting measurements in the reflective solar and infrared partsof the spectrum. Terra MODIS has employed a reflectance-based calibration since beginning itsmission. In the case of ETM+, a radiance-based calibration was employed until recent years,when a reflectance-based calibration was introduced. Being in the AM constellation with lessthan 30 min difference in overpass times, near-simultaneous Earth scene measurements can beeffectively used to assess the calibration differences between the spectrally matching bands ofthese two instruments. The pseudoinvariant calibration sites (PICS) in the North African desertare widely used for on-orbit calibration and validation of satellite sensors. Four PICS from thisregion have been employed to assess the multitemporal reflectance differences. Correction forbidirectional reflectance, spectral response function mismatch, and impacts of atmosphericwater-vapor have been incorporated to provide an assessment of the long-term stability ofeach spectral band and reflectance differences amongst them. Results indicate that the spectralbands of both instruments show a long-term stability to within 2% from 2000 to 2017. Thetop-of-atmosphere reflectances between the two instruments postcorrection agree to within 4%.Also included in this paper is a detailed discussion of various parameters contributing to theuncertainties of this cross-calibration. The techniques presented in this paper can be furtherextended to perform similar intercomparison between Landsat 8 Operational Land Imager, AquaMODIS, and Suomi-NPP VIIRS.

Angal, Amit↗

Overview of the 2015 Algodones Sand Dunes Field Campaign to Support Sensor Intercalibration

Several sites from around the world are being used operationally and are suitable for vicarious calibration of space-borne imaging platforms. However, due to the proximity of these sites (e.g., Libya 4), a rigorous characterization of the landscape is not feasible, limiting their utility for sensor intercalibration efforts. Due to its accessibility and similarities to Libya 4, the Algodones Sand Dunes System in California, USA, was identified as a potentially attractive intercalibration site for space-borne, reflective instruments such as Landsat. In March 2015, a 4-day field campaign was conducted to develop an initial characterization of Algodones with a primary goal of assessing its intercalibration potential. Five organizations from the US and Canada collaborated to collect both active and passive airborne image data, spatial and temporal measurements of spectral bidirectional reflectance distribution function, and in-situ sand samples from several locations across the Algodones system. The collection activities conducted to support the campaign goal is summarized, including a summary of all instrumentation used, the data collected, and the experiments performed in an effort to characterize the Algodones site.

McCorkel, Joel↗

Recent Surface Reflectance Measurement Campaigns with Emphasis on Best Practices, SI Traceability and Uncertainty Estimation

A significant problem facing the optical satellite calibration community is limited knowledge of the uncertainties associated with fundamental measurements, such as surface reflectance, used to derive satellite radiometric calibration estimates. In addition, it is difficult to compare the capabilities of calibration teams around the globe, which leads to differences in the estimated calibration of optical satellite sensors. This paper reports on two recent field campaigns that were designed to isolate common uncertainties within and across calibration groups, particularly with respect to ground-based surface reflectance measurements. Initial results from these efforts suggest the uncertainties can be as low as 1.5% to 2.5%. In addition, methods for improving the cross-comparison of calibration teams are suggested that can potentially reduce the differences in the calibration estimates of optical satellite sensors.

reflectance measurements↗

AWiFS Radiometric Assessment

An Advanced Wide Field Sensor (AWiFS) radiometric assessment using a standard analysis technique is presented.

Aaron, David↗

Initial Radiometric Calibration of the AWiFS using Vicarious Calibration Techniques

NASA SSC maintains four ASD FieldSpec FR spectroradiometers: 1) Laboratory transfer radiometers; 2) Ground surface reflectance for V&V field collection activities. Radiometric Calibration consists of a NIST-calibrated integrating sphere which serves as a source with known spectral radiance. Spectral Calibration consists of a laser and pen lamp illumination of integrating sphere. Environmental Testing includes temperature stability tests performed in environmental chamber.

Pagnutti, Mary↗

Dynamic Characterization of an Inflatable Concentrator for Solar Thermal Propulsion

An inflatable structural system that is a technology demonstrator for solar thermal propulsion and other applications is characterized for structural dynamic behavior both experimentally and computationally. The inflatable structure is a pressurized assembly developed for use in orbit to support a Fresnel lens or inflatable lenticular element for focusing sunlight into a solar thermal rocket engine. When the engine temperature reaches a pre-set level, the propellant is injected into the engine, absorbs heat from an exchanger, and is expanded through the nozzle to produce thrust. The inflatable structure is a passively adaptive system in that a regulator and relief valve are utilized to maintain pressure within design limits during the full range of orbital conditions. Modeling and test activities are complicated by the fact that the polyimide film material used for construction of the inflatable is nonlinear, with modulus varying as a function of frequency, temperature, and level of excitation. Modal vibration testing and finite element modeling are described in detail in this paper. The test database is used for validation and modification of the model. This work is highly significant because of the current interest in inflatable structures for space application, and because of the difficulty in accurately modeling such systems.

Leigh, Larry↗