Search NASA⌕ Search

Engineering topics

Leventhal, M.

Publications and source records attributed to Leventhal, M..

27 records · Page 2

The Gamma-Ray Imaging Spectrometer (GRIS): A new balloon-borne experiment for gamma-ray line astronomy

High resolution gamma-ray spectroscopy is a relatively new field that holds great promise for further understanding of high energy astrophysical processes. When the high resolution gamma-ray spectrometer (GRSE) was removed from the GRO payload, a balloon program was initiated to permit continued development and improvement of instrumentation in this field, as well as continued scientific observations. The Gamma-Ray Imaging Spectrometer (GRIS) is one of the experiments selected as part of this program. The instrument contains a number of new and innovative features that are expected to produce a significant improvement in source location accuracy and sensitivity over previous balloon and satellite experiments.

Teegarden, B. J.↗

The development of a segmented N-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented. Previously announced in STAR as N84-13039

Gehrels, N.↗

High-velocity iron absorption lines in supernova remnant 1006

The very strong, broad absorption lines of a sdOB star continuum shown in the International Ultraviolet Explorer spectrum of the Schweizer-Middleditch star projected near the center of supernova remnant SNR 1006 are investigated. It is found that strong Fe(+) resonance absorption lines are present whose centers show zero radial velocity while their profiles are broadened by approximately 5000-6000 km/s. Also identified are redshifted Si(+), Si(2+), and Si(3+) lines at velocities of approximately 5000 km/s. Results show that the absorptions must occur in the ejecta of the supernova. The strength and symmetric width of the Fe(+) line indicates that the bulk of the ejecta is iron, in agreement with the current theory for the origin of Type I supernova. It is suggested that the previous failure to detect strong Fe emission lines in the X-ray spectra of this and other young Type I SNRs may be a result of the ejecta not having had time to interact significantly with the ambient medium. In addition, the presence of redshifted adsorption lines due to supernova ejecta in its spectrum shows that this star is located behind the SNR and is not physically associated with it.

Wu, C.-C.↗

Development of a segmented n-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented.

Gehrels, N.↗

Spectroscopy from 2 to 200 keV

The astrophysical processes responsible for line and continuum emission in the spectra range 2 keV to 200 keV are examined from the viewpoint of designing a spectrometer which would operate in this regime. Phenomena considered include fluorescent line radiation in X-ray binaries, magnetically shifted iron lines and cyclotron emission from neutron star surfaces, line emission from cosmically abundant elements in thermal plasmas, and nuclear deexcitation lines in fresh nucleosynthetically produced matter. An instrument consisting of a approximately 10 sq cm array of planar germanium detectors surrounded by a large sodium-iodide anticoincidence shield is described and projected background rates and sensitivities are considered. A sample observing program for a two-day shuttle-based mission is included as an example of the wide range of scientific questions which could be addressed by such an instrument.

Helfand, D. J.↗

Detection of 511 keV positron annihilation radiation from the galactic center direction

A balloon-borne gamma ray telescope with an approximately 130 cu cm high purity germanium detector was flown over Australia to detect sharp spectral features from the galactic center direction. A 511 keV positron annihilation line was observed at a flux level of (1.21 plus or minus 0.22) x (10/cu cm) photons/sec/sp cm. Suggestive evidence for the detection of the three-photon positronium continuum is presented. The possible origin of the positrons is discussed.

Leventhal, M.↗