Li, Ailin

Publications and source records attributed to Li, Ailin.

Mobility Selective Ion Soft-Landing and Characterization Enabled Using Structures for Lossless Ion Manipulation

In this study, while conventional ion-soft landing uses the mass-to-charge (m/z) ratio to achieve molecular selection for deposition, here we demonstrate the use of Structures for Lossless Ion Manipulation (SLIM) for mobility-based ion selection and deposition. The dynamic rerouting capabilities of SLIM were leveraged to enable the rerouting of a selected range of mobilities to a different SLIM path (rather than MS) that terminated at a deposition surface. A selected mobility range from a phosphazene ion mixture was rerouted and deposited with a current pulse (~150 pA) resembling its mobility peak. In addition, from a mixture of tetra-alkyl ammonium (TAA) ions containing chain lengths of C5–C8, selected chains (C6, C7) were collected on a surface, reconstituted into solution-phase, and subsequently analyzed with a SLIM-qToF to obtain an IMS/MS spectrum, confirming the identity of the selected species. Further, this method was used to characterize triply charged tungsten-polyoxometalate anions, PW 12 O 40 3– (WPOM). The arrival time distribution of the IMS/MS showed multiple peaks associated with the triply charged anion (PW 12 O 40 3– ), of which a selected ATD was deposited and imaged using TEM. Additionally, the identity of the deposited WPOM was ascertained using energy-dispersive (EDS) spectroscopy. Further, we present theory and computations that reveal ion landing energies, the ability to modulate the energies, and deposition spot sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Device and method to manipulate ions in multi-level system

An apparatus includes multiple levels of ion transport channels, with successive levels coupled by elevator channels. Efficient three dimensional packing provides long path lengths in practical volumes for ion mobility separation with high resolving power. Disclosed elevator configurations provide efficient routing of ion transport channels across levels with low ion loss, enabling ion mobility separation over 100 levels or more. Elevator configurations include (i) opposed traveling waves meeting at an elevator entrance, (ii) external elevator with a wrap-around electrode bank, (iii) external elevator with electrode banks on parallel extension plates, or (iv) elevator operating in surfing mode, in various combinations. Manufacture is aided by printed wiring boards, with interchangeable boards. Assembly with motherboard, spacer block(s), and alignment pins provides efficient distribution of electrode excitations and accurate reproducible positioning.

Ibrahim, Yehia M.↗

Device and method to manipulate ions in multi level system

An apparatus includes multiple levels of ion transport channels, with successive levels coupled by elevator channels. Efficient three dimensional packing provides long path lengths in practical volumes for ion mobility separation with high resolving power. Disclosed elevator configurations provide efficient routing of ion transport channels across levels with low ion loss, enabling ion mobility separation over 100 levels or more. Elevator configurations include (i) opposed traveling waves meeting at an elevator entrance, (ii) external elevator with a wrap-around electrode bank, (iii) external elevator with electrode banks on parallel extension plates, or (iv) elevator operating in surfing mode, in various combinations. Manufacture is aided by printed wiring boards, with interchangeable boards. Assembly with motherboard, spacer block(s), and alignment pins provides efficient distribution of electrode excitations and accurate reproducible positioning.

Ibrahim, Yehia M.↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Assessing Collision Cross Section Calibration Strategies for Traveling Wave-Based Ion Mobility Separations in Structures for Lossless Ion Manipulations

The collision cross section (CCS) is an important property that aids in the structural characterization of molecules. Here, we investigated the CCS calibration accuracy with traveling waves ion mobility spectrometry (TWIMS) separations in structures for lossless ion manipulations (SLIM) using three sets of calibrants. A series of singly negatively-charged phospholipids and bile acids were calibrated in nitrogen buffer gas using two different TW waveform profiles (square and sine) and amplitudes (20 V0-p, 25 V0-p, and 30 V 0-p ). The calibration errors for the three calibrant sets Agilent tuning mixture and polyalanine, and one assembled in-house showed negligible differences using a sine-shaped TW waveform. Furthermore, calibration errors were all within 1-2 % of the DTIMS measurements, with lower errors for sine waveforms, presumably due to the lower average and maximum fields experienced by ions. Finally, ultrahigh resolution multi-pass (long path length) SLIM TWIMS demonstrated improved CCS calibration for phospholipid and bile acid isomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion Mobility Spectrometry with High Ion Utilization Efficiency Using Traveling Wave-Based Structures for Lossless Ion Manipulations

Ion packets introduced from gates, ion funnel traps, and other conventional ion injection mechanisms produce ion pulse widths typically around a few microseconds or less for ion mobility spectrometry (IMS)-based separations on the order of 100 milliseconds. When such ion injection techniques are coupled with ultralong path length traveling wave (TW)-based IMS separations (i.e., on the order of seconds) using structures for lossless ion manipulations (SLIMs), typically very low ion utilization efficiency is achieved for continuous ion sources [e.g., electrospray ionization (ESI)]. Even with the ability to trap and accumulate much larger populations of ions than being conventionally feasible over longer time periods in SLIM devices, the subsequent long separations lead to overall low ion utilization. In this study, we report the use of a highly flexible SLIM arrangement, enabling concurrent ion accumulation and separation and achieving near-complete ion utilization with ESI. We characterize the ion accumulation process in SLIM, demonstrate >98% ion utilization, and show both increased signal intensities and measurement throughput. This approach is envisioned to have broad utility to applications, for example, involving the fast detection of trace chemical species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Improved Miniaturized Linear Ion Trap Mass Spectrometer Using Lithographically Patterned Plates and Tapered Ejection Slit

We present a new two-plate linear ion trap mass spectrometer that overcomes both performance-based and miniaturization-related issues with prior designs. Borosilicate glass substrates are patterned with aluminum electrodes on one side and wire-bonded to printed circuit boards. Ions are trapped in the space between two such plates. Tapered ejection slits in each glass plate eliminate issues with charge build-up within the ejection slit and with blocking of ions that are ejected at off-nominal angles. The tapered slit allows miniaturization of the trap features (electrode size, slit width) needed for further reduction of trap size while allowing the use of substrates that are still thick enough to provide ruggedness during handling, assembly, and in-field applications. Plate spacing was optimized during operation using a motorized translation stage. A scan rate of 2300 Th/s with a sample mixture of toluene and deuterated toluene (D8) and xylenes (a mixture of o-, m-, p-) showed narrowest peak widths of 0.33 Th (FWHM). .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anion-Functionalized Task-Specific Ionic Liquids: Molecular Origin of Change in Viscosity upon CO 2 Capture

The structure and dynamics of a task-specific ionic liquid (TSIL), trihexyl(tetradecyl)phosphonium imidazolate, before and after absorbing CO 2 were studied with a molecular dynamics (MD) simulation. This particular ionic liquid is one of several newly discovered azole-based TSILs for equimolar CO 2 capture. Unlike other TSILs whose viscosity increases drastically upon reaction with CO 2 , its viscosity decreases after CO 2 absorption. This unique behavior was confirmed in our MD simulation. In this study, we find that after CO 2 absorption the translational dynamics of the whole system is accelerated, accompanied by an accelerated rotational dynamics of the cations. Radial distribution function and spatial distribution function analyses show that the anions become asymmetric after reaction with CO 2 , and this causes the imbalance of the interaction between the positive and negative regions of the ions. The interaction between the phosphorus atom of the cation and oxygen atoms of the carboxyl group on the anion is enhanced, while that between the phosphorus atom and the naked nitrogen atom of the anion is weakened. The ion-pair correlation functions further support that the weakened interaction leads to faster dissociation of cation–anion pairs, thereby causing an accelerated dynamics. Hence, the asymmetry of anions influences the dynamics of the system and affects the viscosity. In conclusion, this insight may help design better TSILs with decreased viscosity for CO 2 capture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗