Search NASA⌕ Search

Engineering topics

Li, C. K. (ORCID:0000000269194881)

Publications and source records attributed to Li, C. K. (ORCID:0000000269194881).

A compact x-ray spectrometer for measurements of electron temperature distributions in inertial confinement fusion implosions at OMEGA

The Wedge Range Filter (WRF), commonly used for proton spectroscopy at the OMEGA Laser Facility and National Ignition Facility, is adapted to measure the x-ray continuum spectrum through transmission measurement using a continuous-gradient filter. Continuum x rays emitted from the hotspot of an implosion contain information about the plasma composition and electron temperature. The WRF data are leveraged to probe this distribution, specifically the electron temperature distribution. In this work, the data recorded with the WRF are forward modeled using a temperature distribution model folded with the WRF response function. An uncertainty analysis is conducted through a Bayesian regression algorithm using a Hamiltonian Monte Carlo sampler. This analysis enables the uncertainties in the instrument response to be folded into the uncertainty estimation of the electron temperature and absolute x-ray emission. Data analysis for a series of OMEGA implosions is presented and compared with radiation hydrodynamic simulations.

Lasers↗

Monte Carlo toolkit for designing and validating step-range-filter spectrometer designs

Here, we present a Monte Carlo toolkit for validating step range filter (SRF) spectrometer designs. Geant4 is used to transport charged particles through the SRF filters to generate synthetic SRF data that include realistic CR-39 effects. Synthetic SRF spectra generated by this method inherently account for instrument response and allow for the quantification of SRF performance before shots. The usefulness of this toolkit is demonstrated through its application to a number of problems. A new broadband SRF for the ∼10 MeV wide 3He3He proton spectrum is validated, and an analysis method for analyzing 3He3He-p SRF data that accounts for instrument response is put forth. In addition, an SRF design for the compact recoil-proton spectrometer (CRS) on the Z-machine is validated. Finally, a new calibration technique for the DD-p SRF is proposed and validated.

Johnson, T. M. (ORCID:0000000193032949)↗

Ultra-fast single-crystal CVD diamonds in the particle time-of-flight (PTOF) detector for low yield burn-history measurements on the NIF (invited)

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium–tritium (DT) fusion plasmas. PTOF-inferred DT burn width numbers compare well with widths inferred from the gamma reaction history diagnostic on mid-yield (1013–1015) shots, where both systems are capable of making this measurement. These new capabilities could be extended to 2.5 MeV deuterium–deuterium neutrons from D plasmas and to even lower yield by reducing the detector standoff distance to 10 cm; a design for this is also presented.

42 ENGINEERING↗

Diagnosing hot-spot symmetry in surrogate ignition experiments via secondary DT-neutron spectroscopy at the NIF

The directional energy spectrum of neutrons generated from the in-flight fusion reaction of 1-MeV tritons contains information about the hot-spot symmetry. The National Ignition Facility (NIF) fields Symmetry Capsule (Symcap) implosions, which have historically measured the symmetry of the radiation, drive by measuring the hot-spot shape via x-ray self-emission. Symcaps are used to tune the hot-spot symmetry for ignition experiments at the NIF. This work shows the relationship between directional secondary DT-n spectra and x-ray imaging data for a large database of Symcap implosions. A correlation is observed between the relative widths of the DT-n spectra measured with nTOFs and the shape measured with x-ray imaging. A Monte Carlo model, which computes the directional secondary DT-n spectrum, is used to interpret the results. A comparison of the x-ray and secondary DT-n data with the Monte Carlo model indicates that 56% of the variance between the two datasets is explained by a P2 asymmetry. More advanced simulations using HYDRA suggest that the unaccounted variance is due to P1 and P4 asymmetries present in the hot spot. The comparison of secondary DT-n data and x-ray imaging data to the modeling shows the DT-n data contain important information that supplements current P2 measurements and contain new information about the P1 asymmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a platform for experimental and computational studies of magnetic and radiative effects on astrophysically relevant jets at OMEGA

Accurate modeling of astrophysical jets is critical for understanding accretion systems and their impact on the interstellar medium. While astronomical observations can validate models, they have limitations. Controlled laboratory experiments offer a complementary approach for qualitative and quantitative demonstration. Laser experiments offer a complementary approach. This article introduces a new platform on the OMEGA laser facility for high-velocity (1500 kms−1), high-aspect-ratio (∼36) jet creation with strong cylindrical symmetry. This platform's capabilities bridge observational gaps, enabling controlled initial conditions and direct measurements of plasma characteristics, crucial for refining astrophysical jet dynamics and improving the models accuracy.

Rigon, G. (ORCID:0000000256664725)↗