Search NASA⌕ Search

Engineering topics

Li, D

Publications and source records attributed to Li, D.

At least 37 records · Page 2

Pressure-induced phase transitions in rubidium azide: Studied by in-situ x-ray diffraction

We present the in-situ X-ray diffraction studies of RbN{sub 3} up to 42.0 GPa at room temperature to supplement the high pressure exploration of alkali azides. Two pressure-induced phase transitions of α-RbN{sub 3} → γ-RbN{sub 3} → δ-RbN{sub 3} were revealed at 6.5 and 16.0 GPa, respectively. During the phase transition of α-RbN{sub 3} → γ-RbN{sub 3}, lattice symmetry decreases from a fourfold to a twofold axis accompanied by a rearrangement of azide anions. The γ-RbN{sub 3} was identified to be a monoclinic structure with C2/m space group. Upon further compression, an orthogonal arrangement of azide anions becomes energetically favorable for δ-RbN{sub 3}. The compressibility of α-RbN{sub 3} is anisotropic due to the orientation of azide anions. The bulk modulus of α-RbN{sub 3} is 18.4 GPa, quite close to those of KN{sub 3} and CsN{sub 3}. By comparing the phase transition pressures of alkali azides, their ionic character is found to play a key role in pressure-induced phase transitions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-F-17A-04: Respiratory Phase-Resolved 3D MRI with Isotropic High Spatial Resolution: Determination of the Average Breathing Motion Pattern for Abdominal Radiotherapy Planning

Purpose: To develop a retrospective 4D-MRI technique (respiratory phase-resolved 3D-MRI) for providing an accurate assessment of tumor motion secondary to respiration. Methods: A 3D projection reconstruction (PR) sequence with self-gating (SG) was developed for 4D-MRI on a 3.0T MRI scanner. The respiration-induced shift of the imaging target was recorded by SG signals acquired in the superior-inferior direction every 15 radial projections (i.e. temporal resolution 98 ms). A total of 73000 radial projections obtained in 8-min were retrospectively sorted into 10 time-domain evenly distributed respiratory phases based on the SG information. Ten 3D image sets were then reconstructed offline. The technique was validated on a motion phantom (gadolinium-doped water-filled box, frequency of 10 and 18 cycles/min) and humans (4 healthy and 2 patients with liver tumors). Imaging protocol included 8-min 4D-MRI followed by 1-min 2D-realtime (498 ms/frame) MRI as a reference. Results: The multiphase 3D image sets with isotropic high spatial resolution (1.56 mm) permits flexible image reformatting and visualization. No intra-phase motion-induced blurring was observed. Comparing to 2D-realtime, 4D-MRI yielded similar motion range (phantom: 10.46 vs. 11.27 mm; healthy subject: 25.20 vs. 17.9 mm; patient: 11.38 vs. 9.30 mm), reasonable displacement difference averaged over the 10 phases (0.74mm; 3.63mm; 1.65mm), and excellent cross-correlation (0.98; 0.96; 0.94) between the two displacement series. Conclusion: Our preliminary study has demonstrated that the 4D-MRI technique can provide high-quality respiratory phase-resolved 3D images that feature: a) isotropic high spatial resolution, b) a fixed scan time of 8 minutes, c) an accurate estimate of average motion pattern, and d) minimal intra-phase motion artifact. This approach has the potential to become a viable alternative solution to assess the impact of breathing on tumor motion and determine appropriate treatment margins. Comparison with 4D-CT in a clinical setting is warranted to assess the value of 4D-MRI in radiotherapy planning. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase-based target volume while avoiding typical motion artifacts found in 4D-CT, and is being further studied for use in GI targeting and motion management. This work supported in part by grant 1R03CA173273-01.

60 APPLIED LIFE SCIENCES↗

Improvement of near-infrared absorption linewidth in AlGaN/GaN superlattices by optimization of delta-doping location

We report a systematic study of the near-infrared intersubband absorption in AlGaN/GaN superlattices grown by plasma-assisted molecular-beam epitaxy as a function of Si-doping profile with and without {delta}-doping. The transition energies are in agreement with theoretical calculations including many-body effects. A dramatic reduction of the intersubband absorption linewidth is observed when the {delta}-doping is placed at the end of the quantum well. This reduction is attributed to the improvement of interface roughness. The linewidth dependence on interface roughness is well reproduced by a model that considers the distribution of well widths measured with transmission electron microscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Growth rate and start current in Smith-Purcell free-electron lasers

This letter reports a theory to calculate the growth rate and start current of a Smith-Purcell free-electron laser, which is a promising radiation source in the terahertz domain. A two-dimensional model was used to investigate the interaction between a sheet electron beam and the surface wave above a lamellar grating. After deriving the growth rate from the dispersion equation, the start current was carefully estimated by considering the power flow above the grating. The agreement between the predictions of our theory and the results from the particle-in-cell simulations is acceptable.

07 ISOTOPE AND RADIATION SOURCES↗

PXIE: Project X Injector Experiment

A multi-MW proton facility, Project X, has been proposed and is currently under development at Fermilab. We are planning a program of research and development aimed at integrated systems testing of critical components comprising the front end of the Project X. This program is being undertaken as a key component of the larger Project X R&D program. The successful completion of this program will validate the concept for the Project X front end, thereby minimizing a primary technical risk element within Project X. Integrated systems testing, known as the Project X Injector Experiment (PXIE), will be accomplished with a new test facility under construction at Fermilab and will be completed over the period FY12-16. PXIE will include an H{sup -} ion source, a CW 2.1-MeV RFQ and two superconductive RF (SRF) cryomodules providing up to 25 MeV energy gain at an average beam current of 1 mA (upgradable to 2 mA). Successful systems testing will also demonstrate the viability of novel front end technologies that are expected find applications beyond Project X.

43 PARTICLE ACCELERATORS↗