Search NASA⌕ Search

Engineering topics

Li, M.

Publications and source records attributed to Li, M..

At least 19 records

In-situ kinetic study of irradiation induced crystallization in amorphous Al 2 O 3

In the last ten years amorphous alumina coatings, deposited by Pulsed Laser Deposition, emerged as potential key enabling technology in the fields of heavy liquid metal fast reactors (lead and lead-bismuth) and fusion. In the former, as coating of the steel fuel cladding and in the latter as multifunctional coating providing a barrier against tritium permeation, steel corrosion and electrical insulation. Nevertheless, a detailed knowledge of the behavior of this thermodynamically metastable material at high temperatures and under neutron irradiation is still unknown. A knowledge gap that is mandatory to fill up for the deployment of this barrier technology. In the present work, we present a first step towards this goal, by the in-situ dynamic observation of the radiation induced crystallization processes of thin films of amorphous Al 2 O 3 , induced by ion-irradiation over an extensive range of temperatures (400-800 °C). The study was performed at the Intermediate Voltage Electron Microscope (IVEM)-Tandem Facility at Argonne National Laboratory. The experimental findings allow to elucidate the dependence of the grain growth on ion dose and temperature. A kinetic approach has been used to derive the process activation energies and other important parameters.

36 MATERIALS SCIENCE↗

Investigating the effects of precise mass measurements of Ru and Pd isotopes on machine learning mass modeling

Atomic masses are a foundational quantity in our understanding of nuclear structure, astrophysics, and fundamental symmetries. The longstanding goal of creating a predictive global model for the binding energy of a nucleus remains a significant challenge, however, and prompts the need for precise measurements of atomic masses to serve as anchor points for model developments. We present precise mass measurements of neutron-rich Ru and Pd isotopes performed at the Californium Rare Isotope Breeder Upgrade facility at Argonne National Laboratory using the Canadian Penning Trap mass spectrometer. The masses of 108 Ru, 110 Ru, and 116 Pd were measured to a relative mass precision $\delta$⁢$m/m$ ≈ 10 -8 via the phase-imaging ion-cyclotron-resonance technique, and represent an improvement of approximately an order of magnitude over previous measurements. Further, these mass data were used in conjunction with the physically interpretable machine learning (PIML) model, which uses a mixture density neural network to model mass excesses via a mixture of Gaussian distributions. The effects of our new mass data on a Bayesian-updating of a PIML model are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Influence of excess silicon on polytype selection during metal-mediated epitaxy of GaN nanowires

For this work, we have examined the origins of polytype selection during metal-mediated molecular-beam epitaxy of GaN nanowires (NWs). High-angle annular dark-field scanning transmission electron microscopy reveals [111]-oriented zinc blende (ZB) NWs and [0001]-oriented wurtzite (WZ) NWs, with SixNy at the interface between individual NWs and the Si (001) substrate. Quantitative energy dispersive x-ray spectroscopy reveals a notably higher Si concentration of 7.0% ± 2.3% in zinc blende (ZB) NWs than 2.3% ± 1.2% in wurtzite (WZ) NWs. Meanwhile, density functional theory calculations show that incorporation of 8 at. % Si on the Ga sublattice inverts the difference in formation energies between WZ and ZB GaN, such that the ZB polytype of GaN is stabilized. This identification of Si and other ZB polytype stabilizers will enable the development of polytype heterostructures in a wide variety of WZ-preferring compounds.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Deep learning based event reconstruction for cyclotron radiation emission spectroscopy

The objective of the cyclotron radiation emission spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time–frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization—may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment—a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium β - -decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Characterization of TES-Based Detectors for the Ricochet Experiment

Coherent elastic neutrino-nucleus scattering (CE nu NS) offers a valuable approach in searching for physics beyond the standard model. The Ricochet experiment aims to perform a precision measurement of the CE nu NS spectrum at the Institut Laue-Langevin nuclear reactor with cryogenic solid-state detectors. The experiment plans to employ an array of cryogenic thermal detectors, each with a mass of around 30 g and an energy threshold of below 100 eV. The array includes nine detectors read out by transition-edge sensors (TES). These TES-based detectors will also serve as demonstrators for future neutrino experiments with thousands of detectors. In this article, we present an update on the characterization and modeling of a prototype TES detector.

Chang, C. L.↗

Properties of Low Tc AlMn TES

Low Tc AlMn transition-edge sensors (TESs) have been developed as sensitive thermometers for the Q-Array, which will use superconducting targets to measure the coherent elastic neutrino nucleus scattering spectrum in the RICOCHET experiment. The TESs are made of manganese-doped aluminum with a titanium and gold antioxidation layer. A prototype TES thermometer consists of two TESs in parallel, an input gold pad in metallic contact with the TESs and an output gold pad and gold thermal link meanders, which are each designed to control the flow of heat through the TESs. We have fabricated and measured low TC AlMn TES chips with or without thermal flow control structures. We present TC measurements of the TESs after the initial fabrication and further TC tuning by re-heating and summarize the thermal property studies of the prototype TES thermometer by measuring I-V curves and complex impedance.

Coherent elastic neutrino nucleus scattering, Cryo↗

First demonstration of 30 eVee ionization energy resolution with RICOCHET germanium cryogenic bolometers

The future RICOCHET experiment aims to search for new physics in the electroweak sector by measuring the Coherent Elastic Neutrino-Nucleus Scattering process from reactor antineutrinos with high precision down to the sub-100 eV nuclear recoil energy range. While the RICOCHET collaboration is currently building the experimental setup at the reactor site, it is also finalizing the cryogenic detector arrays that will be integrated into the cryostat at the Institut Laue Langevin in early 2024. In this paper, we report on recent progress from the Ge cryogenic detector technology, called the CryoCube. More specifically, we present the first demonstration of a 30 eVee (electron equivalent) baseline ionization resolution (RMS) achieved with an early design of the detector assembly and its dedicated High Electron Mobility Transistor (HEMT) based front-end electronics with a total input capacitance of about 40 pF. This represents an order of magnitude improvement over the best ionization resolutions obtained on similar phonon-and-ionization germanium cryogenic detectors from the EDELWEISS and SuperCDMS dark matter experiments, and a factor of three improvement compared to the first fully-cryogenic HEMT-based preamplifier coupled to a CDMS-II germanium detector with a total input capacitance of 250 pF. Additionally, we discuss the implications of these results in the context of the future RICOCHET experiment and its expected background mitigation performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An energy-dependent electro-thermal response model of CUORE cryogenic calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay (0νββ) in 130 Te. CUORE uses a cryogenic array of 988 TeO 2 calorimeters operated at ~10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. Further, we demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy-dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

47 OTHER INSTRUMENTATION↗

Mechanical Testing of Additively Manufactured Materials

This report summarizes research activities conducted at Argonne National Laboratory in support of the development, qualification and certification of additively manufactured (AM) metallic components to allow for innovative reactor design and licensing. In this program, AM 316L stainless steel (SS) was evaluated in both light water reactor (LWR) environments as well as at higher temperatures expected in advanced reactors.

36 MATERIALS SCIENCE↗

Viterbi decoding of CRES signals in Project 8

Abstract Cyclotron radiation emission spectroscopy (CRES) is a modern approach for determining charged particle energies via high-precision frequency measurements of the emitted cyclotron radiation. For CRES experiments with gas within the fiducial volume, signal and noise dynamics can be modelled by a hidden Markov model. We introduce a novel application of the Viterbi algorithm in order to derive informational limits on the optimal detection of cyclotron radiation signals in this class of gas-filled CRES experiments, thereby providing concrete limits from which future reconstruction algorithms, as well as detector designs, can be constrained. The validity of the resultant decision rules is confirmed using both Monte Carlo and Project 8 data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Unconventional Hysteretic Transition in a Charge Density Wave

Hysteresis underlies a large number of phase transitions in solids, giving rise to exotic metastable states that are otherwise inaccessible. Here, we report an unconventional hysteretic transition in a quasi-2D material, EuTe 4 . By combining transport, photoemission, diffraction, and x-ray absorption measurements, we observe that the hysteresis loop has a temperature width of more than 400 K, setting a record among crystalline solids. The transition has an origin distinct from known mechanisms, lying entirely within the incommensurate charge density wave (CDW) phase of EuTe 4 with no change in the CDW modulation periodicity. We interpret the hysteresis as an unusual switching of the relative CDW phases in different layers, a phenomenon unique to quasi-2D compounds that is not present in either purely 2D or strongly coupled 3D systems. Furthermore, our findings challenge the established theories on metastable states in density wave systems, pushing the boundary of understanding hysteretic transitions in a broken-symmetry state.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗