Engineering topics
Li, Gaojin
Publications and source records attributed to Li, Gaojin.
Electroconvection near an ion-selective surface with Butler–Volmer kinetics
We study the effects of interfacial kinetics on the electro-hydrodynamics of ion transport near an ion-selective surface using a combination of linear stability analysis and numerical simulation. The finite kinetics of the electrolyte–electrode interface affects the ion transfer and electroconvection in many ways. On a surface of fixed topography, such as a metal surface of slow and stable ion deposition or covered by a polymer membrane, the finite kinetics reduces the current in one-dimensional ion diffusion/migration, increases the critical voltage for the onset of the electroconvective instability, changes the dynamics of the electroconvection and the overlimiting current, and enhances the lateral ion diffusion within the interfacial layer. The first three effects are indirectly caused by the reaction kinetics and can be characterized by an effective voltage difference across the liquid electrolyte. In comparison, the last effect is controlled by a direct interplay between kinetics and nonlinear electroconvection. Scaling laws for ion transport and features of electroconvection are proposed. We also analyse the linear stability of a surface which evolves under ion deposition and find that the finite kinetics decreases the growth rate of both electroconvective and morphological instabilities and therefore modifies the wavenumber of the most unstable mode.
Suppression of electroconvective and morphological instabilities by an imposed cross flow of the electrolyte
Electroconvective (EC) instability and its influence on surface morphological perturbations (Morph) are important in many applications, including electrodialysis, batteries, and fuel cells. In this work, we study the effects of a two-dimensional channel flow on the EC and Morph instabilities using two approaches. In the bulk analysis, we derive the asymptotic solutions for small and large wave numbers by neglecting the space charge layer and imposing a second kind electroosmosis slip velocity boundary condition on the electroneutral bulk region. In the full analysis, the instability of the entire region of the liquid electrolyte is analyzed using the ultraspherical spectral method. Both studies show that the flow significantly affects the EC instability. The imposed flow distorts the concentration field, causing a sheltering effect which hinders the ion transport from low- to high-concentration regions, and therefore suppresses the EC instability below a certain wave number. In combination with the viscous stabilization of the high wave number modes by the space charge layer, a sufficiently strong imposed flow can fully suppress the EC instability. The increment in the critical voltage for the instability onset is roughly proportional to the square root of the product of imposed velocity and double layer thickness. The imposed flow has a smaller effect on the Morph instability, except that it may remove the morphological modes resulting from the EC instability and thereby change the wave number of the most unstable mode.
Suppression of dendrite growth by cross-flow in microfluidics
A cross-flow in microfluidics suppresses dendrite growth and electroconvection during electrodeposition.
Structure, Rheology, and Electrokinetics of Soft Colloidal Suspension Electrolytes
Abstract not provided
Spontaneous and field-induced crystallographic reorientation of metal electrodeposits at battery anodes
The propensity of metal anodes of contemporary interest (e.g., Li, Al, Na, and Zn) to form non-planar, dendritic morphologies during battery charging is a fundamental barrier to achievement of full reversibility. We experimentally investigate the origins of dendritic electrodeposition of Zn, Cu, and Li in a three-electrode electrochemical cell bounded at one end by a rotating disc electrode. We find that the classical picture of ion depletion–induced growth of dendrites is valid in dilute electrolytes but is essentially irrelevant in the concentrated (≥1 M) electrolytes typically used in rechargeable batteries. Using Zn as an example, we find that ion depletion at the mass transport limit may be overcome by spontaneous reorientation of Zn crystallites from orientations parallel to the electrode surface to dominantly homeotropic orientations, which appear to facilitate contact with cations outside the depletion layer. This chemotaxis-like process causes obvious texturing and increases the porosity of metal electrodeposits.
Electrodeposition of Zinc in Aqueous Electrolytes Containing High Molecular Weight Polymers
Strong polarization of the ion distribution in liquid electrolytes subjected to potential differences exceeding the thermal voltage, V T = kT/e, produces a hydrodynamic instability termed electroconvection at ion-selective interfaces. Electroconvection is desirable in some situations (e.g., electrodialysis) because it promotes mixing in a stagnant electrolyte layer, enhancing the ion flux at a fixed potential difference. It is undesirable in others (e.g., electrodeposition of metals) where early experiments show that convective fluid rolls associated with hydrodynamic instability in bounded electrolytes produce preferential metal deposition at localized regions on an electrode. Such localized deposition drives the family of morphological instabilities loosely termed dendritic electrodeposition. We experimentally investigate the effect of ultrahigh molecular weight polymer additives on the onset conditions and physical characteristics of both instabilities. Direct observations of electrodeposit morphology and tracer particle motions used in tandem with indirect electrokinetic measurements reveal that even at moderate concentrations, the polymer additives have a large beneficial effect in extending the range of electric potentials where stable electrodeposition is observed. Additionally, we report that at polymer concentrations above the entanglement threshold, high molecular weight polymers impart elasticity to liquid electrolytes which dampen electroconvective flow at a cation-selective interface but have at most a minimal effect on the bulk ionic conductivity of the liquid.