Search NASA⌕ Search

Engineering topics

Li, H

Publications and source records attributed to Li, H.

At least 19 records

A Global Methane Observation System to Reduce Uncertainty for Anthropogenic and Natural Sources and Sinks for Detecting and Attributing Climate Feedbacks

Atmospheric methane (CH4) concentrations are accelerating global warming as net emissions increase. Observing systems that quantify sources remain too sparse and fragmented to detect trends—especially in remote regions where climate‐driven natural emissions may be rising. We provide a framework for quantifying uncertainty reductions through the implementation of a global ecosystem‐methane observing system designed to: (i) substantially lower uncertainty in sectoral and regional emissions, (ii) separate co‐occurring anthropogenic and natural fluxes, and (iii) trend detection at regional scales to verify mitigation progress and provide early warning of natural feedbacks. Using bottom‐up inventories and process‐model ensembles for 2014–2023, we show that anthropogenic emissions remain uncertain by ∼32% globally, while natural sources—tropical and boreal‐arctic wetlands, fires, and inland waters—carry far larger uncertainties (+ 70%) and trend uncertainties reaching ∼200%. Additional observations must match spatial emission structure to increase observability of emissions: high‐resolution satellite constellations for point sources combined with expanded flux networks and wetland mapping for diffuse sources, and denser ground‐based atmospheric column measurements to restore observability in under‐sampled tropics and high latitudes. Notional analyses indicate that targeted additions of flux towers and ∼20 in situ atmospheric column concentration instruments per key tropical region could reduce continental‐scale uncertainties at modest cost. Conceptual illustration of a Global Ecosystem Methane Observing System (GEM‐OS) integrating satellites, aircraft, atmospheric networks, and ecosystem measurements to quantify methane emissions from anthropogenic and natural sources. The multi‐scale observing framework improves source attribution, reduces uncertainty in regional methane budgets, and enables early detection of climate‐driven feedbacks from wetlands, fires, permafrost, agriculture, and fossil‐fuel emissions.

Ciais, P↗

Optimize heat prosumers' economic performance under current heating price models by using water tank thermal energy storage

Due to heat prosumers' dual roles of heat producer and heat consumer, the future district heating (DH) systems will become more flexible and competitive. However, the current heating price models have not yet supported the reverse heat supply from prosumers to the central DH system, which means the prosumers would gain no economic benefit from supplying heat to the central DH system. These unidirectional heating price models will reduce interest in prosumers, and thus hinder the promotion of prosumers in DH systems. This study aimed to optimize prosumers' economic performance under the current heating price models by introducing water tank thermal energy storage (WTTES). A dynamic optimization problem was formulated to explore prosumers' economic potentials. The size parameter of WTTESs was swept in prosumers to obtain the optimal storage size considering the trade-off between the payback period and the heating cost saving. The proposed method was tested on a campus DH system in Norway. The results showed that the prosumer's annual heating cost was saved up to 9%, and the investment of WTTES could be recovered in less than ten years. This study could provide guidelines on improving prosumers' economic performance and promote the development of prosumers during the transformation period of DH systems.

Li, H↗

AlphaBuilding ResCommunity: A multi-agent virtual testbed for community-level load coordination

Training and validating algorithms in a simulation testbed can accelerate research and applications of optimal control of residential loads to improve energy flexibility and grid resilience. We developed an open-source simulation environment, AlphaBuilding ResCommunity, that can be used to train and validate algorithms to control a single thermostatically controlled load (TCL) or coordinate a group of TCLs. We used reduced-order models to simulate the thermodynamics of TCLs, and the parameter values were determined from the connected smart thermostat data of real households. The environment was built upon the standardized OpenAI Gym interface. Ancillary functions, such as retrieving the parameters and weather forecasts, are provided to facilitate control strategies that require predictive information. Compared with existing efforts, AlphaBuilding ResCommunity has three advantages: (1) more realistic model settings because the parameter values are identified from actual household operating data, and modelling and measurement uncertainty are considered; (2) passive thermal storage control; and (3) ease of use due to a simple software dependency and standardized interface. We demonstrated the applications of the environment by implementing a Kalman Filter and Model Predictive Control on a single TCL and a Priority-Stack-Based Control and Alternating Direction Method of Multipliers to coordinate multiple TCLs for load tracking.

Wang, Z↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

SU-D-204-07: Retrospective Correlation of Dose Accuracy with Regions of Local Failure for Early Stage Lung Cancer Patients Treated with Stereotactic Body Radiotherapy

Purpose: To correlate dose distributions computed using six algorithms for recurrent early stage non-small cell lung cancer (NSCLC) patients treated with stereotactic body radiotherapy (SBRT), with outcome (local failure). Methods: Of 270 NSCLC patients treated with 12Gyx4, 20 were found to have local recurrence prior to the 2-year time point. These patients were originally planned with 1-D pencil beam (1-D PB) algorithm. 4D imaging was performed to manage tumor motion. Regions of local failures were determined from follow-up PET-CT scans. Follow-up CT images were rigidly fused to the planning CT (pCT), and recurrent tumor volumes (Vrecur) were mapped to the pCT. Dose was recomputed, retrospectively, using five algorithms: 3-D PB, collapsed cone convolution (CCC), anisotropic analytical algorithm (AAA), AcurosXB, and Monte Carlo (MC). Tumor control probability (TCP) was computed using the Marsden model (1,2). Patterns of failure were classified as central, in-field, marginal, and distant for Vrecur ≥95% of prescribed dose, 95–80%, 80–20%, and ≤20%, respectively (3). Results: Average PTV D95 (dose covering 95% of the PTV) for 3-D PB, CCC, AAA, AcurosXB, and MC relative to 1-D PB were 95.3±2.1%, 84.1±7.5%, 84.9±5.7%, 86.3±6.0%, and 85.1±7.0%, respectively. TCP values for 1-D PB, 3-D PB, CCC, AAA, AcurosXB, and MC were 98.5±1.2%, 95.7±3.0, 79.6±16.1%, 79.7±16.5%, 81.1±17.5%, and 78.1±20%, respectively. Patterns of local failures were similar for 1-D and 3D PB plans, which predicted that the majority of failures occur in centraldistal regions, with only ∼15% occurring distantly. However, with convolution/superposition and MC type algorithms, the majority of failures (65%) were predicted to be distant, consistent with the literature. Conclusion: Based on MC and convolution/superposition type algorithms, average PTV D95 and TCP were ∼15% lower than the planned 1-D PB dose calculation. Patterns of failure results suggest that MC and convolution/superposition type algorithms predict different outcomes for patterns of failure relative to PB algorithms. Work supported in part by Varian Medical Systems, Palo Alto, CA.

60 APPLIED LIFE SCIENCES↗

SU-F-P-21: Study of Dosimetry Accuracy of Small Passively Scattered Proton Beam Fields

Purpose: To study the accuracy of the dose distribution of very small irregular fields of passively scattered proton beams calculated by the analytical pencil beam model of the Eclipse treatment planning system (TPS). Methods: An irregular field with a narrow region (width < 1 cm) that was used for the treatment of a small volume adjacent to a previously treated area were chosen for this investigation. Point doses at different locations inside the field were measured with a small volume ion chamber (A26, Standard Imaging). 2-D dose distributions were measured using a 2-D ion chamber array (MatriXX, IBA). All the measurements were done in plastic water phantom. The measured dose distributions were compared with the verification plan dose calculated in a water like phantom for the patient treatment field without the use of the compensator. Results: Point doses measured with the ion chamber in the narrowest section of the field were found to differ as much as 10% from the Eclipse calculated dose at some of the points. The 2-D dose distribution measured with the MatriXX which was validated by comparison with limited film measurement, at the proximal 95%, center of the spread out Bragg Peak and distal 90% depths agreed reasonably well with the TPS calculated dose distribution with more than 92% of the pixels passing the 2% / 2 mm dose distance agreement. Conclusion: The dose calculated by the pencil beam model of the Eclipse TPS for narrow irregular fields may not be accurate within 5% at some locations of the field, especially at the points close to the field edge due to the limitation of the dose calculation model. Overall accuracy of the calculated 2-D dose distribution was found to be acceptable for the 2%/2 mm dose/distance agreement with the measurement.

60 APPLIED LIFE SCIENCES↗

SU-F-J-72: A Clinical Usable Integrated Contouring Quality Evaluation Software for Radiotherapy

Purpose: To introduce the Auto Contour Evaluation (ACE) software, which is the clinical usable, user friendly, efficient and all-in-one toolbox for automatically identify common contouring errors in radiotherapy treatment planning using supervised machine learning techniques. Methods: ACE is developed with C# using Microsoft .Net framework and Windows Presentation Foundation (WPF) for elegant GUI design and smooth GUI transition animations through the integration of graphics engines and high dots per inch (DPI) settings on modern high resolution monitors. The industrial standard software design pattern, Model-View-ViewModel (MVVM) pattern, is chosen to be the major architecture of ACE for neat coding structure, deep modularization, easy maintainability and seamless communication with other clinical software. ACE consists of 1) a patient data importing module integrated with clinical patient database server, 2) a 2D DICOM image and RT structure simultaneously displaying module, 3) a 3D RT structure visualization module using Visualization Toolkit or VTK library and 4) a contour evaluation module using supervised pattern recognition algorithms to detect contouring errors and display detection results. ACE relies on supervised learning algorithms to handle all image processing and data processing jobs. Implementations of related algorithms are powered by Accord.Net scientific computing library for better efficiency and effectiveness. Results: ACE can take patient’s CT images and RT structures from commercial treatment planning software via direct user input or from patients’ database. All functionalities including 2D and 3D image visualization and RT contours error detection have been demonstrated with real clinical patient cases. Conclusion: ACE implements supervised learning algorithms and combines image processing and graphical visualization modules for RT contours verification. ACE has great potential for automated radiotherapy contouring quality verification. Structured with MVVM pattern, it is highly maintainable and extensible, and support smooth connections with other clinical software tools.

60 APPLIED LIFE SCIENCES↗

SU-F-J-102: Lower Esophagus Margin Implications Based On Rapid Computational Algorithm for SBRT

Purpose: To quantify inter-fraction esophagus-variation. Methods: Computed tomography and daily on-treatment 0.3-T MRI data sets for 7 patients were analyzed using a novel Matlab-based (Mathworks, Natick, MA) rapid computational method. Rigid registration was performed from the cricoid to the gastro-esophageal junction. CT and MR-based contours were compared at slice intervals of 3mm. Variation was quantified by “expansion,” defined as additional length in any radial direction from CT contour to MR contour. Expansion computations were performed with 360° of freedom in each axial slice. We partitioned expansions into left anterior, right anterior, right posterior, and left posterior quadrants (LA, RA, RP, and LP, respectively). Sample means were compared by analysis of variance (ANOVA) and Fisher’s Protected Least Significant Difference test. Results: Fifteen fractions and 1121 axial slices from 7 patients undergoing SBRT for primary lung cancer (3) and metastatic lung disease (4) were analyzed, generating 41,970 measurements. Mean LA, RA, RP, and LP expansions were 4.30±0.05 mm, 3.71±0.05mm, 3.17±0.07, and 3.98±0.06mm, respectively. 50.13% of all axial slices showed variation > 5 mm in one or more directions. Variation was greatest in lower esophagus with mean LA, RA, RP, and LP expansion (5.98±0.09 mm, 4.59±0.09 mm, 4.04±0.16 mm, and 5.41±0.16 mm, respectively). The difference was significant compared to mid and upper esophagus (p<.0001). The 95th percentiles of expansion for LA, RA, RP, LP were 13.36 mm, 9.97 mm, 11.29 mm, and 12.19 mm, respectively. Conclusion: Analysis of on-treatment MR imaging of the lower esophagus during thoracic SBRT suggests margin expansions of 13.36 mm LA, 9.97 mm RA, 11.29 mm RP, 12.19 mm LP would account for 95% of measurements. Our novel algorithm for rapid assessment of margin expansion for critical structures with 360° of freedom in each axial slice enables continuously adaptive patient-specific margins which may reduce overlap with high-dose regions.

60 APPLIED LIFE SCIENCES↗

SU-F-J-177: A Novel Image Analysis Technique (center Pixel Method) to Quantify End-To-End Tests

Purpose: To implement a novel image analysis technique, “center pixel method”, to quantify end-to-end tests accuracy of a frameless, image guided stereotactic radiosurgery system. Methods: The localization accuracy was determined by delivering radiation to an end-to-end prototype phantom. The phantom was scanned with 0.8 mm slice thickness. The treatment isocenter was placed at the center of the phantom. In the treatment room, CBCT images of the phantom (kVp=77, mAs=1022, slice thickness 1 mm) were acquired to register to the reference CT images. 6D couch correction were applied based on the registration results. Electronic Portal Imaging Device (EPID)-based Winston Lutz (WL) tests were performed to quantify the errors of the targeting accuracy of the system at 15 combinations of gantry, collimator and couch positions. The images were analyzed using two different methods. a) The classic method. The deviation was calculated by measuring the radial distance between the center of the central BB and the full width at half maximum of the radiation field. b) The center pixel method. Since the imager projection offset from the treatment isocenter was known from the IsoCal calibration, the deviation was determined between the center of the BB and the central pixel of the imager panel. Results: Using the automatic registration method to localize the phantom and the classic method of measuring the deviation of the BB center, the mean and standard deviation of the radial distance was 0.44 ± 0.25, 0.47 ± 0.26, and 0.43 ± 0.13 mm for the jaw, MLC and cone defined field sizes respectively. When the center pixel method was used, the mean and standard deviation was 0.32 ± 0.18, 0.32 ± 0.17, and 0.32 ± 0.19 mm respectively. Conclusion: Our results demonstrated that the center pixel method accurately analyzes the WL images to evaluate the targeting accuracy of the radiosurgery system. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

60 APPLIED LIFE SCIENCES↗

SU-F-J-178: A Computer Simulation Model Observer for Task-Based Image Quality Assessment in Radiation Therapy

Purpose: Traditionally, image quality in radiation therapy is assessed subjectively or by utilizing physically-based metrics. Some model observers exist for task-based medical image quality assessment, but almost exclusively for diagnostic imaging tasks. As opposed to disease diagnosis, the task for image observers in radiation therapy is to utilize the available images to design and deliver a radiation dose which maximizes patient disease control while minimizing normal tissue damage. The purpose of this study was to design and implement a new computer simulation model observer to enable task-based image quality assessment in radiation therapy. Methods: A modular computer simulation framework was developed to resemble the radiotherapy observer by simulating an end-to-end radiation therapy treatment. Given images and the ground-truth organ boundaries from a numerical phantom as inputs, the framework simulates an external beam radiation therapy treatment and quantifies patient treatment outcomes using the previously defined therapeutic operating characteristic (TOC) curve. As a preliminary demonstration, TOC curves were calculated for various CT acquisition and reconstruction parameters, with the goal of assessing and optimizing simulation CT image quality for radiation therapy. Sources of randomness and bias within the system were analyzed. Results: The relationship between CT imaging dose and patient treatment outcome was objectively quantified in terms of a singular value, the area under the TOC (AUTOC) curve. The AUTOC decreases more rapidly for low-dose imaging protocols. AUTOC variation introduced by the dose optimization algorithm was approximately 0.02%, at the 95% confidence interval. Conclusion: A model observer has been developed and implemented to assess image quality based on radiation therapy treatment efficacy. It enables objective determination of appropriate imaging parameter values (e.g. imaging dose). Framework flexibility allows for incorporation of additional modules to include any aspect of the treatment process, and therefore has great potential for both assessment and optimization within radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-188: Clinical Implementation of in Room Mobile CT for Image Guided Proton Therapy

Purpose: To implement soft-tissue image-guided proton therapy using inroom mobile CT. Methods: Anthropomorphic phantom was first used to determine the setup accuracy using in- room mobile CT. Laser and bbs were used for the initial setup (marked isocenter). CT data was then acquired with in-room mobile CT (daily CT). The shift between the marked isocenter and the planned isocenter (final isocenter) was determined from the daily CT using in-house Computer Assisted Targeting (CAT) software. Orthogonal DRRs of the day was also generated from the daily CT. The phantom was then transferred on the treatment couch top to the treatment machine using a transportation system, and again aligned to the marked isocenter. Couch shifts were made to align the phantom to the final isocenter using the shifts as determined using the CAT software, and verified using orthogonal X-ray images with the daily DRRs. Results: Phantom data suggests that following the setup procedure as described above, targeting accuracy could be within 1 mm. Patient data are being acquired and analyzed. Conclusion: In-room mobile CT is capable of providing soft-tissue image-guided proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-194: Development of Dose-Based Image Guided Proton Therapy Workflow

Purpose: To implement image-guided proton therapy (IGPT) based on daily proton dose distribution. Methods: Unlike x-ray therapy, simple alignment based on anatomy cannot ensure proper dose coverage in proton therapy. Anatomy changes along the beam path may lead to underdosing the target, or overdosing the organ-at-risk (OAR). With an in-room mobile computed tomography (CT) system, we are developing a dose-based IGPT software tool that allows patient positioning and treatment adaption based on daily dose distributions. During an IGPT treatment, daily CT images are acquired in treatment position. After initial positioning based on rigid image registration, proton dose distribution is calculated on daily CT images. The target and OARs are automatically delineated via deformable image registration. Dose distributions are evaluated to decide if repositioning or plan adaptation is necessary in order to achieve proper coverage of the target and sparing of OARs. Besides online dose-based image guidance, the software tool can also map daily treatment doses to the treatment planning CT images for offline adaptive treatment. Results: An in-room helical CT system is commissioned for IGPT purposes. It produces accurate CT numbers that allow proton dose calculation. GPU-based deformable image registration algorithms are developed and evaluated for automatic ROI-delineation and dose mapping. The online and offline IGPT functionalities are evaluated with daily CT images of the proton patients. Conclusion: The online and offline IGPT software tool may improve the safety and quality of proton treatment by allowing dose-based IGPT and adaptive proton treatments. Research is partially supported by Mevion Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-J-221: Adjusted Dose and Its Relation to Radiation Induced Liver Disease During Hepatocellular Carcinoma Radiotherapy

Purpose: Many patients with hepatocellular carcinoma (HCC) had hepatic anatomy variations as a result of inter-fraction deformation during fractionated radiotherapy, which may result in difference from the planned dose. This study aimed to investigate the relationship between adjusted dose and radiation induced liver disease (RILD) in HCC patients receiving three dimensional conformal radiotherapy (3DCRT). Methods: Twenty-three HCC patients received conventional fractionated 3DCRT were enrolled in this retrospective investigation. Among them, seven patients had been diagnosed of RILD post-radiotherapy, including 4 cases of grade 2, 3 cases of grade 3 according to the CTCAE Version 3.0. Daily cone-beam CT (CBCT) scans were acquired throughout the whole treatment course for each patient. To reconstruct the daily dose to a patient considering the interfraction anatomy variations, the planned beams from each patient’s treatment plan were firstly applied to each daily modified CBCT (mCBCT). The daily doses were then summed together with the help of deformable image registration (DIR) to obtain the adjusted dose (Dadjusted) of the patient. Finally, the dose changes in normal liver between planned dose (Dplan) and Dadjusted were evaluated by V20, V30, V40 and the mean dose to normal liver (MDTNL). Univariate analysis was performed to identify the significant dose changes. Results: Among the twenty-three patients, the adjusted liver V20, V30, V40 and MDTNL showed significant changes from the planned ones (p<0.05) and averagely increased by 4.1%, 4.7%, 4.5% and 3.9Gy, respectively. And the adjusted liver dose in twenty-one patients (91%) were higher than planned value, the adjusted dose of patients with RILD (6/7) exceeds to the hepatic radiation tolerance. Conclusion: The adjusted dose of all the studied patients significantly differs from planned dose, and mCBCT-based dose reconstruction can aid in evaluating the robustness of the planning solutions, and adjusted dose has the potential to reduce the risk of RILD. The author would like to express great thanks to Lei Xing, Daniel S Kapp and Yong Yang in the Stanford University School of Medicine for their valuable suggestions to this work.This work is supported by NSFC(61471226),China Postdoctoral Science Foundation (2015T80739, 2014M551949) and research funding from Shandong Province(JQ201516).

60 APPLIED LIFE SCIENCES↗

SU-F-T-103: Analysis of Hepatitis B Virus Reactivation After Conformal Radiotherapy in Patients with Hepatocellular Carcinoma Using the Lyman NTCP Model

Purpose: The aim of this research was to investigate the feasibility of Lyman-Kutcher-Burman (LKB) normal tissue complication probability (NTCP) model in analyzing hepatitis B virus (HBV) reactivation in patients receiving conformal radiotherapy for patients with hepatocellular carcinoma (HCC). Methods: Between June 2009 and June 2012, 108 HBV-related HCC patients (90 were specifically selected and 18 patients were excluded) treated with conformal RT at three centers were enrolled in this retrospective study. They were all diagnosed as HCC by pathology or cytology. All 90 patients were followed up to September 2013 with a median follow-up time of 25.2 months. The parameters (TD50 (1), n, and m) of the modified LKB NTCP model were derived using maximum likelihood estimation. Bootstrap and leave-one-out were employed to test the generalizability of the results for use in a general population. Results: The incidences of complications in the study population were as follows: radiation-induced liver diseases (RILD) were 17.6%, HBV reactivation was 24.8%, and HBV reactivation-induced hepatitis was 22.7%, respectively. In multivariate analysis, the NTCP (p<0.001), and V20 were associated with HBV reactivation. TD50 (1), m and n were 42.9Gy (95% CI) (38.2–46.8), 0.14 (0.12–0.15) and 0.30 (0.2–0.33), respectively, for HBV reactivation. Bootstrap and leave-one-out results showed that the HBV parameter fits were extremely robust. Conclusion: A modified LKB NTCP model has been established to predict HBV reactivation for patients with HCC receiving conformal RT. The finding derives parameters set to predict potential endpoints of HBV reactivation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-168: Development and Implementation of An Anthropomorphic Head & Neck Phantom for the Assessment of Proton Therapy Treatment Procedures

Purpose: To design a Head and Neck (H&N) anthropomorphic QA phantom that the Imaging and Radiation Oncology Core Houston (IROC-H) can use to verify the quality of intensity modulated proton therapy (IMPT) H&N treatments for institutions participating in NCI clinical trials. Methods: The phantom was created to serve as a remote auditing tool for IROC-H to evaluate an institution’s IMPT planning and delivery abilities. The design was based on the composition, size, and geometry of a generalized oropharyngeal tumor and contains critical structures (parotids and spinal cord). Radiochromic film in the axial and sagittal planes and thermoluminescent dosimeters (TLD)-100 capsules were embedded in the phantom and used to perform the dose delivery evaluation. A CT simulation was used to create a passive scatter and a spot scanning treatment plan with typical clinical constraints for H&N cancer. The IMPT plan was approved by a radiation oncologist and the phantom was irradiated multiple times. The measured dose distribution using a 7%/4mm gamma analysis (85% of pixels passing) and point doses were compared with the treatment planning system calculations. Results: The designed phantom could not achieve the target dose prescription and organ at risk dose constraints with the passive scatter treatment plan. The target prescription dose could be met but not the parotid dose constraint. The average TLD point dose ratio in the target was 0.975, well within the 5% acceptance criterion. The dose distribution analysis using various acceptance criteria, 5%/4mm, 5%/3mm, 7%/4mm and 7%/5mm, had average pixel passing rates of 85.9%, 81.8%, 89.6% and 91.6%, and respectively. Conclusion: An anthropomorphic IMPT H&N phantom was designed that can assess the dose delivery of proton sites wishing to participate in clinical trials using a 5% TLD dose and 7%/4mm gamma analysis acceptance criteria.

60 APPLIED LIFE SCIENCES↗

SU-F-T-192: Study of Robustness Analysis Method of Multiple Field Optimized IMPT Plans for Head & Neck Patients

Purpose: Proton therapy is more sensitive to uncertainties than photon treatments due to protons’ finite range depending on the tissue density. Worst case scenario (WCS) method originally proposed by Lomax has been adopted in our institute for robustness analysis of IMPT plans. This work demonstrates that WCS method is sufficient enough to take into account of the uncertainties which could be encountered during daily clinical treatment. Methods: A fast and approximate dose calculation method is developed to calculate the dose for the IMPT plan under different setup and range uncertainties. Effects of two factors, inversed square factor and range uncertainty, are explored. WCS robustness analysis method was evaluated using this fast dose calculation method. The worst-case dose distribution was generated by shifting isocenter by 3 mm along x,y and z directions and modifying stopping power ratios by ±3.5%. 1000 randomly perturbed cases in proton range and x, yz directions were created and the corresponding dose distributions were calculated using this approximated method. DVH and dosimetric indexes of all 1000 perturbed cases were calculated and compared with the result using worst case scenario method. Results: The distributions of dosimetric indexes of 1000 perturbed cases were generated and compared with the results using worst case scenario. For D95 of CTVs, at least 97% of 1000 perturbed cases show higher values than the one of worst case scenario. For D5 of CTVs, at least 98% of perturbed cases have lower values than worst case scenario. Conclusion: By extensively calculating the dose distributions under random uncertainties, WCS method was verified to be reliable in evaluating the robustness level of MFO IMPT plans of H&N patients. The extensively sampling approach using fast approximated method could be used in evaluating the effects of different factors on the robustness level of IMPT plans in the future.

60 APPLIED LIFE SCIENCES↗

SU-F-T-275: A Correlation Study On 3D Fluence-Based QA and 2D Dose Measurement-Based QA

Purpose: The aim of this paper was to demonstrate the feasibility and creditability of computing and verifying 3D fluencies to assure IMRT and VMAT treatment deliveries, by correlating the passing rates of the 3D fluence-based QA (P(ά)) to the passing rates of 2D dose measurementbased QA (P(Dm)). Methods: 3D volumetric primary fluencies are calculated by forward-projecting the beam apertures and modulated by beam MU values at all gantry angles. We first introduce simulated machine parameter errors (MU, MLC positions, jaw, gantry and collimator) to the plan. Using passing rates of voxel intensity differences (P(Ir)) and 3D gamma analysis (P(γ)), calculated 3D fluencies, calculated 3D delivered dose, and measured 2D planar dose in phantom from the original plan are then compared with those from corresponding plans with errors, respectively. The correlations of these three groups of resultant passing rates, i.e. 3D fluence-based QA (P(ά,Ir) and P(ά,γ)), calculated 3D dose (P(Dc,Ir) and P(Dc,γ)), and 2D dose measurement-based QA (P(Dm,Ir) and P(Dm,γ)), will be investigated. Results: 20 treatment plans with 5 different types of errors were tested. Spearman’s correlations were found between P(ά,Ir) and P(Dc,Ir), and also between P(ά,γ) and P(Dc,γ), with averaged p-value 0.037, 0.065, and averaged correlation coefficient ρ-value 0.942, 0.871 respectively. Using Matrixx QA for IMRT plans, Spearman’s correlations were also obtained between P(ά,Ir) and P(Dm,Ir) and also between P(ά,γ) and P(Dm,γ), with p-value being 0.048, 0.071 and ρ-value being 0.897, 0.779 respectively. Conclusion: The demonstrated correlations improve the creditability of using 3D fluence-based QA for assuring treatment deliveries for IMRT/VMAT plans. Together with advantages of high detection sensitivity and better visualization of machine parameter errors, this study further demonstrates the accuracy and feasibility of 3D fluence based-QA in pre-treatment QA and daily QA. Research reported in this study is supported by the Agency for Healthcare Research and Quality (AHRQ) under award 1R01HS0222888. The senior author received research grants from ViewRay Inc. and Varian Medical System.

60 APPLIED LIFE SCIENCES↗

SU-F-T-472: Validation of Absolute Dose Measurements for MR-IGRT With and Without Magnetic Field

Purpose: To validate absolute dose measurements for a MR-IGRT system without presence of the magnetic field. Methods: The standard method (AAPM’s TG-51) of absolute dose measurement with ionization chambers was tested with and without the presence of the magnetic field for a clinical 0.32-T Co-60 MR-IGRT system. Two ionization chambers were used - the Standard Imaging (Madison, WI) A18 (0.123 cc) and the PTW (Freiburg, Germany). A previously reported Monte Carlo simulation suggested a difference on the order of 0.5% for dose measured with and without the presence of the magnetic field, but testing this was not possible until an engineering solution to allow the radiation system to be used without the nominal magnetic field was found. A previously identified effect of orientation in the magnetic field was also tested by placing the chamber either parallel or perpendicular to the field and irradiating from two opposing angles (90 and 270). Finally, the Imaging and Radiation Oncology Core provided OSLD detectors for five irradiations each with and without the field - with two heads at both 0 and 90 degrees, and one head at 90 degrees only as it doesn’t reach 0 (IEC convention). Results: For the TG-51 comparison, expected dose was obtained by decaying values measured at the time of source installation. The average measured difference was 0.4%±0.12% for A18 and 0.06%±0.15% for Farmer chamber. There was minimal (0.3%) orientation dependence without the magnetic field for the A18 chamber, while previous measurements with the magnetic field had a deviation of 3.2% with chamber perpendicular to magnetic field. Results reported by IROC for the OSLDs with and without the field had a maximum difference of 2%. Conclusion: Accurate absolute dosimetry was verified by measurement under the same conditions with and without the magnetic field for both ionization chambers and independently-verifiable OSLDs.

60 APPLIED LIFE SCIENCES↗