Emission Lines of Fe xiv, Fe xv, and Fe xvi in the Extreme Ultraviolet Region 40–100 Å

We report on emission spectra of iron in the extreme ultraviolet recorded at an electron density of ~10 11 cm -3 on the Lawrence Livermore electron beam ion trap facility. We present a summary of the observed emission lines, including wavelengths and emission intensities, and present spectra of pure Fe xiv through Fe xvi emission derived from our measurements in the 40–100 Å wavelength range. We show that spectral models, especially the current version of CHIANTI v10.0, describe the M-shell emission from these three charge states of iron reasonably well, and we are able to verify several transitions in CHIANTI for the first time.

74 ATOMIC AND MOLECULAR PHYSICS↗

Temperature Measurements Using the Dielectronic Satellite Lines of Fe xvii

The coronal temperature of Capella and Procyon has been derived from the spectral emission of Fe XVII observed in high resolution with Chandra's High Energy Transmission Grating Spectrometer. The measurement makes use of well resolved dielectronic satellite features with a spectator electron in the n = 4 shell. This method does not require a priori knowledge of the ionization equilibrium or of the elemental abundances. We find the temperature of Fe XVII emission is ${264}_{-51}^{+142}$ eV for Procyon and ${514}_{-25}^{+27}$ eV for Capella, i.e., 3.1 and 6.0 MK, respectively. As a result, the Procyon measurement is based on three X-rays observed in the dielectronic satellite feature, which illustrates the power of the method even for low-signal observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma Measurements of the Fe xvii L-shell Emission and Blending with F viii and F ix

Here, we measured the L-shell emission spectrum of Fe xvii in a low-density, low-gradient magnetically confined laboratory plasma that contains predominately C, O, Fe, and Ni as trace elements and found excellent agreement with the relative spectral emission obtained in solar and astrophysical observations. However, we obtained spectra that appear to have an usually large $1{s}^{2}2{s}^{2}2{p}_{1/2}^{5}3{d}_{3/2}\to 1{s}^{2}2{s}^{2}2{p}^{6}$ Fe xvii resonance transition, which is commonly labeled $3C$, from hot plasmas that also contain fluorine. The wavelength of the Lyα feature of F ix is coincident with the wavelength of the Fe xvii line $3C$ within one part in 538, and its flux, therefore, enhances the Fe xvii resonance line. Moreover, the resonance and forbidden lines of F viii are close to the $3s\to 2p$ transitions in Fe xvii and may further alter the inferred apparent Fe xvii line ratios, particularly in spectrometers with moderate spectral resolution. The enhanced emission of line $3C$ can thus serve as a new spectral diagnostic for the detection of fluorine in astrophysical plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of L-shell transitions in M-shell ions in the laboratory and identification in stellar coronae

Based on laboratory data from the Lawrence Livermore EBIT-I electron beam ion trap and calculations using the relativistic multi-reference Møller-Plesset (MRMP) perturbation theory approach, we identify L-shell transitions of M-shell iron ions in emission spectra of the nearby stars Capella and Procyon. In conclusion, these lines are weaker than the well known, prominent lines from Fe XVII. However, they need to be taken into account when modeling the spectra, especially of cool stars.

74 ATOMIC AND MOLECULAR PHYSICS↗

Responsivity calibration of the LoWEUS spectrometer

We performed an in situ calibration of the relative responsivity function of the Long-Wavelength Extreme Ultraviolet Spectrometer (LoWEUS), while operating on the Lithium Tokamak Experiment (LTX) at Princeton Plasma Physics Laboratory. The calibration was accomplished by measuring oxygen lines, which are typically present in LTX plasmas. The measured spectral line intensities of each oxygen charge state were then compared to the calculated emission strengths given in the CHIANTI atomic database. Normalizing the strongest line in each charge state to the CHIANTI predictions, we obtained the differences between the measured and predicted values for the relative strengths of the other lines of a given charge state. We find that a 3rd degree polynomial function provides a good fit to the data points. Our measurements show that the responsivity between about 120 and 300 Å varies by factor of ∼30.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DENSITY DETERMINATIONS OF THE CORONAE OF COOL STARS USING A NEWLY ASSIGNED PAIR OF Fe xiv LINES IN THE SPECTRA OF α CANIS MINOR, α CENTAURI, AND THE SUN

We have identified a previously unassigned pair of lines between 169 and 170 Å in the coronae of cool stars. We attribute these lines to Fe xiv and show that their intensity ratio is sensitive to the electron density. Using observations taken with the Low Energy Transmission Grating Spectrometer of the Chandra X-ray Observatory we infer a density of log(n{sub e}/cm{sup −3}) = 10.2 ± 0.7 and 10.3 ± 0.8 from the newly identified line pair in the coronae of Procyon and α Cen A, respectively.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic-Field Sensitive Line Ratios in EUV and Soft X-ray Spectra

We discovered a class of lines that are sensitive to the strength of the ambient magnetic field, and present a measurement of such a line in Ar IX near 49 A. Calculations show that the magnitude of field strengths that can be measured ranges from a few hundred gauss to several tens of kilogauss depending on the particular ion emitting the line.

Beiersdorfer, P.↗

Laboratory Measurements of the Line Emission from Mid-Z L-Shell Ions in the EUV

We are continuing EBIT measurements of line lists in the EUV region for use as astrophysical diagnostics and have recently measured the same transitions in much denser plasma of the NSTX tokamak. This allows us to calibrate density-sensitive line ratios at their upper limits. We compare our observations at low and high density with calculations from the Flexible Atomic Code.

Lepson, J. K.↗

Emission Line Spectra in the Soft X-ray Region 20 - 75 Angstroms

As part of a project to complete a comprehensive catalogue of astrophysically relevant emission lines in support of new-generation X-ray observatories using the Lawrence Livermore electron beam ion traps EBIT-I and EDIT-II, emission lines of argon and sulfur in the soft X-ray and extreme ultraviolet region were studied. Observations of Ar IX through Ar XVI and S VII through S XIV between 20 and 75 Angstrom are presented to illustrate our work.

Lepson, J. K.↗

Laboratory Data for X-Ray Astronomy

Laboratory facilities have made great strides in producing large sets of reliable data for X-ray astronomy, which include ionization and recombination cross sections needed for charge balance calculations as well as the atomic data needed for interpreting X-ray line formation. We discuss data from the new generation sources and pay special attention to the LLNL electron beam ion trap experiment, which is unique in its ability to provide direct laboratory access to spectral data under precisely controlled conditions that simulate those found in many astrophysical plasmas. Examples of spectral data obtained in the 1-160 A wavelength range are given illustrating the type of laboratory X-ray data produced in support of such missions as Chandra, X-Ray Multi-Mirror telescope (XMM), Advanced Satellite for Cosmology and Astrophysics (ASCA) and Extreme Ultraviolet Explorer Satellite (EUVE).

Beiersdorfer, P.↗

Emission Line Spectra from Low-Density Laboratory Plasmas

Using spectroscopic equipment optimized for laboratory astrophysics, we are performing systematic measurements of the line emission from astrophysically relevant ions in the wavelength band between 1 and 400 Angstroms important to X-ray missions such as Chandra, XMM, Astro-E, and EUVE. Obtained in a controlled laboratory setting at electron densities similar to those found in stellar coronae, the data are used to test spectral modeling codes for accuracy and completeness. Our effort includes the compilation of the iron L-shell emission lines from 6-18 Angstroms and the iron M-shell emission lines from 50-200 Angstroms. Many lines have been identified for the first time, and the fluxes from lines missing in the spectral modeling codes are assessed. Our measurements also assess the accuracy of line excitation calculations, including direct electron-impact excitation, dielectronic recombination, and resonance excitation. These measurements yield a calibration of specific diagnostic line ratios. Examples of our current measurements are given.

Beiersdorfer, P.↗